Shaver

HQ8100

Corona

06/07

PRODUCT INFORMATION

General:

-  Mains operation only
-  World-wide automatic voltage selection
-  Electronic on/off button
- Washable

Safety information

-  This product meets the requirements regarding 

interference suppression on radio and TV.

-  After the product has been repaired, it should function 

properly and has to meet the safety requirements as 
officially laid down at this moment.

TECHNICAL INFORMATION

-  Voltage 

:  100 - 240 Volt / 50- 60 Hz

- Motor voltage 

: 9 Volt

-  Shaving heads 

:  HQ9 - 4222 036 11150

- SAP coding 

: HQ8100

DISASSEMBLY- AND  RE-ASSEMBLY ADVICE

Disassembly:

-  Remove shaving unit, to prevent damaging during 

repairing.

-  Remove the 2 screws on the backside of the shaver.
-  Remove the 2 screws out of the hairchamber.
-  Remove the hairchamber from the body.
-  Remove the cover.
-  Take out the basic body.
-  Remove the 3 screws on the cover side off the basic body.
-  Remove the cover from the basic body.
-  Remove the mains from the motor by turning and pulling 

the wires out of the motor.

-  Remove the driving unit by pushing the motor.

REPAIR INSTRUCTION

-  No specific issues

OPTIONAL (accessories)

-  No specific issues

Shaving Performance:

If customers complain about poor shaving performance 
of the triple-track shaving heads, replacing the driving 
unit is recommended.