background image

GC7530

4-8

A

S

N

L

E

B1

B2

D3

E2

D2

D1

E1

E3

C

13

14

17

11

10

6

4

9

1

3

12

15

18

19

5

8

EXPLODED VIEW - IRON

Summary of Contents for GC7530

Page 1: ...ce suppression on radio and TV After the product has been repaired it should function properly and has to meet the safety requirements as officially laid down at this moment TECHNICAL INFORMATION Voltage 220 240V Frequency 50 60 Hz Power Iron 800 W Boiler 1370 W Product dimension 42 9 x 40 x 20 6 cm Weight of iron 1 2 kg Weight of iron base 4 5 kg Water advice If the tap water in your area is very...

Page 2: ...g 2 Wiring at rear HOUSING Part 2 INLAY 17 STEAM LOCK 13 LAMP ASSY 8 MICROSWITCH ASSY 11 TRIGGER 12 THERMOSTAT DIAL ASSY 15 HOUSING PRINTED 10 SOLEPLATE COVER 6 THERMOSTAT BUSH 9 BRAIDED RUBBER HOSE 3 SOLEPLATE ASSY 1 Remove Screw A Disassemble BACKPLATE 18 Release Inlay rear catch Disassemble INLAY 17 Disassemble STEAM LOCK 13 Disassemble MICROSWITCH ASSY 11 Remove Screw C Disassemble TRIGGER 12 ...

Page 3: ...015 59301 4239 010 10281 4239 015 70153 4239 026 48361 Soleplate assy 230V Braided rubber hose Hose clip braided rubber hose Ryton ring Soleplate cover Steamglide Non SOS Purple 8 9 10 11 12 4239 021 36861 4239 026 13222 4239 021 68841 4239 021 31793 4239 026 48371 Lamp mounted assy Thermostat bush Housing printed Microswitch assy Trigger Fuchsia 13 14 15 17 18 4239 026 48561 4239 010 09293 4239 0...

Page 4: ...GC7530 4 8 A S N L E B1 B2 D3 E2 D2 D1 E1 E3 C 13 14 17 11 10 6 4 9 1 3 12 15 18 19 5 8 EXPLODEDVIEW IRON ...

Page 5: ...G 50 Remove Screws K1 K2 K3 K4 Disconnect INLETTUBE PUMP Disconnect DE AIRTUBE Disassemble WATERTANK ASSY 34 Disassemble BRAIDED RUBBER HOSE BOILER Disassemble PUMP ASSY 45 Remove Torx screws L1 L2 L3 Disassemble TOP SPACER Disassemble BOILER ASSY 38 DISASSEMBLY ADVICE STAND PARTS LIST STAND Note For Pos 45 please replace both components together when either one is faulty The 2 components come as ...

Page 6: ...GC7530 6 8 F1 K1 K2 K4 K3 F2 G F3 40 56 38 42 36 52 50 65 L2 L3 L1 30 34 Clamping plate 33 H1 H2 37 J1 J2 45 55 Cord clamp 43 EXPLODEDVIEW STAND ...

Page 7: ...1 Soleplate temperature Check that soleplate temperature is within IEC requirement Measure the temperature of the soleplate after the iron has reached steady state i e connected to the mains for at least 15 minutes The table below shows the temperature requirement Marking Soleplate temperature Deg C Material for example Test point Minimum Maximum Nominal Tolerance 1 dot 70 120 95 25 Acetate elasta...

Page 8: ...GC7530 8 8 Single wire connector BLACK BLACK A LIGHT GREY Dual wire connector Pump Assy Wire connections Connector positions in DOTTED circle cannot be interchanged REPAIR INSTRUCTIONS ...