background image

 
Philips GreenPower TLED InstantFit

Photon flux
(typical) per module

Power 
consumption

Lifetime 

Ordering code

Ordering code

µmol/s

W

hours

12NC

6NC

Deep red/white (DR/W)

GreenPower TLED DR/W 14.5W MB InstantFit UL/CSA

20

14.5

25,000

9290 008 96406

259 358

Deep red/white/far red (DR/W/FR)

GreenPower TLED DR/W/FR 14.5W MB InstantFit UL/CSA 20

14.5

25,000

9290 008 96506

259 374

Specification and ordering information / Spécifications et information de commande

Philips Lighting  

A division of Philips Canada
281 Hillmount Road
Markham, Ontario, Canada L6C 253
Phone: 800-555-0050

© 2015 Royal Philips N.V. All rights reserved. Philips reserves the right 
to make changes in specifications and/or to discontinue any product 
at any time without notice or obligation and will not be liable for any 
consequences resulting from the use of this publication.

Document ordernr: 3222 635 69454 
03/2015
Data subject to change

For more information about 
Philips Horticulture LED Solutions 
visit: www.philips.com/horti

Write us an e-mail:
horti.info@philips.com

Or tweet us:
@PhilipsHorti 

Philips Lighting  

A division of Philips North America
200 Franklin Square Drive
Somerset, America NJ 08873
Phone: 855-486-2216

Note / Remarque:
1)  Confirm that the ballast in the luminaire (typically located in the ballast channel) is an instant start ballast mentioned in the list above /  

Vérifier que le ballast dans le luminaire est un ballast à allumage instantané (généralement situee dans le canal dus ballast).

2)   Verify the fluorescent tube type is listed on the label of Philips LED T8 InstantFit lamp /  

Vérifier le type de tube fluorescent est indiqué sur l’etiquette de lampe Philips LED T8 InstantFit.

Remove diffuser (if provided) /  

Retirez le diffuseur (si inclu).

Switch-off power to the luminaire / 

 

Coupez l’alimentation du luminaire.

Switch on power to the luminaire /  

Allumez l’interrupteur du luminaire.

 Install the Philips GreenPower TLED InstantFit lamp 
(one for each fluorescent lamp removed) / 

 

Installer la lampe GreenPower TLED InstantFit Philips 
(une pour chaque lampe fluorescente retirée).

Replace diffuser (if removed in step 2) /  

Remplacement le diffuseur en cas de renvoi à  
l’étape 2.

Remove the existing fluorescent lamps from the luminaire /  

Retirez les lampes fluorescente.

1

4

2

5

3

6

Lifetime and maintenance values are given at an ambient temperature of 25 °C, and a photon flux maintenance of 70%. /  

Les valeurs de durée de vie et de maintenance sont indiquées pour une température ambiante de 25 °C et une maintenance de flux de photons de 70%.

The light output and power consumption are 
based on the optimal (reference)driver; Philips 
ICN-1P32-N. The use of a different driver will lead 
to different values in lightoutput and (system) 
power consumption.   

Le rendement lumineux et la consommation sont 
basés sur le driver optimal (de référence) : Philips 
ICN-1P32-N. L’utilisation d’un autre driver 
entraînera des valeurs différentes en rendement 
lumineux et en consommation (du système).

List of compatible ballasts / List de ballasts compatibles

Philips Advance Models: 

GOPA-2P32-SC, GOPA-4P32-SC, GOPA-2P32-LW-SC, GOPA-4P32-LW-SC, IOPA-2P32-N, 

IOPA-4P32-N, IOPA-2P32-LW-N, IOPA-4P32-LW-N, IOP-2P32-N, IOPA-4P32-N, IOPA-2P32-LW-N, IOPA-4P32-
LW-N, ICN-2P32-N, ICN-4P32-N

ULT Models: 

B2321347HP-A, B4321347HP

GE Models: 

GE232MAX347-N, GE432MAX347-N

UltraSave Models: 

UT232347, UT432347