background image

Service Manual

Philips Consumer Lifestyle

Published by Philips Consumer Lifestyle 

Printed in the Netherlands 

© Copyright reserved 

Subject to modification

 Steam 

Generator

GC7430

11/03

PRODUCT INFORMATION

Features

Iron
-  Steam Glide soleplate
-  Steam rate (Max): 120 g/min
-  Steam trigger with lock
-  Steam hose length: 1.65 m
-  Steam boost: 150 g/min

Stand
- Inox boiler
-  Boiler pressure: 4.5 bar
-  Fixed water tank volume: 1.0 L
-  Cord length: 2.0 m
-  Flex & hose-cord storage hook
- Easy rinse
-  Electronic variable steam control
-  Tank empty light
-  Boiler ready light
-  Anti Calc cartridge in water tank
-  ECO steam setting 

Safety Information

-  This product meets the requirements regarding 

interference suppression on radio and TV.

-  After the product has been repaired, it should function 

properly and has to meet the safety requirements as 
officially laid down as this moment.

TECHNICAL INFORMATION

Voltage   

:  220 - 240 V

Frequency 

:  50 - 60 Hz

Power Iron 

800 

W

  

Boiler 

: 1370 

W

Dimension (F-box) 

:  350 x 350 x 250 mm (L x W x H)

Weight (with packing)  :  6.4 kg

Water advice

If the tap water in your area is very hard, it is advisable to mix 
the tap water with an equal amount of demineralised water.

Easy to rinse

The new design of the rinse cap makes it very easy to rinse 
the boiler regularly.  Simply unscrew the cap and pour out the 
“dirty” water into the sink.
No hassle with coins, extra tubes or anything of this sort.

Fixed water tank

The fi xed water tank that is incorporated into the stand allows 
re-fi lling anytime during ironing.  Since water is not re-fi lled 
directly into the boiler, there is no waiting time for boiler to 
cool down.

Summary of Contents for GC7430

Page 1: ...nd TV After the product has been repaired it should function properly and has to meet the safety requirements as officially laid down as this moment TECHNICAL INFORMATION Voltage 220 240 V Frequency 50 60 Hz Power Iron 800 W Boiler 1370 W Dimension F box 350 x 350 x 250 mm L x W x H Weight with packing 6 4 kg Water advice If the tap water in your area is very hard it is advisable to mix the tap wa...

Page 2: ... rear HOUSING Part 2 DISASSEMBLY ADVICE IRON INLAY 4 LAMP ASSY 7 MICROSWITCH ASSY 9 TRIGGER 12 THERMOSTAT DIAL ASSY 14 HOUSING PRINTED 16 SOLEPLATE COVER 17 THERMOSTAT BUSH 19 RUBBER HOSE BRASS JOINT SOLEPLATE ASSY 23 Remove Screw A Disassemble BACKPLATE 1 Disassemble TRIGGER 12 Tip Disassemble TRIGGER by inserting a sharp object into the gap at the rear of the trigger prying upward Remove Screw C...

Page 3: ...19 23 24 25 26 27 4239 026 38261 4239 021 55931 4239 021 55651 4239 021 46071 4239 021 42390 4239 026 38221 4239 014 54370 4239 021 55641 4239 021 55621 4239 026 38181 4239 015 70150 4239 026 13220 4239 021 41330 4239 015 56120 4239 015 56510 4239 026 38241 4239 021 31780 Backplate Hose cord mounted assy Inlay SOS soft touch Lamp mounted assy Microswitch assy Trigger Trigger spring Thermostat dial...

Page 4: ...GC7430 4 8 EXPLODED VIEW IRON A 7 Cord clamp E1 D1 D3 D2 C B1 B2 E2 E3 2 17 18 1 14 12 13 4 26 9 25 19 16 27 24 23 ...

Page 5: ...isassemble RINSE RUBBER COUPLING 50 Remove Screws K1 K2 K3 K4 Disconnect INLET TUBE PUMP Disconnect DE AIR TUBE Disassemble WATER TANK ASSY 34 Disassemble BRAIDED RUBBER HOSE BOILER Disassemble PUMP ASSY 45 Remove Torx screws L1 L2 L3 Disassemble TOP SPACER Disassemble BOILER ASSY 38 PARTS LIST STAND Note For Pos 45 please replace both components together when either one is faulty The 2 components...

Page 6: ...GC7430 6 8 EXPLODED VIEW STAND 58 F1 K1 H1 H2 K2 K4 K3 F2 G F3 40 56 38 42 34 36 52 50 55 Cord clamp Clamping plate 37 43 L2 L3 L1 J1 J2 45 65 30 33 ...

Page 7: ... Soleplate temperature Check that soleplate temperature is within IEC requirement Measure the temperature of the soleplate after the iron has reached steady state i e connected to the mains for at least 15 minutes The table below shows the temperature requirement Marking Soleplate temperature Deg C Material for example Test point Minimum Maximum Nominal Tolerance 1 dot 70 120 95 25 Acetate elastan...

Page 8: ...GC7430 8 8 REPAIR INSTRUCTIONS Pump Assy Wire connections Connector positions in DOTTED circle cannot be interchanged Single wire connector BLACK BLACK A LIGHT GREY Dual wire connector ...