PAN03 ; PAN10 
Switch Module with meter

 

     

 

 

 

 

 

Fig 1. PAN03 Assembling

 

 
 
 
 
 
 
 

 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

Fig 2. PAN10 Assembling

 

 
This  plug-in  ON/OFF  switch  PAN03/PAN10  is  a  security  enabled  wireless  switch, 
based  on  Z-Wave  Plus  technology.  Z-Wave  Plus

TM

  enabled  devices  displaying  the 

Z-Wave Plus

TM

 logo can also be used with it regardless of the manufacturer, and can 

also  be  used  in  other  manufacturer’s  Z-Wave

TM

  enabled  networks.  Remote  On/Off 

Summary of Contents for Z-Wave Plus PAN03

Page 1: ... OFF switch PAN03 PAN10 is a security enabled wireless switch based on Z Wave Plus technology Z Wave Plus TM enabled devices displaying the Z Wave Plus TM logo can also be used with it regardless of the manufacturer and can also be used in other manufacturer s Z Wave TM enabled networks Remote On Off ...

Page 2: ...tton on the Switch The table below lists an operation summary of basic Z Wave functions Please refer to the instructions for your Z Wave TM Certificated Primary Controller to access the Setup function and to include exclude associate devices Function Description Annotation No node ID The Z Wave Controller does not allocate a node ID to the Switch 2 second on 2 second off Inclusion 1 Put your Z Wav...

Page 3: ...tors boiler etc 4 After putting it into use the body of Switch will become a little bit hot of which phenomenon is normal Installation 1 Put the in wall switch into a wall box and connect the AC power wire L N to PAN03 PAN10 connector L N 2 Connect the wall switch to the PAN03 PAN10 as Fig1 3 There are 3 mode PAN03 PAN10 can be configured to match different kind of wall switch please refer to 3 10...

Page 4: ... 0x02 Size 4 Meter Value W 2 1 3 Overload alarm report When PAN03 PAN10 detects the current is more than 12A it will send Alarm Report to Group 1 node The content of Alarm Report Alarm report command Command_Class_Alarm Alarm_Report Alarm Type 0x08 Alarm Level 0xFF 2 2 Response to Meter Get Command The Switch will report its 1 instant Power Consumption Watt or 2 accumulated power consumption KWH o...

Page 5: ...alue 2 230 5 V 2 2 5 AC load current I When receiving Meter Get Command it will report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x05 I Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 2 Scale 0x05 Size 2 Meter Value I Example Scale 0x05 I Precision 2 Size 2 2 Bytes of I Meter Value 1 0x01 I Meter Value 2 0x...

Page 6: ...Threshold of KWh for Load Caution This is a warning when the KWh of load over the preset threshold value if the setting value is 10000 when the Accumulated Power Consumption of Relay1 over this value PAN03 PAN10 will send KWH meter report to warn the Group1 node minimum value is 1KWh and default value is 10000 kWh 3 5 Restore switch state mode Whenever the AC power return from lost PAN03 PAN10 wil...

Page 7: ...earn function does not change because learning will not be protected 5 Firmware update over the air OTA PAN03 is based on 500 series SoC and supports Firmware Update Command Class it can receives the updated firmware image sent by controller via the Z wave RF media It is a helpful and convenient way to improve some function if needed 6 Command Classes The Switch supports Command Classes including ...

Page 8: ...g it into use the body of Module will become a little bit hot of which phenomenon is normal Warning 1 Plug out to disconnect from power supply Do not plug in line 2 Do not exceed the max rating Disposal This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled waste dis...

Page 9: ...on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation...