Shaver
HQ8100
Corona
06/07
PRODUCT INFORMATION
General:
- Mains operation only
- World-wide automatic voltage selection
- Electronic on/off button
- Washable
Safety information
- This product meets the requirements regarding
interference suppression on radio and TV.
- After the product has been repaired, it should function
properly and has to meet the safety requirements as
officially laid down at this moment.
TECHNICAL INFORMATION
- Voltage
: 100 - 240 Volt / 50- 60 Hz
- Motor voltage
: 9 Volt
- Shaving heads
: HQ9 - 4222 036 11150
- SAP coding
: HQ8100
DISASSEMBLY- AND RE-ASSEMBLY ADVICE
Disassembly:
- Remove shaving unit, to prevent damaging during
repairing.
- Remove the 2 screws on the backside of the shaver.
- Remove the 2 screws out of the hairchamber.
- Remove the hairchamber from the body.
- Remove the cover.
- Take out the basic body.
- Remove the 3 screws on the cover side off the basic body.
- Remove the cover from the basic body.
- Remove the mains from the motor by turning and pulling
the wires out of the motor.
- Remove the driving unit by pushing the motor.
REPAIR INSTRUCTION
- No specific issues
OPTIONAL (accessories)
- No specific issues
Shaving Performance:
If customers complain about poor shaving performance
of the triple-track shaving heads, replacing the driving
unit is recommended.