background image

GC3620

REPAIR INSTRUCTIONS

-  Due to the high wattage of the iron, only the specified cord set must be used.

-  Should damage be observed on the 

CORDSET 9

, it must be replaced. 

Continued usage is not allowed.

-  For standardization reason, the 

COVER ASSY 5

 is provided without type plate information eg. type number, voltage etc.  When 

replacing the cover, engrave the type number & voltage on the type plate with a sharp object.

-  After the product has been repaired, it should function properly and has to meet the safety requirements & legal regulations as 

laid down & officially established at this moment.

-  The following tests are common checks that are conducted on a repaired product before it is returned to the consumer.

1. 

Soleplate temperature

Check that soleplate temperature is within IEC requirement.

Measure the temperature of the soleplate after the iron has reached steady state i.e connected to the mains for at least 15 minutes.
The table below shows the temperature requirement.

Marking

Soleplate temperature (Deg C)

Material, for example

Test-
point

==

Minimum Maximum N Tolerance

 (1 

dot)

  70

120

  95 ± 25

Acetate, elastane, polyamide, polyproylene

••

 (2 

dots)

100

160

130 ± 30

Cupro, polyester, silk, triacetate, viscose, wool

•••

 (3 dots)

140

210

175 ± 35

Cotton, linen

2. 

Leakage current

Check that leakage current is within IEC requirement.

Measure leakage current between LIVE/NEUTRAL & EARTH.
IEC requirement is that at 230 V supply, the EARTH leakage current must be less than 0.75 mA.

3. 

Water leakage / Functionality

Check that there is no water leakage from any part of the product during operation.

Check that the functionality of the product (product dependent) eg. steaming, variable steam, SOS, ASO etc is working properly.

4. 

Loose part

Check that there are no loose parts eg. extra screw in the product that can cause short-circuit or product malfunction.

3-5

Summary of Contents for GC3620

Page 1: ...ter advice In case you live in an area with hard water e g water hardness more than 8 dGH it is recommended to use a mixture of 50 tap water and 50 demineralised water Automatic energy saving 90 of the energy a steam iron uses is used to convert water into steam This steam iron with innovative mechanism in the handle makes sure that you still get high steam performance but with optimal use of ener...

Page 2: ...4 SUB INLAY PRINTED 22 WATER TANK HOUSING ASSY 11 SWIVEL MOULDED 7 CORDSET 9 Disassemble FILLING DOOR ASSY 24 Remove screw C Disassemble SUB INLAY PRINTED 22 Disassemble TANK TOP SEAL 17 Remove screw D1 D2 D3 Disassemble WATER TANK HOUSING ASSY 11 Disengage quick connectors of CORDSET 9 Remove screw E1 E2 Disassemble swivel column Disassemble SWIVEL MOULDED 7 Disassemble CORDSET 9 COVER ASSY 5 SOL...

Page 3: ... of the soleplate after the iron has reached steady state i e connected to the mains for at least 15 minutes The table below shows the temperature requirement Marking Soleplate temperature Deg C Material for example Test point Minimum Maximum Nominal Tolerance 1 dot 70 120 95 25 Acetate elastane polyamide polyproylene 2 dots 100 160 130 30 Cupro polyester silk triacetate viscose wool 3 dots 140 21...

Page 4: ...990 4239 021 54881 4239 021 53160 4239 026 36640 4239 026 36650 4239 026 10270 Soleplate mounted assy 230 V 2200 W Soleplate mounted assy 120 V SOS seal Ryton spacer Dosing seal Cover assy Heat shield Swivel moulded Backplate moulded Cord set EU Cord set Singapore Hong Kong Cord set Thailand Cord set Taiwan Cord set 120 V Brazil Cord set 230 V Brazil Thermostat bush Water tank housing assy Water t...

Page 5: ...GC3620 EXPLODED VIEW MAX C D1 D2 D3 F3 F2 F1 A E1 B1 E2 B2 24 17 11 8 26 19 20 21 22 6 27 5 4 3 7 9 Swivel column 25 18 2 1 10 5 5 ...

Reviews: