1.

 

Programming/Enter Button

 

Programming/Enter  Button  is  utilized  for  unlocking  the  door  after 

entering the user codes, clearing errors and programming the lock. 

It’s also lock button. 

 

2. Number Buttons 

Enter  the  user codes  (4-10  digits  in length)  and  program  the  lock 

via number buttons. 

 

3. Cylinder 

Lock or unlock the latch bolt by key from exterior. 

 

4. Washer 

 

Protects the lock from water damage. 

 

5. Battery Lid 

 

Slide the lid to change the batteries or access reset button. 

 

 

6. Battery Holder 

 

Uses 4 AA (1.5V) alkaline batteries. 

 

7. R Button Holder 

 

Restore default setting. 

 

8. Turn-Piece 

 

Retract/Extend the latch bolt from interior. 

 

 

 

III. Pass Code & Function Set up 

 

1. Keep the lock in the unlock position while programming. 
2.  Run  the  door-handling  identifying  process  (Refer  to  programming 

table)  before  function  set  up  when  installing  for  first  time  or 

restoring default setting. 

3.  Please  change  default  Programming  Code  (0000)  and  User  Code 

(1234) when setting up for the first time. 

4. LED flashes orange slowly while programming. Upon a correct input, 

LED flashes green twice with 2 long beeps. LED flashes red 3 times 

    with  3  beeps  when  incorrect  input.(  If  a  mistake  is  made  during 

programming,  wait  for  6  seconds  or  press  programming  button  to 

clear then program again.) 

5. Do not pause longer than 6 seconds while programming or you will 

need to start again. 

6. You can lock/unlock this product by either key override or user code. 

Please refer to the following programming table for function set up. 

 

 

Summary of Contents for PSA01

Page 1: ... seconds Refer to 17 3 5 LED flashes orange 3 times when system has been restored to default setting 3 6 LED flashes orange slowly while in programming mode 4 Audio Indicator 4 1 1 beep sound indicates a successful operation 4 2 2 long beeps indicates a successful programming 4 3 3 beeps indicate an operation error 4 4 3 long beeps indicate that system has been restored to default setting 4 5 5 be...

Page 2: ...eset same number as Disposal User Code 10 3 To create a Disposable User Code you need to enter the Programming Code 11 Restore Preset Factory Code 11 1 You can restore the lock to the Factory default codes by pressing R button on the interior receiver module below the batteries if you forget the Programming Code or you want to cancel all previous settings 11 2 After resetting the Programming Code ...

Page 3: ...abling mute if it is not necessary 16 3 The motor sound cannot be muted 17 Code Protection Function 17 1 The lock will go into lockout mode after 5 incorrect usercode entries in a row Lock Out mode will expire after 45 seconds 18 Illumination 18 1 The LED Keypad will light up when pressing any button for ease of use in the dark 19 Include Exclude To Z WaveTM Network 19 1 After installing the PSA01...

Page 4: ...ace and the center of the door edge 2 Drill Holes Using the marks as a guide to drill a hole 2 1 8 54mm through the door face for the lockset then a hole of 1 25 4mm for latch 3 Install Latch a Insert the latch and ensure it is paralleled to the door face Mark the outline of the faceplate then take out the latch b Chisel 1 8 3mm deep along the outline to allow the faceplate to be aligned with the ...

Page 5: ...use tapping screws for metal door 4 Install Strike 5 Install Keypad Assembly a Ensure that the latch bolt is retracted b Please refer to the diagram below for Cylinder Installation Place deadbolt against keypad with tailpiece in horizontal position inserted through hub of the latch c Pass the IC wire under the latch to the interior side of the door 6 Install Inside Mounting Plate Pass the IC wire ...

Page 6: ...degrees when it s right handed door Turn the turn piece to right for 45 degrees when it s left handed door 9 Install Receiver Module a Remove the battery cover push it up and pull it out b Connect the IC wire and ensure the tailpiece is engaged with turn piece then attach receiver module to the door with screws It s optional to use wood screws Wood screws only for wood door c Insert 4 AA 1 5V alka...

Page 7: ...nction Set up 1 Keep the lock in the unlock position while programming 2 Run the door handling identifying process Refer to programming table before function set up when installing for first time or restoring default setting 3 Please change default Programming Code 0000 and User Code 1234 when setting up for the first time 4 LED flashes orange slowly while programming Upon a correct input LED flas...

Page 8: ...r the first time or if default settings are restored 2 Add New User Code Remark Up to 6 User Codes can be saved User Code should be 4 10 digits in length 3 Delete An Existing User Code 4 Delete All User Code At Once Remark Auto locking and keypad locking functionality will be invalid when User Codes are deleted The Lock can only be operated by key override during that time 5 Change Programming cod...

Page 9: ... run the door hand identifying process before re programming VI Z Wave function Function Description Include 1 Have Z WaveTM Controller entered inclusion mode 2 Press the Include Exclude function in part V 11 section 3 If included successfully it will beep twice and LED flashes green twice Exclude 1 Have Z WaveTM Controller entered exclusion mode 2 Press the Include Exclude function in part V 11 s...

Page 10: ...device will not function Result will show in Z WaveTM Controller log IX Security Network The device supports the security function When the device is included with a security controller the device will auto switch to the security mode In the security mode the follow commands need to use Security CC wrapped to communicate otherwise it will not response COMMAND_CLASS_VERSION COMMAND_CLASS_DOOR_LOCK ...

Page 11: ...mes and three short beeps are heard Cause Wrong door handling or door handling in the memory was changed Solution Press the R button to restore the system to factory default setting and re execute door handling identifying process 4 Although the first execution of the door handling identifying process succeeded the latch does not work It seems that the motor runs but the latch bolt is stuck and th...

Page 12: ... inspection and maintenance 7 While the door is closed you hear the latch bolt coming out when you press the programming button to lock the door however three short beeps are heard Conversely while the door is open no beeps are heard when locking the latch bolt Cause 1 The depth of latch bolt hole is insufficient 2 The latch bolt is not aimed at the opening of the strike Solution 1 Please dig the ...