background image

GC7220

7-7

-  Due to the high wattage of the iron, only the specified cord set must be used.

-  Should damage be observed on the 

HOSE-CORD ASSY 3

 or 

CORDSET 55

, they must be replaced. 

Continued usage is not allowed.

-  When replacing the 

MICROSWITCH ASSY 9

, please dress the 2 attached wires such that they are free of tension. Pulling force 

on the wires may affect the steam triggering.

-  To avoid damage to the sealing & components of the 

BOILER ASSY 38

NEVER

 clean the boiler assy with vinegar, descaling 

agent or other corrosive chemicals.

- When replacing 

ELECTROVALVE 40

 or 

PUMP ASSY 45

, please be reminded to apply loctite at the joints for good sealing.

-  After the product has been repaired, it should function properly and has to meet the safety requirements & legal regulations as 

laid down & officially established at this moment.

-  The following tests are common checks that are conducted on a repaired product before it is returned to the consumer.

1. 

Soleplate temperature

Check that soleplate temperature is within IEC requirement.

Measure the temperature of the soleplate after the iron has reached steady state i.e connected to the mains for at least 15 minutes. 
The table below shows the temperature requirement.

Marking

Soleplate temperature (Deg C)

Material, for example

Test-
point

==

Minimum Maximum N Tolerance

 (1 

dot)

  70

120

  95 ± 25

Acetate, elastane, polyamide, polyproylene

••

 (2 

dots)

100

160

130 ± 30

Cupro, polyester, silk, triacetate, viscose, wool

•••

 (3 dots)

140

210

175 ± 35

Cotton, linen

2. 

Leakage current

Check that leakage current is within IEC requirement.

Measure leakage current between LIVE/NEUTRAL & EARTH.
IEC requirement is that at 230 V supply, the EARTH leakage current must be less than 0.75 mA.

3. 

Water leakage / Functionality

Check that there is no water leakage from any part of the product during operation.

Check that the functionality of the product (product dependent) eg. steaming, variable steam, SOS, ASO etc is working properly.

4. 

Loose part

Check that there are no loose parts eg. extra screw in the product that can cause short-circuit or product malfunction.

REPAIR INSTRUCTIONS

Summary of Contents for GC7220

Page 1: ...ction properly and has to meet the safety requirements as officially laid down as this moment TECHNICAL INFORMATION Voltage 220 240 V Frequency 50 60 Hz Power Iron 800 W Boiler 1200 W Dimension F box 350 x 350 x 250 mm L x W x H Weight with packing 6 4 kg Water advice If the tap water in your area is very hard it is advisable to mix the tap water with an equal amount of demineralised water Easy to...

Page 2: ...rear HOUSING Part 2 DISASSEMBLY ADVICE IRON INLAY 4 LAMP ASSY 7 MICROSWITCH ASSY 9 TRIGGER 12 THERMOSTAT DIAL ASSY 14 HOUSING PRINTED 16 SOLEPLATE COVER 17 THERMOSTAT BUSH 19 RUBBER HOSE 20 BRASS JOINT 21 SOLEPLATE ASSY 23 Remove Screw A Disassemble BACKPLATE 1 Disassemble TRIGGER 12 Tip Disassemble TRIGGER by inserting a sharp object into the gap at the rear of the trigger prying upward Remove Sc...

Page 3: ...9 026 27340 4239 021 32580 4239 026 01220 4239 021 41970 4239 010 10110 4239 026 27330 4239 014 54370 4239 021 41030 4239 026 27380 4239 021 41150 4239 026 27300 4239 015 70150 4239 026 13220 4239 015 56530 4239 010 09350 4239 010 10280 4239 021 41290 Backplate Swivel Blue Hose cord assy Inlay Blue Lamp cover Steam lock Blue Lamp assy Lamp holder Microswitch assy Hose clip Iron Trigger Trigger spr...

Page 4: ...GC7220 4 7 EXPLODEDVIEW IRON A 3 7 Cord clamp E1 D1 D3 D2 C B1 B2 E2 E3 15 2 21 10 22 20 17 18 1 14 5 6 12 13 4 9 22 19 16 8 23 ...

Page 5: ... Disassemble BRAIDED RUBBER HOSE BOILER 41 Disassemble PUMP ASSY 45 Remove Torx screws L1 L2 L3 Disassemble TOP SPACER 48 Disassemble BOILER ASSY 38 PARTS LIST STAND Pos Service code Description 30 33 34 35 36 37 38 39 40 41 42 43 44 45 46 4239 015 56780 4239 021 39670 4239 021 42140 4239 021 40140 4239 026 26410 4239 021 41000 4239 021 39530 4239 017 10420 4239 017 09890 4239 015 56930 4239 010 1...

Page 6: ...GC7220 6 7 EXPLODEDVIEW STAND 58 F1 K1 H1 H2 K2 K4 K3 F2 G F3 30 35 40 57 56 39 38 42 48 49 46 47 59 41 33 34 36 52 45 53 51 54 53 50 55 43 44 Cord clamp Clamping plate 37 L2 L3 L1 ...

Page 7: ...1 Soleplate temperature Check that soleplate temperature is within IEC requirement Measure the temperature of the soleplate after the iron has reached steady state i e connected to the mains for at least 15 minutes The table below shows the temperature requirement Marking Soleplate temperature Deg C Material for example Test point Minimum Maximum Nominal Tolerance 1 dot 70 120 95 25 Acetate elasta...

Reviews: