Service Modes, Error Codes, and Fault Finding
EN 10
FHP PDP
5.
5.
Service Modes, Error Codes, and Fault Finding
Index of this chapter:
5.1 Repair Tools
5.3 Process Flow
5.4 Repair Instructions
5.5 Defect Description Form
5.1
Repair Tools
To be able to repair the Plasma Display Panels on board level,
the following repair tools are available:
•
Special LVDS cable: T.B.D.
•
Foam buffers: 3122 785 90581.
Figure 5-1 Extension cable kit ALiS PDP
Figure 5-2 Foam buffers for FTV
5.2
Error codes
When an error causes the PDP to switch “OFF”, an error code
is put into an EEPROM on the Logic Board. You can read out
the contents of the error code memory with the ComPair tool.
5.2.1
How to Connect the ComPair Tool
•
Carefully disconnect the LVDS cable from CN01 on the
Logic Board.
•
If necessary connect a PSU with a voltage of 3.3V to drive
the LOGIC board.
•
Connect the cable from the ComPair tool to connector
CN01 of the LOGIC board.
•
Turn on the ComPair tool.
•
Launch the ComPair software.
•
Read out the error buffer.
5.2.2
Error Code Overview
Table 5-1 Error code table
G_16400_018.eps
270706
Power Supply
Logic Board
CN06
CN01
I
2
C
Compair
Vpr
3
SDA
GND
SCL
CN06
I
2
C
Compair
8
6
4
CN01
3k3
3k3
14
E_14580_024.eps
250304
Error code
Detected by board
Error description
Suspected board(s)
21
X-SUS
Vxx power voltage is too high
X-SUS
LOGIC
24
Vxx power voltage is too low
X-SUS
LOGIC
25
Vex power voltage is too high
X-SUS
26
Vex power startup is faulty
X-SUS
LOGIC
44
Y-SUS
Vey power voltage is too low
Y-SUS
LOGIC
45
Vey power voltage is too high
Y-SUS
46
Vey power startup is faulty
Y-SUS
LOGIC
4C
Temperature too high
Y-SUS
LOGIC
61
X-SUS
Y-SUS
Vs power voltage is too high
Y-SUS
X-SUS
LOGIC
PSU
62
Vs power startup is faulty
X-SUS
Y-SUS
PSU
LOGIC
64
Ve power voltage is too low
LOGIC
X-SUS
Y-SUS
65
Ve power voltage is too high
Y-SUS
Y-SUS
66
Ve power startup is faulty
LOGIC
X-SUS
Y-SUS
68
Vw power voltage is too low
Y-SUS
LOGIC
69
Vw power voltage is too high
LOGIC
Y-SUS
6A
Vw power startup is faulty
Y-SUS
LOGIC
79
Vw power current is too high (during operation)
Y-SUS
X-SUS
LOGIC
7B
Vs power voltage is too high (during startup)
Y-SUS
X-SUS
LOGIC