Depart. Technical support- CM640
PROCEDURE COMPANY
RESTRICTED
PHILIPS Consumer
Communications
Centre du Mans
Service Repair Support
VY-V-640-P530
Page : 21 of 64
Langue : EN
Date : 21/07/03
8.2 RF
Test
8.2.1 The Test SIM Card “SP” must be inserted in the phone before starting the tests.
8.2.2 Set the equipment as shown on the picture in chapter 6.2
8.2.3 Set RF losses.
8.2.4 The following operations must be done:
- Synchronization/Registration
-
Call set up from the mobile
-
Voice loopback ( to check the sound quality)
- Call
release
-
Call set up from tester
-
Call release from tester
- GPRS
attach
those two operations have to be added when the radio tester
- GPRS
detach
allows it
8.2.5 The following parameters must be checked in TCH loop mode :
Emission parameters :
- Power
level
-
RMS phase error
-
Peak phase error
- Frequency
error
- Power
ramping
- Timing
Advance
Reception parameters :
- Rx
level
- Rx
quality
-
BER (Byte Error Rate)
-
FER (Frame Error Rate)
-
BLER (Block Error Rate)
(only when GPRS problems reported by the End User)
Generally the test sequences built inside the testers will be used to check the mobile. You must assess that the test
sequences limits comply with the standard specifications and defined test plan.
PHILIPS ELECTRONICS N.V. 1999
VY-V-640-P530
All rights reserved. Reproduction in whole
or in part is prohibited without the written
consent of the copyright owner.