P O W E R   D I S T R I B U T I O N   P A N E L S   S E R I E S   2 0 0

INSTRUCTION  MANUAL

INTRODUCTION

The Power Distribution Panels Series STV 200 are designed for the distribution and 

protecting of the electrical 12/24V DC system. At the front panel there are circuit breakers,

control switches, monitoring displays and sockets (depending on type). 

Each circuit is switched and protected by a thermical circuit breaker with rocker switch. 

It`s integrated light diode is showing the circuit status. In case of a short, the breaker 

switches automatically off and the light goes off. 

Some models are equipped with additional battery voltage meters and/or tank gauges. 

The additional current meters inform about the actual flowing discharge current. 

Each panel comes with a set of self-adhesive labels, which can be placed at each circuit

breaker on the signed fields.

The Power Distribution Panels Series STV 200 can only be used at low voltage DC 10-28V.

They were designed for use on yachts or camper vans and must be used in an enclosed

environment which is protected against rain, moisture, dust and condensation. 

Do not use the Power Distribution Panels Series STV 200 in places where there could be

danger of explosion by gas or dust. They`re not designed to be installed outside!

philippi elektrische systeme gmbh

www. philippi-online.de

Neckaraue 19

info@philippi-online.de

D-71686 Remseck am Neckar

Telefon: +49 (0)7146/8744-0, Fax -22

Summary of Contents for STV 200 Series

Page 1: ...tzlichen Stromanzeigen geben Aufschluß über den aktuell fließenden Entladestrom Die einzelnen Stromkreise werden auf der Frontseite mit den beiliegenden Stromkreiskenn zeichen durch Aufkleben in die dafür vorgesehenen Felder beschriftet Die Stromkreisverteiler Serie STV 200 können nur an DC Kleinspannung 10 28 V betrieben werden Sie sind zum Einsatz auf Yachten oder in Wohnmobilen konstruiert und ...

Page 2: ...als auch die Bedingungen und Methoden bei Installation Betrieb Verwendung und Wartung des Stromkreisverteilers können von philippi elektrische systeme gmbh nicht überwacht werden Daher übernehmen wir keinerlei Verantwortung und Haftung für Verluste Schäden oder Kosten die sich aus fehlerhafter Installation und unsachgemässen Betrieb entstehen GARANTIE Wir leisten aufgrund unserer Allgemeinen Gesch...

Page 3: ...ängern darf der Kabelquerschnitt der am Stromkreisverteiler montierten Zuleitung nicht unterschritten werden Brandgefahr Die Zuleitung muss an der Batterie über eine dazwischengeschaltete zum Zuleitungsquerschnitt richtig dimensionierte Hochstromsicherung angeschlossen werden Die Verbraucherabgangsleitungen werden an den Steck bzw Schraubkontakten der Sicherungsautomaten angeschlossen Die schwarze...

Page 4: ... I L E R S E R I E 2 0 0 Anschluss des Stromkreisverteilers an die Batterie Belegung der Messinstrument Anschlüsse Minus Batterie Stromversorgung 12 24V B Beleuchtungsspannung 12 24V S Eingang Tankgeber 10 180 Ohm TGT TGW UTN Seite 4 ...

Page 5: ...nd Werden zwei getrennte Seitenlaternen Bb Stb verwendet muss der Jumper Brücke J1 abgezogen werden Benötigte Steuerschalter Voltmeter Umschalter 1 0 2 Best Nr 5 1808 1103 Tankgeber Umschalter 1 2 Best Nr 5 1803 1102 Beleuchtungs Schalter 0 1 Best Nr 5 1801 1102 Batt Hauptschalter FBH 1 0 2 Best Nr 5 1808 1302 Bilge Auto Man Schalter 1 0 2 Best Nr 5 1808 1103 Buglaterne Bb Buglaterne Stb Hecklater...

Page 6: ...k S T R O M K R E I S V E R T E I L E R S E R I E 2 0 0 Anschluss der Messinstrumente Ansicht des Stromkreisverteilers von hinten Seite 6 ...

