41
Once disabled the lock (the amber LED turns
off), then you have to touch dot with the key
for a keystroke equivalent to the combination
CTRL+ALT+DEL on a keyboard.
The LED stays ON for TBD seconds and then
turns OFF.
5.16
Power adapter
Your CliniScape is delivered with a full range, IEC 601-1 medical approved, 100W full range (100-240V @ 50-60
Hz) AC power adapter. This adapter is meant for safely supplying the most power demanding CliniScape
configuration.
In fact the adapter can be used also for powering the CliniScape docking station with the following
configuration:
- MCA docked and fully ON
- MCA battery charger loaded and active
- docking station battery charger loaded and active
- USB doors (MCA + docking station) loaded with Bus powered devices
- LAN (on docking station) connected and active
In case of incorrect use, the AC adapter, as well as the CliniScape and its docking station, have power
limiting, over-current and short circuits protection.
Nonetheless, we recommend to follow the below warnings
Use only the AC adapter and power cord approved for the CliniScape or its accessories.
Use of another type of AC adapter may risk fire or explosion.
Your CliniScape will be shipped with the right power cord in use in most countries. Power
cord sets for use in other countries must meet the requirements of that country.
or find the right power cable, please consult the local Philips representatives.
When in use, place the AC adapter in an open and ventilated area, such as on a desktop or
the floor (do not use on wet surface). Do not cover the AC adapter with items that will
reduce cooling.
Pay attention that the adapter cable and the power cord are routed far from places where
they can be tripped over or stepped on.
Disconnect power cords and cables by grabbing the plug and not by pulling on the cable
itself. As you pull out the connector, keep it evenly aligned to avoid bending any connector
pins. Before you connect a cable, make sure both connectors are correctly aligned.
If you use an extension cord with your AC adapter, ensure that the total ampere rating of
the products plugged into the extension cord does not exceed the ampere rating of the
extension cable.
When using your power cord, make sure to position it around objects so it will not be cut
or punctured.
Note:
The AC adapter supplied with the CliniScape has no Power-on LED indication.
But, as also shown in the Table 4 , once the CliniScape is connected to the AC adapter, there
will be always a battery or Power LED active, even with the MCA off.
Summary of Contents for CliniScape CMCA10
Page 1: ...CliniScape MCA 104 series www fimi philips com Cliniscape Mobile Clinical Assistant ...
Page 12: ...12 2 4 Overview 2 4 1 MCA Dimensions in mm 31 5 205 265 29 5 48 5 250 ...
Page 16: ...16 Ventilation grid Battery slot USB door under cover Battery release lever under cover ...
Page 55: ...55 13 Your notes ...