background image

IMP ADJUSTMENT AND CONTROLS

IMPORTANT 

Due to high voltage of the iron, only the specifi ed cord sets must be used.

NOTES : 

1)  For standardisation reasons :

 

Type plate  :  No info. about the typenumber and voltage have been stamped onto the typeplate.

 

 

  When replacing the typeplate, engrave at least typenumber onto the typeplate with a sharp object.

2)  After the product had been repaired, it should function properly and has to meet the safety requirements and

 

legal regulations as laid down and offi cially established at this moment. 

ADJUSTMENTS AND CONTROLS

Thermostat

Thermostat, fi tted to the soleplate 23 has already been adjusted by the supplier and secured by glue.

To avoid mal-function of the iron, 

NEVER

 re-adjust the thermostat.

NOTE :  the thermostat can only be ordered together with the soleplate assembly 23.

Summary of Contents for ELANCE GC3006

Page 1: ...eets the requirement regarding interference suppression on radio and television TECHNICAL INFORMATION Voltage 220 240 V Frequency 50 60 Hz Power consumption 1800 W Water advice Suitable for tap water use However if the tap water in your area is very hard we advise you to mix it with a equal portion of distilled water or to use distilled water only Cleaning of the Iron Use only the Calc clean butto...

Page 2: ...ove Screw E 2x remove HANDLE 14 TANK 17 THERMOSTAT BUSH 18 remove Screw A 1x remove BACKPLATE 2 remove Screw B 2x cord clamping remove INLAY 5 remove Screw C 2x remove Screw D 2x remove DOSING UNIT 13 remove Screw E 2x remove HANDLE 14 remove Screw F 2x remove TANK 17 SHIELD 19 remove Screw A 1x remove BACKPLATE 2 remove Screw B 2x cord clamping remove INLAY 5 remove Screw C 2x remove Screw D 2x r...

Page 3: ... knob 4239 021 03140 4239 021 10050 4239 026 10150 4239 026 08280 4239 026 10030 11 12 13 14 15 Spray knob Tank seal Dosing unit Handle Rattle spring 4239 026 10080 4239 015 54400 4239 021 08510 4239 026 08050 4239 026 08840 16 17 18 19 20 Pump Tank Assy non Drip stop Thermostat bush Heat shield Cover non Drip stop 4239 020 90560 4239 022 53200 4239 015 98410B 4239 010 07850 4239 026 09750 21 22 2...

Page 4: ...EXPLODED VIEW IRON ...

Page 5: ...onto the typeplate with a sharp object 2 After the product had been repaired it should function properly and has to meet the safety requirements and legal regulations as laid down and officially established at this moment ADJUSTMENTS AND CONTROLS Thermostat Thermostat fitted to the soleplate 23 has already been adjusted by the supplier and secured by glue To avoid mal function of the iron NEVER re...