background image

10

11

How to enter into Master Mode

1

  Light  up  the       

keypad.

2

 Press [#] before inputting any other 

numbers. After hearing a voice prompt 

of "Enter master  PIN code", enter your 

master PIN code and confirm with [#]. 

Then you are in master mode.

Add a one-time User PIN Code

Delete a User Record

Delete a single User PIN Code

Delete All User PIN Codes

Add a Fingerprint

Add a Key Tag

1

Modify master PIN code 

Enter the new master PIN code and 

confirm with [#] again. Re-enter 

the same master PIN code and 

confirm with [#]. After hearing a 

voice prompt of “Succeeded”, press 

[*] to return to previous menu until 

you finally exit master mode.

Enter [1] to modify master PIN code.

Enter [#], enter master PIN code and 

confirm with [#]. 

2

Enter [#], then enter master PIN code 

and confirm with [#]. 

Enter [2] to add a user record, then enter 

[1] to add a new user PIN code, and the 

system will automatically number it and 

generate a voice prompt.

1

Enter a user PIN code of 6 to 12 digits 

and confirm with [#]. Then re-enter the 

user PIN code and confirm with [#]. After 

hearing a voice prompt of “Succeeded”, 

press [*] until you exit master mode.

User settings

Add a user PIN code

Enter [#], enter master PIN code and 

confirm with [#]. 

Enter a one-time user PIN code of 6 to 

12 digits and confirm with [#]. Then re-

enter the one-time user PIN code and 

confirm with [#]. After hearing a voice 

prompt of “Succeeded”, press [*] until 

you exit master mode.

Enter [2] to enter into user setting, then 

enter [2] again to add a one-time user PIN 

code.

2 2

Enter [#], enter master PIN code and 

confirm with [#].  

Place your finger against the sensor. 

After hearing a voice prompt of “Take 

away your finger and enroll again”, 

please take away your finger and re-

place it against the sensor. After hearing 

a voice prompt of “Succeeded”, press [*] 

until you exit master mode.

Enter [2] to add a user record, then enter 

[3] to add a user fingerprint, and the 

system will automatically number it and 

generate a voice prompt.

2

3

Enter [#], enter master PIN code and 

confirm with [#]. 

Enter [2] to add a user record, then 

enter [4] to add a user key tag, and the 

system will automatically number it and 

generate a voice prompt.

Place the key tag against the card reader 

until you hear a beep. After hearing a 

voice prompt of “Succeeded”, press [*] 

until you exit the master mode.

2

4

1 1

3

Enter [#], enter master PIN code and 

confirm with [#]. 

Enter [3] to delete a user record, then 

enter [1] to delete a user PIN code, and 

then enter [1] to delete a single user PIN 

code.

Enter a user code (code: 00-09) of 2 

digits and confirm with[#]. After hearing 

a voice prompt of “Succeeded”, press [*] 

until you exit the master mode.

Enter [3] to delete a user record, then 

enter [1] to delete a user PIN code, and 

then enter [2] to delete all user PIN 

codes. After hearing a voice prompt of 

"Succeeded", press [*] until you exit the 

master mode.

Enter [#], enter master PIN code and 

confirm with [#]. 

1

3

2

Summary of Contents for EasyKey 9000 Series

Page 1: ......

Page 2: ...es Unlock Unlock from Outside With a PIN Code With a Fingerprint With a Key Tag Card Unlock from Inside With a Rotatory Knob With a Functional Button With an Infrared Sensor Lock Auto Manual Mode Lock from Outside Lock from Inside Indoor Deadlock Mechanical Key Opening 1 Important Information 02 2 EasyKey Installation 03 3 Get to know your EasyKey 08 4 How to set up your EasyKey 09 Safety Warning ...

Page 3: ...ster PIN code immediately after finishing installing and debugging and keep the mechanical key properly Please replace all the batteries immediately if there is a low battery alarm Please make sure to correctly match the poles when installing the batteries Caution Do not place the battery near fire sources to avoid explosion Do not use any emergency power supply that does not meet the safety requi...

Page 4: ...w Tube X4 Pre install Instruction This product can be installed on 4 types of opening directions left out pull right in push right out pull and left in push Left open Right open Left in push Right in push Indoor Indoor Indoor Indoor Outdoor Outdoor Outdoor Outdoor Left out pull Right out pull 1 Please choose proper installation kit as per the door thickness 2 The default installation kit is applic...

Page 5: ...r the smart lock can be used normally Turn clockwise to install the deco cover install the battery put the battery cover back and after attach the strike the installation of the smart lock is complete To check whether if the rotary knob mechanical keys and all other components could be used normally 8 9 10 Insert the outside escutcheon connection cable and the motor cable into the corresponding so...

Page 6: ...o return to the previous menu 2 The default master PIN code is 12345678 Unlock with any of the registered identify methods Unlock with any two of the registered identify methods among PIN code Key Tag and Fingerprint General Mode Dual Verification Mode Outside Escutcheon 3 6 7 Fingerprint Sensor Keypad Mute Button Outside Forced Lock Button Lock Status Indicator Handle Card Reader Low Battery Volt...

Page 7: ...ing a voice prompt of Succeeded press until you exit master mode Enter 2 to enter into user setting then enter 2 again to add a one time user PIN code 2 2 Enter enter master PIN code and confirm with Place your finger against the sensor After hearing a voice prompt of Take away your finger and enroll again please take away your finger and re place it against the sensor After hearing a voice prompt...

Page 8: ...press until you exit the master mode 3 4 Delete a Key Tag 1 Enter enter master PIN code and confirm with Enter 3 to delete a user record then enter 4 to delete key tag record and then enter 2 to delete all key tag records After hearing a voice prompt of Succeeded press until you exit the master mode 3 4 Delete All Key Tags 2 Enter enter master PIN code and confirm with Choose the language as neede...

Page 9: ...EasyKey APP from App Stores via your phone Enter enter master PIN code and confirm with Extended Functions Attention Enter 6 to get into system query then enter 1 to get into security code query the system will broadcast the product series number automatically 6 Directly input 400 could enter into system query 1 Security Code Query Enter enter master PIN code and confirm with System Query Attentio...

Page 10: ...p and the door is open Inside Deadlock Mechanical Key Opening When the EasyKey is locked long press the CLOSE button after the indicator flashes once in red and there will be a voice prompt of Inside deadlock enabled Under inside deadlock mode all functions of the outside escutcheon will be locked If you try to wake up the system manually the keypad area will display the combination of 15937 X and...

Page 11: ...default settings 6 Other Functions Functions Unlocking from inside will trigger an alarm How to use After the door is successfully locked long press the button for 2 seconds to enter the outside forced lock mode Functions Use only one button to mute the lock by turning off the voice guide Applicable to the scenes where you don t want to disturb your family How to use 1 Mute When the system is awak...

Page 12: ...ced locking when the system wakes up the light will glow in white indicating this function is in use Mute mode indicator Inside Deadlock Indicator System Locked Indicator When the door is under inside deadlocking the digital functions of the outside escutcheon will be locked If the system wakes up manually the keypad will show the combination of 15937 X with a voice prompt of inside deadlocking en...

Page 13: ...ing is off 8 Troubleshooting Inside Unlocking Alarm Under Outside Forced Lock Low Battery Voltage Alarm reminds you of replacing the batteries in time Triggering 1 The door is pried open and the sensor latch bolt pops up Alarm mode Continuously repeated alarms Turning off The alarm can be turned off automatically or by a successful verification Triggering 2 The door is pried open and there is no c...

Page 14: ...it s impossible to open the door from outside please press the RES button and then release it to reboot automatically The lock is powered by four 1 5V alkaline batteries There are two sets of working power stations in the battery cabinet Eight batteries can put in to extend battery life and reduce battery replacement frequency The battery cabinet locates at the bottom end of the inside escutcheon ...

Page 15: ...inklijke Philips N V and are used under license This product has been manufactured by and is sold under the responsibility of Shenzhen Conex Intelligent Technology Co Ltd and Shenzhen Conex Intelligent Technology Co Ltd is the warrantor concerning this product Version 1 0 ...

Reviews: