instant power consumption to Group1 node every 1 hour. The maximum inter-

val   to   report   its   instant   power   consumption   is   45   hours

(5s*32767/3600=45hr). When the setting is 0, PAN38 will disable Watt auto

report function. The default value is 720.

3-2 KWH Meter Report Period:

If the setting is configured for 1hour (set value =6), PAN38 will report its Ac-

cumulated   Power   Consumption   (KWh)   to   Group1   node   every   1   hour.  The

maximum interval to report its Accumulated Power Consumption (KWh) is

227.55 days (10min*32767/1440=227.55 days). When the setting is 0, PAN38

will disable KWH auto report function. The default value is 6.

3-3 Threshold of current for Load Caution

This is a warning when the current of load over the preset threshold value, if

the setting value is 1300, when the load current of Relay1 over this value,

PAN38 will send current meter report to warn the Group1 node, the range of

the setting value is from 10 to 1300, and the default value is 1300.

3-4 Threshold of KWh for Load Caution

This is a warning when the KWh of load over the preset threshold value, If the

setting value is 10000, when the Accumulated Power Consumption of Relay1

over   this   value,   PAN38   will   send   KWH   meter   report   to   warn   the   Group1

node, minimum value is 1KWh and default value is 10000 kWh.

3-5 Restore switch state mode:

 Whenever the AC power return from lost, PAN38 will restore the switch state

which could be SWITCH OFF

LAST SWITCH STATE

SWITCH ON. The

default setting is LAST SWITCH STATE.

3-6 Mode of switch off function:

 

When the mode of switch On/Off is set to 0, any command of switch off will be

disabled and the On/Off function of include button will be disabled. The default

setting is enable mode. When manual On/Off function is disabled, the RF com-

mand can only switch On but not Off. This is useful function for keeping the de-

vice in switch on state.

3-7 LED indication mode: The default setting is Show Switch State.

3-7-1 Show Switch State

When switch is on, LED is on. When switch is off,

LED is off. 

3-7-2 Show Night mode

When switch is on, LED is off. When switch is off,

LED is on.

3-7-3 One Flash mode

When the state of switch changes, LED will be on

only one second, then LED keeps off.

3-8 Watt differential mode

The default setting is 1 (= 5%).

 Whenever Watt value of PAN38 changes over 5% of last reading value, it will

send Meter report to the group 1 nodes. However, if Watt differential mode as

0, the unsolicited report will be disabled.

 

3-9 

Switch status report mode:  

The default setting is 1(Enable)

      Whenever PAN38 manually switch on or off, it will send BINARY_SWITCH_

       REPORT to the node of group1, disable when this config set to 0.

4.

Firmware update over the air (OTA)

PAN38 is based  on 700 series SoC and  supports Firmware Update Command

Class, it can receive the updated firmware image sent by controller via the Z-

wave RF media. It is a helpful and convenient way to improve some function if

needed.

5.

The Switch supports Command Classes including…

Command Class

Version

Required Security Class

Z-Wave Plus Info

2

None

Security 0

1

None

Security 2

1

None

Supervision

1

None

Transport Service

2

None

Summary of Contents for PAN38

Page 1: ...to normal status Specification Operating Voltage 100V 240V 50Hz 60Hz Maximum Load Ampere 13A Resistive load PAN38 1 PAN38 2 PAN38 3 Maximum Load Ampere 10A Resistive load PAN38 4 Switzerland Socket Type Germany type PAN38 1 France type PAN38 2 UK type PAN38 3 Switzerland type PAN38 4 Range Minimum 40 m in door 100m outdoor line of sight Operating Temperature 0 C 40 C Frequency Range 868 40MHz 869 ...

Page 2: ... putting it into use the body of Module will become a little bit hot of which phenomenon is normal Warning 1 Plug out to disconnect from power supply Do not plug in line 2 Do not exceed the max rating Warnung 1 Trennen Sie das Gerät von der Stromzuführung Verwenden Sie das Gerät nicht mit einem DIP Schalter 2 Achten Sie darauf dass die maximale Spannung niemals überschritten wird Warnung für zwisc...

Page 3: ...ion Annotation No node ID The Z Wave Controller does not al locate a node ID to the Switch LED 2 second on 2 second off Add 1 Put your Z Wave controller into inclusion mode by following the instructions provided by the controller manufacturer 2 Pressing On Off button three times within 2 seconds will enter inclusion mode Remove 1 Put your Z Wave controller into exclusion mode by following the inst...

Page 4: ...facing direct sunlight humid or dusty place 2 The suitable ambient temperature for the Switch is 0 C 40 C 3 Do not locate the Switch where exists combustible substances or any source of heat e g fires radiators boiler etc 4 After putting it into use the body of Switch will become a little bit hot of which phenomenon is normal Installation 1 Plug this On Off Switch into a wall outlet near the load ...

Page 5: ...Auto report to Grouping 1 Maximum Node 5 2 1 1 On Off Event Report When on or off state has been changed it will send Binary Switch Report to the node of Grouping 1 Binary Switch Report ON Command Class Switch Binary Switch Binary Report Value 255 0xFF OFF Command Class Switch Binary Switch Binary Report Value 0 0x00 2 1 2 Instant Power Consumption vary over 5 report When the power consumption of ...

Page 6: ... Meter Value 4 0xA3 KWh Accumulated power consumption KWh Meter Value 2 65536 Meter Value 3 256 Meter Value 4 800 35 KWh 2 2 3 Clearing accumulated power consumption Whenever re start counting the accumulated power consumption is needed you can use Meter Reset Command to clear it Meter Reset Command Command Class Meter Meter Reset 2 2 4 AC load Voltage V When receiving Meter Get Command it will re...

Page 7: ...0 99 3 Z Wave s Configuration Configuration Parameter Function Size Byte Value Unit Default Description 1 Watt Meter 2 0x0000 5s 720 0 Disable Watt Report Period 0x7FFF Report 1 32767 5s 45h 2 KWH Meter Report Period 2 0x0000 0x7FFF 10min 6 0 Disable KWh Report 1 32767 10min 227days 3 Threshold of current for Load caution 2 10 1300 0 01A 1300 1300 0 01A 13A 4 Threshold of KWh for Load caution 2 1 ...

Page 8: ...etting is LAST SWITCH STATE 3 6 Mode of switch off function When the mode of switch On Off is set to 0 any command of switch off will be disabled and the On Off function of include button will be disabled The default setting is enable mode When manual On Off function is disabled the RF com mand can only switch On but not Off This is useful function for keeping the de vice in switch on state 3 7 LE...

Page 9: ...anted Security Class Meter 5 Highest granted Security Class Multi Channel Association 3 Highest granted Security Class Notification 8 Highest granted Security Class Powerlevel 1 Highest granted Security Class Version 3 Highest granted Security Class Socket Type Since the socket type for each country in Europe varies refer to the outline for each socket suited for each country as follows Germany ty...

Page 10: ... used in accordance with the instructions may cause harmful inter ference to radio communications However there is no guarantee that interference will not occur in a particular in stallation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encour aged to try to correct the interference by one ...

Reviews: