background image

GC8260

5-9

TRAY RUBBER (MAIN) 30

TRAY 33

STAND TOP  34

FRONT PANEL PRINTED 37

BOILER ASSY  EE  38

ELECTROVALVE 40

POWER BOARD 43

CONTROL BOARD 44

PUMP ASSY  45

INLET TUBE  46

DE-AIR TUBE  47

RINSE RUBBER COUPLING 50

RINSE BUSH 51

SAFETY CAP ASSY 52

REED SWITCH ASSY 53

Remove 

WATER TANK ASSY 70

Remove 

TRAY RUBBER (MAIN) 30 (3x)

Remove 

Screws J1, J2, J3

Disassemble 

TRAY 33

Remove 

Screws K1, K2, K3, K4

Disconnect 

INLET TUBE 46

Disconnect 

DE-AIR TUBE 47

Remove 

SAFETY CAP ASSY 52

Remove 

RINSE BUSH 51

Remove 

RINSE RUBBER COUPLING 50

Disassemble 

STAND TOP 34

Remove 

Screws L1, L2

Disassemble 

FRONT PANEL PRINTED 37

M1

M2

M3

12

11

10

9

 Pos. Connected 

to 

Pos. Connected 

to

    9 

Reed switch 

11 

Thermistor

 10  Power 

board 

12  Hosecord (Black)

Fig 5.  Connections on CONTROL BOARD 44

DISASSEMBLY ADVICE - STAND & DETACHABLE WATER TANK

Remove 

Connections 9, 10, 11, 12  (Fig 5)

Remove 

Screws M1, M2, M3  (Fig 5)

Disassemble  

CONTROL BOARD 44

21

20

15

14

18

13

22

16

17

19

  Pos.  Connected to 

Pos.  Connected to

 13  Pump-Control 

18  Electrovalve-Live

  14  Pump-Live (Brown) 

19  Hosecord (Blue)

 15  Boiler-Heating 

Element 

20  Hosecord (Brown)

 16  Boiler-Fuse 

21  Cordset (Brown)

 17  Electrovalve-Control 

22  Cordset (Blue)

Fig 6.  Connections on POWER BOARD 43

WATER TANK ASSY  70

TANK WASHER  71

TANK COUPLING 73

TANK LEVER 75

PICK UP TUBE 77

FILTER ASSY  78

Remove 

Screws N1

Disassemble 

TANK WASHER 71

Remove 

SCREWS N2, N3

Disassemble 

TANK COUPLING 73

Summary of Contents for GC8260

Page 1: ...ession on radio and TV After the product has been repaired it should function properly and has to meet the safety requirements as officially laid down as this moment TECHNICAL INFORMATION Voltage 220 240 V Frequency 50 60 Hz Power Iron 800 W Boiler 1200 W Dimension F box 350 x 350 x 250 mm L x W x H Weight with packing 6 4 kg Water advice If the tap water in your area is very hard it is advisable ...

Page 2: ...2 DISASSEMBLY ADVICE IRON INLAY 4 STEAM LOCK 6 LAMP ASSY 7 MICROSWITCH ASSY 9 SWITCH HOLDER 10 PIVOT HOLDER 11 TRIGGER 12 THERMOSTAT DIAL ASSY 14 HOUSING PRINTED 16 SOLEPLATE COVER 17 THERMOSTAT BUSH 19 RUBBER HOSE 20 BRASS JOINT 21 SOLEPLATE ASSY 23 Remove Screw A Disassemble BACKPLATE 1 Release Inlay rear catch Disassemble INLAY 4 Disassemble STEAM LOCK 6 Disassemble SWITCH HOLDER 10 Disassemble...

Page 3: ...1 32580 4239 026 01220 4239 021 31790 4239 026 21780 4239 026 21790 4239 026 21800 4239 010 09290 4239 021 32900 4239 014 53790 4239 021 32880 4239 021 32870 4239 015 70150 4239 026 13220 4239 015 56520 4239 010 09350 4239 010 10280 4239 021 31710 4239 015 56120 4239 015 56510 4239 026 22630 4239 021 31780 4239 010 10110 Backplate Swivel Yellow Hose cord assy Inlay SOS Soft Touch Lamp cover Steam ...

Page 4: ...GC8260 4 9 EXPLODEDVIEW IRON 6 5 13 22 4 26 9 10 11 16 17 27 24 19 23 20 21 2 7 8 12 14 15 1 3 18 25 A S N L E B1 B2 D3 Hose clip a Hose clip b E2 D2 C D1 E1 E3 28 22 ...

Page 5: ...L PRINTED 37 M1 M2 M3 12 11 10 9 Pos Connected to Pos Connected to 9 Reed switch 11 Thermistor 10 Power board 12 Hosecord Black Fig 5 Connections on CONTROL BOARD 44 DISASSEMBLY ADVICE STAND DETACHABLE WATERTANK Remove Connections 9 10 11 12 Fig 5 Remove Screws M1 M2 M3 Fig 5 Disassemble CONTROL BOARD 44 21 20 15 14 18 13 22 16 17 19 Pos Connected to Pos Connected to 13 Pump Control 18 Electrovalv...

Page 6: ... Tray rubber Front Tray Safe storage Stand top Yellow Nipple plate Cord storage lever Yellow Front panel printed Boiler assy EE C Wall Electrovalve Braided hose Inox clamp Power board Control board Pump assy Inlet tube De air tube Pos Service code Description 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 4239 015 55980 4239 015 55990 4239 015 56050 4239 026 22430 4239 022 56480 4239 021 31...

Page 7: ...GC8260 7 9 EXPLODEDVIEW STAND 58 35 30 31 32 33 34 36 45 44 62 60 49 61 63 64 41 42 K4 K2 K1 K3 M2 L2 L1 M3 M1 J1 J2 J3 59 37 40 39 3 43 55 49 53 54 48 57 56 20 38 47 46 52 51 50 65 ...

Page 8: ... 70 71 72 73 74 4239 021 32920 4239 026 22130 4239 015 55390 4239 026 22110 4239 015 56060 Water tank assy Yellow Tank washer Sealing ring Tank coupling Tank coupling seal Pos Service code Description 75 76 77 78 4239 026 22530 4239 010 09330 4239 015 56070 4239 021 31860 Tank lever Yellow Spring Pick up tube Filter assy ...

Page 9: ...1 Soleplate temperature Check that soleplate temperature is within IEC requirement Measure the temperature of the soleplate after the iron has reached steady state i e connected to the mains for at least 15 minutes The table below shows the temperature requirement Marking Soleplate temperature Deg C Material for example Test point Minimum Maximum Nominal Tolerance 1 dot 70 120 95 25 Acetate elasta...