Adding to Z-Wave

TM

 Network

 

In the front casing, there is an on/off button with LED indicator below which is used 
to toggle switch on and off or carries out inclusion, exclusion, reset or association. 
When first power is applied, its LED flashes on and off alternately and repeatedly at 
2 second intervals. It implies that it has not been assigned a node ID. 

 

 
The table below lists an operation summary of basic Z-Wave functions. Please refer 
to the instructions for your Z-Wave

TM

 Certificated Primary Controller to access the 

Setup function, and to include/exclude/

reset 

devices

 

 

Function

 

Description

 

LED Indication

 

No node ID

 

The Z-Wave Controller does not allocate 
a node ID to the Switch.

 

2-second on, 2-second off

 

Add

 

(Inclusion)

 

 
 
 

Have Z-Wave Controller entered 
inclusion mode.

 

One press one flash

 

 

To support handling of the 

device when already installed 
the external switch can be 
used for inclusion or 
exclusion for 3 minutes after 
power up.

 

Pressing Include button of PAN35 three 
times within 2 seconds will enter 
inclusion mode.

 

 

SmartStart

 

 
 
 
 
 

1. To initiate the SmartSart process, 

please type in the first five digits of 
DSK string or scan the QR code. The 
QR Code can be found on PAN30 or 
in the box. Ex:

 

DSK:    18112-24021-58001-62259-

 

57092- 27453-08187-47408

 

2. PAN30 is supported with SmartStart, it 

can be added to Z-Wave™ network by 
scanning the Z-Wave™ QR code on 
the product.

 

3. Without further actions, PAN30 will be 

automatically included in a certified 
Z-Wave™ Controller with SmartStart 
inclusion ability in 10 minutes after it 
turned on.

 

 

Remove

 

(Exclusion)

 

Have Z-Wave Controller entered 
exclusion mode.

 

One press one flash 

 

To support handling of the 

device when already installed 
the external switch can be 
used for inclusion or 
exclusion for 3 minutes after 
power up.

 

Pressing Include button of PAN35 three 
times within 2 seconds will enter 
exclusion mode.

 

Node ID has been excluded.

 

2s On, 2s Off (No node ID)

 

Reset

 

Pressing Include button of PAN35 three 
times within 2 seconds will enter 
inclusion mode.

 

One press one flash

 

Within 1 second, press Include button of 
PAN35 again for 5 seconds.

 

IDs are excluded.

 

2s On, 2s Off (No node ID)

 

 

Adding

 a node ID allocated by Z-Wave Controller means inclusion.   

Removing

 a node

 

ID allocated by Z-Wave Controller means exclusion.

 

 

Failed or success in including/excluding the node ID can be viewed from the Z-Wave 

Controller.   

 

Sometimes people are not easy to execute exclusion or inclusion especially when 

PAN35 already installed in a wall box. To solve this issue, PAN35 support a special 
feature that can use S1 or S2 to execute “exclusion, inclusion, Reset” at the first 3 
minutes when first time connect to main power. 

 

 
LED Indication 

 

There is a LED for identify function in the front case. PAN35 support the 

 

indicator ID 0x50 (Identify) and Properties ID 0x03, 0x04 and 0x05.

 

To distinguish what mode the switch is in, view from the LED for identification.

 

 
State Type

 

LED Indication

 

Normal

 

Whenever we switch On and off of the PAN35 by S1 S2 or On/Off 
button or RF command, the LED will lights up 1 second and then off.

 

No node ID

 

Under normal operation, when the Switch has not been allocated a 
node ID, the LED flashes on and off alternately at 2-second intervals. 
By pressing S1 S2 or On/Off button, it will stop flashing temporarily.

 

Learning

 

When PAN35 is in learning mode, LED flashes on and off

 

alternately and repeatedly at 0.5 second intervals.

 

Overload

 

When overload state occurs, the Switch is disabled of which LED

 

flashes on and off alternately at 0.2 second intervals. Overload

 

state can be cleared by disconnect and reconnect the Switch to

 

the main power.

 

 

 
 
 
 
 

Summary of Contents for PAN35

Page 1: ...installing the unit in storming or raining weather Be sure to isolate or switch off power source before installing or maintenance Do ensure that the power supply circuit protected by a 16A circuit breaker or suitable equivalent fuse IMPORTANT Installation must be performed by skilled technicians who are informed about the standards and technical requirements of the appliance and its proper install...

Page 2: ...ed or check max load cannot exceed 85 C 230Vac 120Vac Resistive load Installation Steps 1 Connect PAN35 to AC N and L and COM connect to L 2 Connect Load1 and Load2 to NO1 and NO2 3 Connect external Switch to S1 and S2 Fig 1 Assembling For Instruction to http www philio tech com DANGER Danger of electrocution All works on the device may be performed only by a qualified and licensed electrician Obs...

Page 3: ...itch can be used for inclusion or exclusion for 3 minutes after power up Pressing Include button of PAN35 three times within 2 seconds will enter exclusion mode Node ID has been excluded 2s On 2s Off No node ID Reset Pressing Include button of PAN35 three times within 2 seconds will enter inclusion mode One press one flash Within 1 second press Include button of PAN35 again for 5 seconds IDs are e...

Page 4: ... Report OFF Command Class Switch Binary Switch Binary Report Value 0 0x00 Report ON Command Class Switch Binary Switch Binary Report Value 255 0xFF 1 2 BASIC_SET SWITCH_BINARY_SET Since the switch has two relay both the load attached to the Switch will turn on or off upon receipt of the following commands from a Z Wave Controller Command Class Basic Basic Set Value 1 99 255 0xFF both the load atta...

Page 5: ...when endpoint set to 1 PAN35 will reply ON 0xFF when Relay 1 is ON report OFF 0x00 when Relay 1 is OFF If endpoint set to 2 PAN35 will reply state of Relay2 Below is an example show a source endpoint 5 send a Get command to PAN35 endpoint 1 COMMAND_CLASS_MULTI_CHANNEL MULTI_CHANNEL_CMD_ENCAP Source End Point 0x05 this is the endpoint of command owner here we assume endpoint is 5 if the owner doesn...

Page 6: ...ge Toggle mode 2 Restore switch state mode 1 0 2 1 0 Switch off 1 Last switch state 2 Switch on 3 1 External switch mode Manual switch S1 and S2 can set to Edge mode or Pulse mode or Edge Toggle mode default value is Edge mode Edge mode this mode is suitable for the bi stable wall switch that has indicator point on the switch and the same position correspond to same state of relay1 and relay2 if t...

Page 7: ...hout the EU To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and collection systems or contact the retailer where the product was purchased They can take this product for environmental safe recycling Philio Technology Corporation...

Page 8: ...erference that may cause undesired operation FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment This transmitter must not be co located or operating in conjunction with any other antenna or transmitter 警語 警語 警語 警語 取得審驗證明之低功率射頻器材 非經核准 公司 商號或使用者均不得擅自變更 頻率 加大功率或變更原設計之特性及功能 低功率射頻器材之使用不得影響飛航安全...

Reviews: