Summary of Contents for Dynalite DMC2

Page 1: ...fications 8 Internal View 3 Mounting 4 Module mounting 5 DMC2 Installation Instructions Rev B Specifications subject to change without notice Dynalite manufactured by WMGD Pty Ltd ABN 33 097 246 921 Unit 6 691 Gardeners Road Mascot NSW 2020 Australia Tel 61 2 8338 9899 Fax 61 2 8338 9333 E Mail support controls philips com Web http philips com dynalite ...

Page 2: ...ser interface on the same network will turn all output lighting channels on from button 1 and off from button 4 allowing testing of network cables and terminations Advanced functions and custom presets can then be configured via the EnvisionProject commissioning software If commissioning services are required contact your local distributor for details High Voltage Insulation Test Do not Megger tes...

Page 3: ...power connection Communication bus connection Communication bus connection Surface mounting sleeve Wall mounting point Knockouts for unit supply Wall mounting point Communication bus cover Knockouts for lighting group channels High voltage barrier Data cable entry points Surface mounting sleeve For spare parts please call your nearest Philips Dynalite Customer Service Centre Communication bus conn...

Page 4: ...over and energize the device as the default factory programming is to have all channels set to 100 output Use the manual override keypad on the communication module to control individual channels This device should be de energized before terminating the control and data cables Select a suitable location This device is designed for indoor use only If installing in an outdoor location the DMC2 must ...

Page 5: ...phase for three phase supply or up to 63A for single phase to allow the device to be loaded to its maximum capacity The earth bar is located in the DMC unit near the top of the case To install the Communication Supply and Control modules 1 Connect the module ribbon cable to its respective plug 2 On the left hand side of the module there are two locating tabs which will line up with the DMC communi...

Page 6: ...plied wiring loom to the DMC2 as shown Use only the loom supplied with the unit and do not break or modify the loom in any way Make sure the labels on the loom correspond to the wiring on each module For modules requiring termination remove the black insulating caps from the loom before terminating to the load and supply modules For any module location that is not populated or does not require ter...

Page 7: ...7 DMC2 Installation Instructions Rev 03 Dimensions 380mm 15 0in 540mm 21 3in 103mm 4 1in 285mm 11 2in 440mm 17 3in ...

Page 8: ... Radio Frequency Notice This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the ins...