Service Modes, Error Codes, and Fault Finding
EN 30
FHP PDP
5.
Figure 5-20 Fault symptom overview (2/3)
E_14580_006.eps
260304
No Fault contents
Suspected fault
location
Analysis
procedure and
measure
9
Bar width of 1/8 or
multiples of 1/8 of the
screen height, is
displayed Abnormal
(Screen does light)
Panel chassis
Replace panel
chassis
10
Bar width of 1/2 of the
screen height.
Abnormal display
(Screen does not light)
Panel chassis Y-
SUS, X-SUS
Above boards
are connected
Refer to horizontal
bar.
11
Image sticking.
Burn in?
Fixed display contents
are always displayed.
Panel chassis
Perform all white
heat run. After
judgment, replace
panel chassis if
needed.
12
Stains
Oval-shaped points
having abnormal
luminance are
scattered in the upper
or lower part of screen.
Panel chassis
Perform all white
heat run. After
judgment, replace
panel chassis.
13
Twinkle
The entire screen
momentarily becomes
brighter or darker.
Poor connector
contact. Panel
chassis
14
Flicker
The entire screen
flickers continuously
Poor connector
contact. FFC
(Flat Foil
connector Cable)
Connector / cable
reconnection or
Cable Exchange
15
Luminance is
abnormal
Screen is too dark or
too bright. (Out of
specifications)
16
Chrominance is
abnormal
Colors cannot be
displayed orrectly.
LOGIC
17
Sync is
disturbed
LOGIC
Horizontal bar
Replace LOGIC
board and folow
Logic Board
echange
procedure
Fault status
burn in?