24
25
Triggering:
If the lock is under outside forced
lock mode, unlocking from inside will trigger
an alarm.
Alarm mode:
Continuous repeated alarms
Turning off:
The alarm can be turned off by
a successful verification method of any type
Outside forced unlock mode: inside unlocking alarm
Triggering:
The latch bolt performs abnormally
and cannot unlock or lock properly.
Alarm mode:
Continuous repeated alarms
Turning off:
Automatically turned off.
Abnormal latch bolt alarm
How to use an emergency power
When the battery voltage is insufficient, and
the door cannot be opened from the outside,
you can power up the lock through the Micro
USB interface by using a 5V power bank as
an emergency power supply. After opening
the door lock, please replace the batteries
immediately.
In case of a system crash and it's unable to
open the door from outside, please press
the Reset button and then release to let it
restart automatically.
Types of alarms and alarm modes
T
riggering:
After waking up, the system will
run an automatic examination on the battery
voltage. If the voltage is too low, the lock give
an alarm and a voice prompt of “Low battery.
Please replace all batteries”.
Alarm mode:A voice prompt of “Low battery.
Please replace all batteries” during unlocking.
Turning off:
The alarm will be automatically
turned off.
Triggering 1:
The door is pried open and the
sensor bolt pops up.
Alarm mode:
Continuous repeated alarms.
Turning off:
The alarm can be turned off
automatically or by any one of the successful
verification methods.
Triggering 2:
Outside escutcheon is pried
open and does not tightly fit with the door.
Alarm mode:
Continuous repeated alarms.
Turning off:
Auto-close, or close after one
of the successful verification methods, or
close after the normal indoor unlocking.
8 Troubleshooting
Anti-dismantle alarm
Low battery alarm, reminding you to replace the batteries in time
Emergency power interface
Reset button
Summary of Contents for EasyKey 7300
Page 1: ......