background image

STEP 1: Loosen the shroud screw and remove the shroud.
 
        If the lamp is installed remove it as well. Then loosen
 
        the (2) screws inside the housing.

STEP 2: Rotate the heat shield until it is on top of the lamp
 
        assembly. This depends on how you will be mounting the
 
        fixture. Once it is in the proper location tighten down
 
        the (2) screws, replace the lamp and shroud and tighten
 
        the shroud screw.

HEAT SHIELD INSTRUCTIONS

Depending on how the fixture is mounted you may need to adjust the placement of the heat shield.
 
The Heat Shield should always be on top of the lamp assembly. Failure to adjust the heat shield
 
properly may cause the outside of the fixture to become excessively hot and be a safety hazard for
 
the customer to touch.

INSTALLATION INSTRUCTIONS

1.  Thread fixture onto ground mounted stake or box (not supplied).

6.  Wire fixture following the directions for the Low Voltage Connector on the back of this page or hardwire

to low voltage cable.

2.  Loosen shroud screw (see illustration above) and remove shroud.
3.  Insert MR16 lamp (50 W MAX.) (not supplied) into socket.
4.  Replace shroud, rotate to desired position, and tighten screw.
5.  Loosen screw in arm, aim fixture to desired position, and tighten screw.

    Loosen
 
(DO NOT REMOVE)

Shroud

Lamp

Shroud screw

Heat shield

page 2 of 3

32001444, revision B

Reviews: