background image

FC9206

-  To open the appliance first remove the filter cover (item 31) 

and then remove the 5 screws from the appliance.

-  To remove the hinge, 

first remove the end caps 
(item 16) this can be done 
with a screwdriver, 
see picture.

-  When the end caps are 

removed, the hinging pin 
can be removed.

-  When this is done the hinge can be taken off the appliance.
-  Remove the can with the filters.
-  To remove the housing (7 screws) you will require for some 

screws a screwdriver with a 14.5 cm long shrank for this.
Screwdriver 4322 009 08490 for T15 can be used.

-  When the repair is finished, check whether all functions of 

the appliance work properly.

-  To disassemble the cord winder, use TORX screwdriver no. 

T10, which is one of a set consisting of T20; T15; T10; T9; 
T8; T7 and T6 (code number 4822 395 505145)

Further disassembly advise for the hinge:

- The chromium ornamental 

plate can be removed with 
a screwdriver (see picture) 
after that the min/max 
button and the On/Off 
button can be removed 
from the plate.

-  Remove the screw (

B

) underneath the ring with a T15 

screwdriver; the orange user panel (item 4) can be removed.

-  Choke assy can be taken out.
-  PCB can be removed.
-  To remove the sealing disk and the detector with the spring 

you have to remove the 2 screws (

C

) next to the sealing 

disk.

REPAIR INSTRUCTION

-  If the reel half spring unit is replaced, shaft 

L

 must be 

lubricated with silicone grease.  Do not apply any silicone 
grease to or spill any grease on terminals (item 46) or 
conductors (item 47).

-  The cord winder spring must be tensioned to the maximum 

level and the be rewound approx 1.5 turn.

-  Item 5, air valve, opens to cool the motor if the air 

displacement is too low or if the airflow is blocked.

-  If the function of the electronic control unit is not required, 

the Triac must be short-circuited in the manner shown in 
the circuit diagram.

ELECTRICAL DIAGRAM

DISASSEMBLY- AND  RE-ASSEMBLY ADVISE

Triac

Short-circuit

MOTOR
POWER
MODULE

Blue

Brown

CORD WINDER

Black

Blue

Brown

Black

M

Black

2-8

Summary of Contents for FC9206

Page 1: ...ack Power consumption 1800 W IEC 230V Maximum Air displacement 37 l s Vacuum 285 mbar 28 5 kPa Duststorage capacity 2 L Cord length 9 m Fiter system HEPA cyclone filtration system Permanent motor protection filter Super Clean Air HEPA12 exhaust filter Dimensions of cleaner 470 x 320 x 340 mm Dimensions of packaging 590 x 390 x 380 mm Net weight 7 2 kg ACCESSORIES Special nozzle Turbo Brush nozzle ...

Page 2: ...iver see picture after that the min max button and the On Off button can be removed from the plate Remove the screw B underneath the ring with a T15 screwdriver the orange user panel item 4 can be removed Choke assy can be taken out PCB can be removed To remove the sealing disk and the detector with the spring you have to remove the 2 screws C next to the sealing disk REPAIR INSTRUCTION If the ree...

Page 3: ...ozzle Tri active nozzle Turbo brush nozzle Pos Service code Description 1 2 3 3a 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 4322 005 18630 4322 003 25670 4322 005 17720 4322 003 25230 4322 005 17930 4322 005 17500 4322 006 22770 4322 006 23270 4322 005 17730 4322 005 19440 4322 001 73370 4322 004 20130 4322 003 26010 4322 005 17610 4322 005 17520 4322 003 25130 4322...

Page 4: ...FC9206 EXPLODEDVIEW D C C B A A E E E E E E E Black Blue Brown 2 4 6 5 7 8 3 3a 10 11 17 12 13 14 16 9 1 4 8 ...

Page 5: ...FC9206 EXPLODEDVIEW F F G G G G G G G Brown Black Blue Z X 19 21 15 22 23 26 27 18 25 37 36 35 34 33 32 31 30 24 28 20 29 5 8 ...

Page 6: ...FC9206 EXPLODEDVIEW 47 48 49 39 38 43 40 41 42 44 45 46 H K J K K H H L Black Black Z Y Black Blue X Y Brown 6 8 ...

Page 7: ...FC9206 EXPLODEDVIEW 53 60 54 55 59 58 56 57 Europe Ø 4 8mm 49 Swiss Italy 48 U K H K 52 51 50 51a 7 8 ...

Page 8: ...FC9206 EXPLODEDVIEW 8 8 ...