Troubleshooting

 

Symptom

 

Cause of Failure

 

Recommendation

 

The Switch not working and 
LED off

 

1.

 

The Switch is not connect 
to the Main power

 

2.

 

The Switch break down

 

1.

 

Check power connections

 

2. Don’t open up the Switch and send 

it for repair.

 

The Switch LED 
illuminating, but cannot 
control the ON/OFF

 

Switch of the load attached

 

Check if the load connect 
into the Switch has its own 
ON/OFF switch

 

Set the ON/OFF switch of the load 
attached to ON

 

The Switch led illuminating, 
but the Detector cannot 
control the Switch

 

1. Not carry out association

 

2. Same frequency 

interference

 

1. Carry out association

 

2. Wait for a while to re-try

 

LED keep flashing 
continuously, but cannot 
control

 

Overload occurs

 

Remove the load attached or check 
max. load cannot exceed 85°C   
(230Vac/120Vac) (Resistive load)

 

 
Installation Steps

 

1. Connect PAN35 to AC N and L and COM connect to L.

 

2. Connect Load1 and Load2 to NO1 and NO2.

 

3. Connect external Switch to S1 and S2.

 

 

Fig 1. Assembling 

 

 

 

For Instruction to http:// www.philio-tech.com

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 

 

 

DANGER

 

     

Danger of electrocution!

 

 

All works on the device may be performed only by a qualified and licensed 

electrician. Observe national regulations. 

 

Any works introducing changes into the configuration must be always 
performed with disconnected voltage. 

 

 

Choosing a Suitable Location

 

1. Do not locate the Module facing direct sunlight, humid or dusty place.

 

2. The suitable ambient temperature for the Module is 0°C~40°C.

 

3. Do not locate the Module where exists combustible substances or any source     
of heat, e.g. fires, radiators, boiler etc.

 

4.  After  putting  it  into  use,  the  body  of  Module  will  become  a  little  bit  hot  of  which 

phenomenon is normal.

 

Summary of Contents for PAN35

Page 1: ...installing the unit in storming or raining weather Be sure to isolate or switch off power source before installing or maintenance Do ensure that the power supply circuit protected by a 16A circuit breaker or suitable equivalent fuse IMPORTANT Installation must be performed by skilled technicians who are informed about the standards and technical requirements of the appliance and its proper install...

Page 2: ...ed or check max load cannot exceed 85 C 230Vac 120Vac Resistive load Installation Steps 1 Connect PAN35 to AC N and L and COM connect to L 2 Connect Load1 and Load2 to NO1 and NO2 3 Connect external Switch to S1 and S2 Fig 1 Assembling For Instruction to http www philio tech com DANGER Danger of electrocution All works on the device may be performed only by a qualified and licensed electrician Obs...

Page 3: ...itch can be used for inclusion or exclusion for 3 minutes after power up Pressing Include button of PAN35 three times within 2 seconds will enter exclusion mode Node ID has been excluded 2s On 2s Off No node ID Reset Pressing Include button of PAN35 three times within 2 seconds will enter inclusion mode One press one flash Within 1 second press Include button of PAN35 again for 5 seconds IDs are e...

Page 4: ... Report OFF Command Class Switch Binary Switch Binary Report Value 0 0x00 Report ON Command Class Switch Binary Switch Binary Report Value 255 0xFF 1 2 BASIC_SET SWITCH_BINARY_SET Since the switch has two relay both the load attached to the Switch will turn on or off upon receipt of the following commands from a Z Wave Controller Command Class Basic Basic Set Value 1 99 255 0xFF both the load atta...

Page 5: ...when endpoint set to 1 PAN35 will reply ON 0xFF when Relay 1 is ON report OFF 0x00 when Relay 1 is OFF If endpoint set to 2 PAN35 will reply state of Relay2 Below is an example show a source endpoint 5 send a Get command to PAN35 endpoint 1 COMMAND_CLASS_MULTI_CHANNEL MULTI_CHANNEL_CMD_ENCAP Source End Point 0x05 this is the endpoint of command owner here we assume endpoint is 5 if the owner doesn...

Page 6: ...ge Toggle mode 2 Restore switch state mode 1 0 2 1 0 Switch off 1 Last switch state 2 Switch on 3 1 External switch mode Manual switch S1 and S2 can set to Edge mode or Pulse mode or Edge Toggle mode default value is Edge mode Edge mode this mode is suitable for the bi stable wall switch that has indicator point on the switch and the same position correspond to same state of relay1 and relay2 if t...

Page 7: ...hout the EU To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and collection systems or contact the retailer where the product was purchased They can take this product for environmental safe recycling Philio Technology Corporation...

Page 8: ...erference that may cause undesired operation FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment This transmitter must not be co located or operating in conjunction with any other antenna or transmitter 警語 警語 警語 警語 取得審驗證明之低功率射頻器材 非經核准 公司 商號或使用者均不得擅自變更 頻率 加大功率或變更原設計之特性及功能 低功率射頻器材之使用不得影響飛航安全...

Reviews: