background image

GC7422

2-8

BACKPLATE 21

INLAY

SOS KNOB 10

LAMP ASSY 

MICROSWITCH ASSY 4

HOSE CORD CABLE

ASSY 13

THERMOSTAT DIAL 20

HOUSING PRINTED 6

SUB-HOUSING 

STEAM DEVIATOR ASSY 12

COVER SOS MOLDED 3

SOS SEAL 11

SOLEPLATE

MOUNTED ASSY 1

Remove 

Screw A

Disassemble 

BACKPLATE 21

Disassemble 

INLAY

Disassemble 

SOS KNOB 10

Disengage 

Ribs of light ring

Disassemble 

LAMP ASSY

Remove 

Screw B

Disassemble 

Switch holder

Disassemble 

MICROSWITCH ASSY 4

Remove 

Screws C1, C2, C3

Disassemble 

HOSE CORD CABLE ASSY 13

Disassemble 

THERMOSTAT DIAL 20

Remove 

Screws D1, D2, D3, D4

Disassemble 

HOUSING PRINTED 6

Remove 

Screw E

Disassemble 

SUB-HOUSING

Disassemble 

STEAM DEVIATOR ASSY 12

Remove 

Screws F1, F2, F3

Disassemble 

COVER SOS MOLDED 3

DISASSEMBLY ADVICE - IRON

Summary of Contents for GC7422

Page 1: ...uld function properly and has to meet the safety requirements as officially laid down as this moment TECHNICAL INFORMATION Voltage 220 240 V Frequency 50 60 Hz Power Iron 800 W Boiler 1370 W Dimension F box 350 x 350 x 250 mm L x W x H Weight 6 4 kg Water advice If the tap water in your area is very hard it is advisable to mix the tap water with an equal amount of demineralised water Easy to rinse...

Page 2: ... Disassemble INLAY Disassemble SOS KNOB 10 Disengage Ribs of light ring Disassemble LAMP ASSY Remove Screw B Disassemble Switch holder Disassemble MICROSWITCH ASSY 4 Remove Screws C1 C2 C3 Disassemble HOSE CORD CABLE ASSY 13 Disassemble THERMOSTAT DIAL 20 Remove Screws D1 D2 D3 D4 Disassemble HOUSING PRINTED 6 Remove Screw E Disassemble SUB HOUSING Disassemble STEAM DEVIATOR ASSY 12 Remove Screws ...

Page 3: ...5 6 10 11 12 13 18 19 20 21 4239 021 51301 4239 015 70150 4239 026 38621 4239 021 44410 4239 026 13220 4239 021 56061 4239 026 38671 4239 015 57400 4239 021 31780 4239 021 56081 4239 026 38681 4239 014 54690 4239 021 56091 4239 026 38701 Soleplate mounted assy Ryton ring Cover SOS molded Microswitch assy Thermostat bush Housing printed SOS knob SOS seal Steam deviator assy Hose cord mounted assy T...

Page 4: ...PLODED VIEW IRON 10 20 18 6 3 1 11 Light ring Switch holder 12 5 4 21 2 13 19 F2 F1 F3 E D3 D4 D1 C1 C2 C3 A D2 B Screw Dimension A C E Ø 3 5 mm x 13 mm B D Ø 2 6 mm x 9 6 mm F1 M4 0 mm x 10 mm F2 F3 M4 0 mm x 16 mm ...

Page 5: ... Remove Screws K1 K2 K3 K4 Disconnect INLET TUBE PUMP Disconnect DE AIR TUBE Disassemble WATER TANK ASSY 34 Disassemble BRAIDED RUBBER HOSE BOILER Disassemble PUMP ASSY 45 Remove Torx screws L1 L2 L3 Disassemble TOP SPACER Disassemble BOILER ASSY 38 PARTS LIST STAND Note For Pos 45 please replace both components together when either one is faulty The 2 components come as a service kit Pos Service ...

Page 6: ...GC7422 6 8 EXPLODED VIEW STAND F1 K1 H1 H2 K2 K4 K3 F2 G F3 40 56 38 42 34 36 52 50 65 55 44 45 Cord clamp Clamping plate 37 L2 L3 L1 30 33 58 67 ...

Page 7: ...ed to the consumer 1 Soleplate temperature Check that soleplate temperature is within IEC requirement Measure the temperature of the soleplate after the iron has reached steady state i e connected to the mains for at least 15 minutes The table below shows the temperature requirement Marking Soleplate temperature Deg C Material for example Test point Minimum Maximum Nominal Tolerance 1 dot 70 120 9...

Page 8: ...GC7422 8 8 REPAIR INSTRUCTIONS Pump Assy Wire connections Connector positions in DOTTED circle cannot be interchanged Single wire connector BLACK BLACK A LIGHT GREY Dual wire connector ...