background image

GC2860

5-5

EXPLODED VIEW

22

19

5

2

1

8

4

7

9

20

16

24

15

18

23

3

13

14

11

10

6

12

21

25

17

B

A

D1

D2

D3

C1

C2

C3

Summary of Contents for GC2860

Page 1: ...ight Product net weight 1 24 kg Water Advice In case you live in an area with hard water e g water hardness more than 8 dGH it is recommended to use a mixture of 50 tap water and 50 demineralized water Powerglide Soleplate Silver solgel coating for more robust scratch resistance smooth gliding easy to clean Pointed Tip This feature allows soleplate to reach tricky area Steam Boost The steam boost ...

Page 2: ...RINTED 17 Disassemble INLAY PRINTED 17 Disconnect 2x quick connectors of LAMP ASSY 5 Disassemble LAMP ASSY 5 THERMOSTAT DIAL PRINTED 21 WATERTANK ASSY 7 COVER 3 INSULATION SHEET 23 DOSING SEAL 13 SOS SEAL 14 SOLEPLATE MOUNTED ASSY 1 Disassemble THERMOSTAT DIAL PRINTED 21 Remove screws C 3x Disassemble WATER TANK ASSY 7 Remove screws D 3x Disassemble COVER 3 Note for re assembly Please ensure that ...

Page 3: ... minutes The table below shows the temperature requirement Marking Soleplate temperature Deg C Material for example Test point Minimum Maximum Nominal Tolerance 1 dot 70 120 95 25 Acetate elastane polyamide polyproylene 2 dots 100 160 130 30 Cupro polyester silk triacetate viscose wool 3 dots 140 210 175 35 Cotton linen 2 Leakage current Check that leakage current is within IEC requirement Measure...

Page 4: ...4239 015 58310 4239 026 34320 4239 026 34330 4239 021 51880 4239 021 51910 4239 026 34370 4239 026 34650 4239 021 53580 4239 000 08670 4239 010 10290 4239 026 34630 4239 021 50690 Soleplate mounted assy 230 V 2000 W Ryton ring Cover molded Thermostat bush Lamp assy Tank top seal Water tank assy GC2860 Australia Plastic rattle spring Spray pump SOS pump Valve bellow assy Steam shaft assy Dosing sea...

Page 5: ...GC2860 5 5 EXPLODEDVIEW 22 19 5 2 1 8 4 7 9 20 16 24 15 18 23 3 13 14 11 10 6 12 21 25 17 B A D1 D2 D3 C1 C2 C3 ...

Reviews: