Service Modes, Error Codes, and Fault Finding
5.
How to Navigate
With the up/down cursor keys can be used to navigate through
the menu, while with the Left/Right cursor the values can be
changed.
How to EXIT
Choose “EXIT”, and press the “OK” button. Turn “Off” the TV
via the side control key and then turn “On” the TV again.
Notes: (only applicable to xxHFL3232D/10)
•
When the Hotel mode is active, the service modes CSM,
SDM, SAM and ComPair are automatically disabled (this is
to prevent hotel guests entering Philips service modes).
•
In order to use the service modes and ComPair, Hotel
mode must be disabled.
•
To enable/disable the hotel mode, the hotel setup remote
(green remote) is needed.
31
YPBPR_PHASE
0 - 255
InValid
InValid
InValid
InValid
480i, 480p, 576i, 576p, 720p 50 Hz,
720p 60 Hz,1080i 25 Hz,1080i 30 Hz,
1080p 24 Hz,1080p 50 Hz,1080p 60 Hz
32
AUD_GAIN_LINEIN
0 - 36
22
23
23
23
Audio gain by different sources
33
AUD_GAIN_HDMI
0 - 36
22
22
22
22
Audio gain for HDMI inputs
34
AUD_GAIN_ATV
0 - 36
22
23
23
23
Audio gain for analogue TV signals
35
AUD_GAIN_DTV
0 - 36
22
22
22
22
Audio gain for digital TV signal
36
AUD_GAIN_USB
0 - 36
22
22
22
22
Audio gain for the USB input
37
AUD_LIPSYNC_SPK
-272 - +272 200
250
250
100
Audio delay to the speaker, “+” is delay, “-” is ahead. NVM value
= Delay (ms)/0.147
38
AUD_LIPSYNC_HP
-272 - +272 200
250
250
100
Audio delay to the head-phone, “+” is delay, “-” is ahead. NVM
value = Delay (ms)/0.147
39
AUD_LIPSYNC_SPDIF
-272 - +272 200
250
250
100
Audio delay to the S/P-DIF output, “+” is delay, “-” is ahead. NVM
value = Delay (ms)/0.147
40
Tuner_ID
95
95
95
95
Tuner Identification, 94: NXP 95: LG
41
OPT AV2 Scart2
0, 2
0
2
2
2
0: not available, 2: CVBS + YC
42
OPT HDMI2
0/1
1
1
1
1
On/Off
43
OPT Reset Option
0/1
Press OK
Press OK
Press OK
Press OK
after reset, should restart the set immediately
44
Esticker NVM 1
0 - 61, 255 32
32
32
32
0~61: Icon number. 255: no icon
45
Esticker NVM 2
0 - 61, 255 79
40
40
40
0~61: Icon number. 255: no icon
46
Esticker NVM 3
0 - 61, 255 87
25
25
25
0~61: Icon number. 255: no icon
47
Esticker NVM 4
0 - 61, 255 85
35
35
35
0~61: Icon number. 255: no icon
48
Esticker NVM 5
0 - 61, 255 45
45
45
45
0~61: Icon number. 255: no icon
49
Esticker NVM 6
0 - 61, 255 2
65
65
65
0~61: Icon number. 255: no icon
50
Esticker NVM 7
0 - 61, 255 58
2
2
2
0~61: Icon number. 255: no icon
51
Esticker NVM 8
0 - 61, 255 48
48
48
48
0~61: Icon number. 255: no icon
52
Esticker NVM 9
0 - 61, 255 82
58
58
58
0~61: Icon number. 255: no icon
53
Esticker NVM 10
0 - 61, 255 64
64
64
64
0~61: Icon number. 255: no icon
54
Esticker NVM 11
0 - 61, 255 86
76
76
76
0~61: Icon number. 255: no icon
55
Esticker NVM 12
0 - 61, 255 76
77
77
77
0~61: Icon number. 255: no icon
56
Esticker NVM 13
0 - 61, 255 71
71
71
71
0~61: Icon number. 255: no icon
57
Esticker NVM 14
0 - 61, 255 70
74
74
74
0~61: Icon number. 255: no icon
58
Esticker NVM 15
0 - 61, 255 74
78
78
78
0~61: Icon number. 255: no icon
59
Esticker NVM 16
0 - 61, 255 72
70
70
70
0~61: Icon number. 255: no icon
60
Esticker NVM 17
0 - 61, 255 78
72
72
72
0~61: Icon number. 255: no icon
61
Esticker NVM 18
0 - 61, 255 255
255
255
255
0~61: Icon number. 255: no icon
62
Esticker NVM 19
0 - 61, 255 255
255
255
255
0~61: Icon number. 255: no icon
63
Esticker NVM 20
0 - 61, 255 255
255
255
255
0~61: Icon number. 255: no icon
64
Esticker Reset
Press OK
Press OK
Press OK
Press OK
Executing this resets the e-sticker
65
Exit_Factory Press
OK
Press
OK
Press OK
Press OK
Exit factory mode
Number
Action Items
Range
Default Value
Description
Smart Choice
Dali
32"
32"
42"
47"