background image

GC4860

REPAIR INSTRUCTIONS 

-  Due to the high wattage of the iron, only the specified cord set must be used.

-  Should damage be observed on the 

CORDSET 16

, it must be replaced. 

Continued usage is not allowed.

- If 

COVER 1

 is provided without type plate information eg. type number, voltage etc. When replacing the cover, engrave the type 

number & voltage on the type plate with a sharp object.

-  After the product has been repaired, it should function properly and has to meet the safety requirements & legal regulations as 

laid down & officially established at this moment.

-  The following tests are common checks that are conducted on a repaired product before it is returned to the consumer.

1. 

Soleplate temperature

Check that soleplate temperature is within IEC requirement.

Measure the temperature of the soleplate after the iron has reached steady state i.e connected to the mains for at least 15 
minutes. The table below shows the temperature requirement.

Marking

Soleplate temperature (Deg C)

Material, for example

Test-
point

==

Minimum Maximum N Tolerance

 (1 

dot)

  70

120

  95 ± 25

Acetate, elastane, polyamide, polyproylene

••

 (2 

dots)

100

160

130 ± 30

Cupro, polyester, silk, triacetate, viscose, wool

•••

 (3 dots)

140

210

175 ± 35

Cotton, linen

2. 

Leakage current

Check that leakage current is within IEC requirement.

Measure leakage current between LIVE/NEUTRAL & EARTH.
IEC requirement is that at 230 V supply, the EARTH leakage current must be less than 0.75 mA.

3. 

Water leakage / Functionality

Check that there is no water leakage from any part of the product during operation.

Check that the functionality of the product (product dependent) eg. steaming, variable steam, SOS, ASO etc is working 
properly.

4. 

Loose part

Check that there are no loose parts eg. extra screw in the product that can cause short-circuit or product malfunction.

3-5

Summary of Contents for GC4860

Page 1: ...t Product 1 60 kg Water Advice Suitable for tap water use Advice to mix with equal portion of distilled water or use only distilled water if the tap water is very hard SteamGlide plus soleplate The specially treated SteamGlide plus soleplate is designed with 2 distinctly different types of steam vents 1 Large vents for maximum crease removel 2 Fine vents for best glide Easy Reach Steam Tip Concent...

Page 2: ...11 WATER TANK ASSY 12 HOUSING 13 THERMOSTAT BUSH 18 Remove Screw A Remove BACKPLATE 6 Remove INLAY ASSY 10 Remove SOS KNOB 14 Remove SPRAY KNOB 15 Remove THERMOSTAT PLATE PRINTED 19 Remove THERMOSTAT RING 20 Remove Screws D1 D2 Remove Screws E1 E2 Remove HOUSING 13 Remove Screws F1 F2 Remove WATER TANK ASSY 12 RYTON SPACER 3 DOSING SEAL 4 HEAT SHIELD 5 Remove Screw A Remove BACKPLATE 6 Remove INLA...

Page 3: ...e after the iron has reached steady state i e connected to the mains for at least 15 minutes The table below shows the temperature requirement Marking Soleplate temperature Deg C Material for example Test point Minimum Maximum Nominal Tolerance 1 dot 70 120 95 25 Acetate elastane polyamide polyproylene 2 dots 100 160 130 30 Cupro polyester silk triacetate viscose wool 3 dots 140 210 175 35 Cotton ...

Page 4: ...9 026 40491 4239 021 59091 4239 021 59661 4239 026 40921 4239 021 59521 4239 021 59561 4239 026 40841 4239 026 40881 4239 000 11111 4239 021 59161 4239 026 17320 4239 021 60171 4239 026 40251 4239 026 05990 Cover inscribed Soleplate mounted assy 230 V 2400 W Ryton spacer Dosing seal Heat shield Backplate Ball swivel Backplate cover Filling door assy Inlay assy Steam slider Water tank assy Housing ...

Page 5: ...GC4860 EXPLODED VIEW MAX E1 E2 D1 D2 B1 F1 F2 G1 G2 G3 B2 A 18 10 6 3 17 19 20 7 5 1 21 16 12 11 9 4 2 14 13 15 8 5 5 ...

Reviews: