5
The functions of PAN27
:
:
:
:
1.
PAN27 can install 8 independent Relay or Dimmer dongle and can hot plugin.
2.
PAN27 can use Zigbee/Z wave USB Dongle (operational).
3.
PAN27 can control the PAN26 with RJ11 and PAN27(set as slave).
4. PAN27 each relay dongle can bear current 5A
5.
PAN27 each dimmer dongle can bear current 0.7A
The key on the body
TEMP key
:
For safety issue, you must close the top cover and start to work. When you open the
cover, TEMP key will be trigger and all module will be off and cannot be controlled
until you close the cover.
Reset key:
You can reset all the PAN27 parameter include Z-Wave/Zigbee device by press by
press 5 seconds
The external Switch
Relay dongle can connect the wall switch as Edge/Pulse/Toggle mode
Each dongle can detect the loading. When detect is overload, the module switch will
be set to off and no more current.
About LED indicator, if no module, LED is off.
When the dongle with current, the LED will be on/green.
When the dongle without current, the LED will be off/red.
How to add the device
You can insert the dongle or use Zigbee/Z-Wave to add the device.
The dongle will show on main screen directly and you can press to do actions
like Relay on/off, Dimmer adjust moving.
If you are using Zigbee/Z-Wave device, you can press the + and set PAN27 into
inclusion mode the press the device temper key to add to PAN27.
The detail operation of the device, you should refer the manual of the device.
Gateway WIFI Setting
Go to Setting Tab and click “Gateway Information”, then press icon.
The default is AP mode and if you want use STA mode please do as step by step.
Programming
When installing the relay dongle, it is necessary to set it in groups of two and insert it
in the specified grouping position.
Ontology button:
TEMP key:
In the normal working mode, the cover needs to be closed. For safety
reasons, when the cover is opened, the TEMP key will turn off the full
Module and will not accept any control until the cover is attached.
Learn key:
press three times include / press five to exclude
Reset key:
reset the set value
External Key Switch
:
:
:
:
PAN27 can connect 12 groups of manual switches, which are 8 groups of control
switches and 4 groups of situational switches.
When the corresponding module of the control switch is the Relay Module, it can be
set to Edge mode, Pulse mode or Edge-Toggle mode. The Default value is Edge-