background image

HD7817/60 /61 /62 /63 /65 /66 /67 /68 /69

5-7

Parts list

Pos

Service code

Description

Remark

1

4222 259 62701

Brew chamber assy

Black

2

4222 259 62781

Pad holder assy 1-cup

Black

3

4222 259 62791

Pad holder assy 2-cup

Black

4

4222 247 74381

Foam chamber cover

Black

5

4222 247 39540

Foam chamber

Black

6

4222 247 66481

Drip tray cover

Black

7

4222 247 72531

Drip tray

8

4222 247 74351

Front cover

Black

9

4222 247 74361

Housing

Black

10

4222 259 62691

Brew chamber lid printed

Black

11

4222 247 74091

Lever

Black

12

4222 247 72881

Pushrod

13

4222 240 06811

Slider spring

14

4222 247 35835

Slider

15

4222 247 07461

Brew chamber seal

16

4222 259 06890

Distributor assy

17

4222 259 59541

3-way valve

18

4222 259 52091

Boiler assy

V7.0 - 230 V

19

4222 247 61940

TCO cap

20

4222 247 43690

Boiler pin cap

21

4222 247 72551

Suspension bracket

22

4222 247 06511

Pressure hose

23

4222 259 61702

PCB assy 

1

24

4222 259 62221

Button frame printed

Black

26

4222 259 63421

On/off  button printed

27

4222 247 72932

Base plate

Black

28

4222 247 05130

O-ring

(NTC)

29

4222 259 39372

NTC assy

30

4222 247 39963

Sensor housing

31

4222 259 60213

Water container

Soft grey

32

4222 247 40982

Valve outlet

Black

33

4222 259 60151

Back cover assy

Black

34

4222 259 37244

Pump

230 V / 50 Hz

35

4222 247 05191

Pump damper

36

4213 247 05256

Foot

100

4222 244 50680

Ty-wrap

1)

  When you replace the PCB the coff ee volume has to be re-set to your country specifi c 

setting.  Please carry out the Volume Adjustment Procedure to align the volume to your 

local specifi cation  (see table).

Summary of Contents for HD7817/60

Page 1: ...ion This product meets the requirements regarding interference suppression on radio and TV After the product has been repaired it should function properly and has to meet the safety standards as officially laid down at this moment Technical information Voltage 230 V Frequency 50 Hz Power consumption 1450 W Standby power consumption 0 5 W Stand by time 30 min Functions Brew stop Contents reservoir ...

Page 2: ...hamber becomes visible Put the screwdriver in to the 4 rectangular holes snap locks at the back and gently pull the screwdriver such away that the lips of the snap locks are bent outwards If all clicks positions are loose it is possible to remove the back cover Reassemble follow steps backwards picture 1 picture 2 Removing Brew chamber head handle as follows Disassemble back cover Place the applia...

Page 3: ...L Max water cc mL France version 104 120 General Europe version 125 141 7 Unplug the appliance from the mains 8 Press the 1 and 2 cup button simultaneously and plug the mains on 9 When above step succeeded the led will turn on continuously 10 Depending if the volume has to de or increase you have to push the one or two cup button Every time you push the 1 or 2 cup button the LED will turn off for ...

Page 4: ...inging the Senseo back into production status has the benefit the flush routine will be activated automatically when installed by the consumer see topic Automatic filling procedure To SET the Boiler_empty_flag can be done by Keep the 1 cup button pressed while plugging in the power cord of the appliance The main switch LED will blink very rapidly for approximately 1 second To check if the Boiler_e...

Page 5: ... 259 59541 3 way valve 18 4222 259 52091 Boiler assy V7 0 230 V 19 4222 247 61940 TCO cap 20 4222 247 43690 Boiler pin cap 21 4222 247 72551 Suspension bracket 22 4222 247 06511 Pressure hose 23 4222 259 61702 PCB assy 1 24 4222 259 62221 Button frame printed Black 26 4222 259 63421 On off button printed 27 4222 247 72932 Base plate Black 28 4222 247 05130 O ring NTC 29 4222 259 39372 NTC assy 30 ...

Page 6: ...HD7817 60 61 62 63 65 66 67 68 69 6 7 A 15 12 10 14 13 11 16 6 2 1 4 3 7 8 5 9 Exploded view ...

Page 7: ...HD7817 60 61 62 63 65 66 67 68 69 7 7 36 35 34 31 32 17 18 22 24 23 19 20 30 21 26 27 29 28 33 A Exploded view ...

Reviews: