English
Introduction
Congratulations on your purchase and welcome to
Philips! To fully benefit from the support that
Philips offers, register your product at
www.philips.com/welcome
.
General description (Fig. 1)
General description (Fig. 1)
1 Trimming comb 1-23 mm
2 Cutting unit
3 Length setting adjustment slide
4 On/off slide
5 Small plug
6 Supply unit
7 Brush
Important safety information
Read this important information carefully before
you use the appliance and its accessories and save
it for future reference.
Danger
-
Keep the supply unit dry (Fig. 2).
Warning
-
Only use the detachable supply unit (HQ8505)
provided with the appliance.
-
The supply unit contains a transformer. Do not
cut off the supply unit to replace it with another
plug, as this causes a hazardous situation.
-
This appliance can be used by children aged
from 8 years and above and persons with
reduced physical, sensory or mental capabilities
or lack of experience and knowledge if they
have been given supervision or instruction
concerning use of the appliance in a safe way
and understand the hazards involved. Children
shall not play with the appliance. Cleaning and
user maintenance shall not be made by
children without supervision.
-
Always check the appliance before you use it.
Do not use the appliance if it is damaged, as
this may cause injury. Always replace a
damaged part with one of the original type.
Caution
-
This appliance is not washable. Never immerse
the appliance in water and do not rinse it under
the tap (Fig. 2).
-
Only use this appliance for its intended purpose
as shown in the user manual.
-
For hygienic reasons, the appliance should only
be used by one person.
-
Never use compressed air, scouring pads,
abrasive cleaning agents or aggressive liquids
such as petrol or acetone to clean the
appliance.
-
Do not use the supply unit in or near wall
sockets that contain an electric air freshener to
prevent irreparable damage to the supply unit.
Electromagnetic fields (EMF)
This Philips appliance complies with all applicable
standards and regulations regarding exposure to
electromagnetic fields.
General
-
The supply unit is suitable for mains voltages
ranging from 100 to 240 volts.
-
The supply unit transforms 100-240 volts to a
safe low voltage of less than 24 volts.
Using the appliance
The hair length settings are indicated in
millimeters, the comb cuts the hair to a length of
1 mm to 23 mm. The settings correspond to the
remaining hair length after trimming.
Warning: Be careful when you trim for the first
time. Do not move the trimmer too fast. Make
smooth and gentle movements.
Tip: Start trimming at a high length setting and
reduce the length setting gradually until you have
reached the desired hair length.
Switching the appliance on and off
Note: You can only use the appliance when it is
connected to the wall socket.
1 Insert the small plug into the appliance and put
the supply unit in the wall socket (Fig. 4).
2 Push the on/off slide upwards to switch on the
appliance (Fig. 5).
3 Push the on/off slide downwards to switch off
the appliance (Fig. 6).
Trimming with the trimming comb
1 Attach the trimming comb to the appliance (Fig. 7).
2 slide the length setting adjustment slide to the
desired length setting (Fig. 8).
Note: When you trim for the first time, start at
the highest length setting to familiarize yourself
with the appliance.
3 Switch on the appliance (Fig. 5).
4 Move the appliance slowly and with light
pressure against the direction of hair growth
(Fig. 9).
Note: Make sure that the flat part of the comb
always stays in contact with the skin to obtain
an even result (Fig. 10).
Trimming without comb
Use the trimmer without the trimming comb to trim
hair close to the skin (0.5 mm) or to contour the
neckline and sideburns.
Caution: Be careful when you trim without a comb
because the cutting unit removes every hair it
touches.
Pull the comb off the appliance (Fig. 11).
Switch on the appliance (Fig. 5).
Touch the hair lightly with the trimmer. Make
well-controlled movements (Fig. 12).
Cleaning
Warning: Never use scouring pads, abrasive
cleaning agents or aggressive liquids such as
petrol or acetone to clean the appliance.
Warning: Never immerse the appliance in water
and do not rinse it under the tap.
Note: Only the cutting element and the comb can
be cleaned with water.
1 Make sure that the appliance is switched off and
disconnected from the wall socket.
2 Wipe the housing of the appliance with a dry
cloth.
3 Remove the comb. Clean it with the cleaning
brush and rinse it with water (Fig. 13).
4 Press the release button. The cutting unit
comes off the appliance (Fig. 14).
5 Clean the cutting unit with the cleaning brush or
rinse it under the tap (Fig. 15).
6 Clean the inside of the appliance with the
cleaning brush (Fig. 16).
7 Shake off excess water.
8 Insert the lug of the cutting unit into the guiding
slot and push the cutting unit back onto the
appliance (Fig. 17).
Replacement
Only replace a worn or damaged cutting unit with
an original Philips cutting unit, available from
authorized Philips service centers.
1 Press the release button. The cutting unit
comes off the appliance (Fig. 14).
2 Insert the lug of the new cutting unit into the
guiding slot and push the cutting unit onto the
appliance (Fig. 17).
Ordering accessories
To buy accessories or spare parts, visit
www.philips.com/parts-and-accessories
or go to
your Philips dealer. You can also contact the Philips
Consumer Care Center in your country (see
the international warranty leaflet for contact
details).
Troubleshooting
This chapter summarizes the most common
problems you could encounter with the appliance.
If you are unable to solve the problem with the
information below, visit
www.philips.com/support
for a list of frequently asked questions or contact
the Consumer Care Center in your country.
Problem
Possible
cause
Solution
The
appliance
produces
an uneven
cutting
result.
The comb
does not touch
the skin when
you move
the appliance
through the
hair.
Make sure the comb
is always fully in
contact with the skin
when you move the
appliance through
the hair.
You only move
the appliance in
one direction.
Because not all
hairs grow in the
same direction,
move the appliance
in different
directions (upwards,
downwards and
across).
The setting of
the comb has
changed during
trimming.
Check the setting
of the comb. If you
push the appliance
too hard onto the
scalp, you may
accidentally change
the setting of the
comb.
The comb is
not assembled
correctly.
Detach the comb
and reattach it.
The cutting
performance
decreases
when the
cutting unit and
the comb are
dirty.
Clean the cutting
unit and the comb
(see 'Cleaning').
Problem
Possible
cause
Solution
The
appliance
does not
work when
I switch it
on.
The appliance
is not
connected to
the the wall
socket.
Insert the small plug
into the appliance
and put the supply
unit in the wall
socket (Fig. 4).
Warranty and support
If you need information or support, please visit
www.philips.com/support
or read the
international warranty leaflet.
Warranty restrictions
Cutting units are not covered by the terms of the
international warranty because they are subject to
wear.
Recycling
-
Do not throw away the product with the normal
household waste at the end of its life, but hand it
in at an official collection point for recycling.
By doing this, you help to preserve the
environment.
-
Follow your country's rules for the separate
collection of electrical and electronic products.
Correct disposal helps prevent negative
consequences for the environment and human
health.
HC3505/15
ENGLISH
1
2
2
1
17
16
15
14
2
3
4
5
6
7
8
9
10
11
12
13
1
2
3
7
6
4
5
1-23mm
1