IMP ADJUSTMENTS AND CONTROLS
IMPORTANT
Due to high voltage of the iron, only the specifi ed cordsets must be used.
NOTES :
1) For standardisation reasons :
Dial
: With English/Spanish text only.
Soleplate
: Ceralon soleplate will be provided for all models.
Type plate
: No info. about the typenumber and voltage has been stamped onto the typeplate.
When replacing the typeplate, engrave at least the typenumber onto the typeplate with a sharp object.
2) Parts with numbers from 100 and higher, cannot be ordered seperately.
3) After the product has been repaired, it should function properly and has to meet the safety requirements and
legal regulations as laid down and offi cially established at this moment.
ADJUSTMENTS AND CONTROLS
Thermostat
Thermostat, fi tted to the soleplate 16 has already been adjusted by the supplier and secured by glue. To avoid mal-function of the
iron,
NEVER
re-adjust the thermostat.
NOTE : the thermostat can only be ordered together with the soleplate assembly 16.