DDC Instructions (Continued)
How to write DDC hex files to Monitor
Menu Configuration:
Use arrow keys to highlight "Options" under the Setup menu,
press "Enter"
Tab down to ID Serial Number, use down arrow key to place
the asterisk (*) beside "store in DEC with LSB first". Press
"control/enter" to save.
(Ensure the top asterisk (*) is beside in store in HEX with LSB
first.)
Use arrow keys to highlight "Load EDID" under the file menu,
press "Enter".
Use arrow keys to highlight "PHILIPS\", Press "Enter".
Use arrow keys to highlight "the model list under subdirect",
press "Enter".
Use arrow keys to highlight "Write EDID to EEPROM" under
the R/W menu, press "Enter".
Use arrow keys to highlight "Read from EEPROM" under the
R/W menu, press "Enter".
Use arrow keys to highlight "Edit EDID Code" under the R/W
menu, press "Enter".
Verify the ID Serial number on the screen matches the serial
number of the unit.
Verify EDID Structure Version is "Version :2, Revision :1
Press "ESC"
Use arrow keys to highlight "Quit", Press "Enter".
File
R/W
Setup
Quit
Load EDID
Write EDID to EEPROM Options
Load txt file (V1.0)
Read From EEPROM
Barcode format
Save EDID
Edit EDID Code
Save txt File
Auto Scan
Convert EDID Code
Os shell
Exit
11
12
109P2 GS3 CM25
DDC Reprogramming Instructions (for
PHILIPS models)
System Requirements
Menu Configuration:
General :
DDC Module (DDC cable), P/N = 4822 320 12004
An Intel 386 (or above) PC or compatible
DOS 6.0 or above
DDCV2A.EXE software
Connect DDC Cable between PC and Monitor.
Turn on Monitor and PC.
Access Factory Mode of monitor.
Verify Factory Mode by OSD function of monitor.
Insert diskette in Drive a: Select Run "DDCV2A F0(Zero).EXE"
or Win.
(hit the space bar once )
Verify the data and version of DDC application software.
It should be : January 31 2000
Revision 3.3
Procedure
under
DOS
Press "Enter" at the introduction screen
00MITS.HEX select for 109P20/00(MITS CRT)
File
R/W
Setup
Quit
Load EDID
Write EDID to EEPROM Options
Load txt file (V1.0) Read From EEPROM
Barcode format
Save EDID
Edit EDID Code
Save txt File
Auto Scan
Convert EDID Code
Os shell
Exit
1.How to change drive
How to select .HEX files for different Model numbers
Use arrow keys to highlight "Options" under the Setup
menu, press "Enter".
Press "F2", then press "ESC", fill in "A" or "C".
[(If your .HEX files for different Model numbers in drive "A",
then fill in "A").,
(If your .HEX files for different Model numbers in drive "C",
then fill in "C").
Normally, to read DDC data from EEPROM of Monitor is
enough.]
Press "Enter", then press "ESC"
Use arrow keys to highlight "Load EDID" under the File
menu, press "Enter"
Bring up PHILIPS\
press "Enter"
Bring up ..\
109P2 GSIII
select, press "Enter"
Bring up ..\
at this highlight area, press
"Enter", then go back to last
screen
ß
2.
example:
ß
9
Go to cover page
Forward
Back