Page 7: ... Steuerschalter ein und ausge schaltet werden genauso die Displaybeleuchtung für TCM und oder BCM Bitte beachten Sie dabei das die Stromzuführung abgesichert ist Seite 7 Einleiterkabel Dimensionierung nach Germanischer Lloyd Leiter zulässige empfohlene Nennstrom querschnitt Belastung stärke des Schutzschalters mm2 A A 1 5 12 10 2 5 17 16 4 23 20 6 29 25 10 40 35 16 54 50 ...

Page 8: ... I S V E R T E I L E R S E R I E 2 0 0 Eingang Ausgang Ampèremeter mit integriertem Shunt Ampèremeter mit externem Shunt Fernsteuerung und anzeige für Tiefentladeschutz TSA Anschluss der Ampèremeter und des TSA Seite 8 ...

Page 9: ...nal battery voltage meters and or tank gauges The additional current meters inform about the actual flowing discharge current Each panel comes with a set of self adhesive labels which can be placed at each circuit breaker on the signed fields The Power Distribution Panels Series STV 200 can only be used at low voltage DC 10 28V They were designed for use on yachts or camper vans and must be used i...

Page 10: ...ons and methods during installa tion using and maintenance of the distribution panel cannot be supervised by philippi electrical systems Therefore we do not take any responsibility for loss damage or costs which develop due to incorrect installation and or inappropriate enterprise WARRANTY philippi elektrische systeme gmbh grants a two year limited and not transferable warranty for the first buyer...

Page 11: ... diameter of the extension cable may not be smaller risk of fire The inlet must be attached at the battery over an inserted high current safety device dimensioned correctly to the inlet cross section The consumer outlet lines have to be attached or screwed at the stack or screwing contacts of the automatic circuit breakers The black negative conductor has to be attached to the negative pole of the...

Page 12: ...ttery Connection of the instruments minus battery power supply 12 24V B illumination 12 24V S tank sensor inlet 10 180 Ohm TGT TGW UTN Fuse size max 35A for 6 mm wire Fuse size max 50A for 10 mm wire Panel Consumer 1 Consumer 2 Consumer 3 Consumer 4 Consumer 5 Battery Minus Busbar Page 4 ...

Page 13: ...here are two separate position lights port starboard you have to remove the jumper J1 Needed switches Voltmeter switch over 1 0 2 Ord no 5 1808 1103 Tanksensor switch over 1 2 Ord no 5 1803 1102 Illumination switch 0 1 Ord no 5 1801 1102 Batt main switch FBH 1 0 2 Ord no 5 1808 1302 Bilge Auto Man switch 1 0 2 Ord no 5 1808 1103 Bowlantern Port Bowlantern Stb Stern light Anchor light Tricolour lig...

Page 14: ...suring lines tank instrument switch over for 2 sensors tank meter connection of the sensor switch off connection circuit alternative circuit breaker switch over 1 0 2 battery 1 please fuse measuring lines directly at the battery battery 2 sensor 1 sensor 2 switch over 1 0 2 instrument lights or over fuse 1A at circuit breakers busbar circuit tank instruments tank sensor TG connection breaker for t...

Page 15: ...pump switch over 1 0 2 bilge pump switch bilge pump Table of cable diameters The tank monitor TCM can also be switched on off by using a control switch Also the display lighting of the BCM TCM monitors can be switched by them Please pay attention that the supply wires are fused Page 7 Single conductor refering to Germanischer Lloyd Conductor Cross Recommended circuit SectionArea Current rating bre...

Page 16: ...ntegrated shunt Ammeter with external shunt Remote control for deep discharge protection TSA Connection of the ammeter and the TSA battery ammeter ammeter circuit breaker rear side circuit breaker busbar battery shunt deep discharge protection TSA push button 0 1 ord no 5 1801 1202 rd bl Page 8 ...

Reviews: