17” CDT Color Monitor 107S7
20
5. Circuit description
5-1. Micro controller and deflection circuit
Micro Controller
The micro controller(IC101) core is a 80C51 type. The micro clock frequency of 12 Mhz is derived from the
Xtal oscillator, which is running at 48MHz. The DDC interface is suitable to handle DDC2 by a modified hardware
I
2
C-bus interface .Standard high current ports,3 ADC pouts with voltage inputs and 4 static standard 8 bit DAC
outputs (low interference) and one PWM output for digital control application are implemented. The central
processing unit (CPU) manipulates operands in two memory spaces. These are the 1024byte internal data
memory(consisting of 256 bytes standard RAM and 768 bytes AUX-RAM) and 48K-byte internal program memory .
The programmemory of the SAA4849 consists of 48K bytes ROM.
The SAA4849P provides sync. Processing with full auto sync. Capability, a flexible SMPS block and an
extensive set of geometry control facilities. Further the IC generates the drive waveforms for DC coupled vertical
boosters to the TDA4863A.
H/V sync signals processor
The functions of the sync processor include polarity detection, H-SYNC & V-SYNC signals counting,
Programmable SYNC signals output, free running signal generator. Pin52/Pin53 are for the H-SYNC and V-SYNC
input.
and the polarity are setting in the positive. When no signal input, the Pin49 will output a 75Hz
V-SYNC free
run signal. The Pin18/20will output a 60KHz H-SYNC free run signal. for the monitor testing use.
Reset Circuit(pin23)
There are three ways possible to invoke a reset and initialize the SAA4849P micro controller part:
Via power-on reset circuit
Via watchdog timer overflow(only micro controller reset)
Via deflection reset after start up(only micro controller reset)
The reset pin(pin23) is connected to a Schmitt trigger for nose reduction. A reset is accomplished by holding the
Reset pin HIGH.
2.7K
R153
+
22U
C145
0.1UF
C102
x-ray protection
The x-ray ptotection(pin22) input XRAY provides a voltage detector with a precise voltage input for X-ray
protection .If the input voltage at XRAY exceeds the upper threshold for 150us to 300us,the system is forced to
shut down by switching off vertical,H-and B-drive signals. There are two different ways to handle the system in
case of XRAY occurrence:
1.If the xray latch enable bit UCXRAY[2] was set to “0” during startup the system will shut down without any
interference of the uC.The deflection controller is set to ldle mode.Restart of the system only possible due to
seitching power off/power on.
5V
RST Pin23
Summary of Contents for 107S7
Page 12: ...17 CDT Color Monitor 107S7 12 ...
Page 18: ...17 CDT Color Monitor 107S7 18 Fig 4 Fig 5 Fig 6 ...
Page 33: ...17 CDT Color Monitor 107S7 33 8 Mechanical of cabinet front dis assembly ...
Page 62: ...17 CDT Color Monitor 107S7 62 13 PCB Layout 13 1 Main PCB layout ...
Page 63: ...17 CDT Color Monitor 107S7 63 13 2 CRPC Board layout ...