HD7825/06/B /07/B
2-8
Before you start dismantling!
For your safety be sure the plug is disconnected
from the mains!
The product is designed for easy access to the internal
components.
Make sure that all accessories like tank, podholder, drip
tray, spout and collector have been removed.
To remove the back cover, follow below steps:
•
Remove the two Torx screws (T15)
A
(see exploded
view).
•
Remove the valve outlet.
•
Start at the upper side of the back cover, using a flat
head screwdriver to unhook the top of the back cover
and gently pull the back cover from the appliance so
that a little chink between back cover and brew chamber
becomes visible.
•
Again use the screwdriver to unhook the two “snap locks”
at each side of the back cover, and gently move the
screwdriver in the direction of the opposite side of the
appliance, in such a way that the lips of the snap locks
are bent outwards and unhook.
•
If all snap locks are unhooked, it is possible to remove
the back cover. Gently pull the back cover upwards
to release the bottom part of the back cover from
the housing. Please note that the back cover is still
connected to the pump.
•
For reassembly follow these steps backwards.
To remove the brew chamber lid cover, follow below
steps:
•
Place a large screwdriver on
the positions (see picture 1)
and lift the cover over the
snap locks on both positions,
use appropriate force.
•
The cover lid can now be
lifted up, but stays attached
to the brew head by the push
rod, to remove the complete
cover including lever and
push rod squeeze both legs
of the push rod strongly
together (see picture 2), so
that the two pins will unhook
out of the hinge position on
the brew chamber.
•
To remove lever from lid cover, take a screwdriver and
bend carefully the two lips/ribs in the lid cover outwards
and push the lever with force out of the hinge.
•
To reassemble, follow steps backwards, without using a
screwdriver.
picture 1
picture 2
To remove the brew chamber head assy, follow below
steps:
•
Remove the back cover.
•
Place the appliance in front of you in such a way that you
are facing the rear side of the appliance.
•
First remove the boiler from the snap lock position of the
brew chamber.
•
To remove the brew chamber,
use your both thumbs
(see picture 3) and push
strongly with a little distortion
(rotation) until the brew
chamber comes loose
(upwards).
•
Reassemble follow above steps backwards.
To reach the components placed inside the base (for
example exchange the NTC temperature sensor) follow
below steps:
•
First remove back cover, three-way valve and boiler.
•
The brew chamber can be removed by unhooking the
two snap locks behind the boiler, pull the brew chamber
upwards to remove it from the housing.
•
Remove both Torx T15 screws
B
(see exploded view).
•
Unhook the two snap locks on the back side of the base
with a screwdriver (see base), the housing can now be
removed.
•
To remove the rest of the housing unlock the last 4 snap
locks on the base and gently pull of the front cover.
•
To reassemble follow above steps backwards.
OPTIONAL (accessories)
•
No specific issues
picture 3
Disassembly- and reassembly advice