Exploded view

Summary of Contents for HD7825/06/B

Page 1: ...ents regarding interference suppression on radio and TV After the product has been repaired it should function properly and has to meet the safety standards as officially laid down at this moment Technical information Voltage 220 240 V Frequency 50 60 Hz Power consumption 1450 W Standby power consumption 0 5 W Contents water reservoir 900 cc Colour setting White Red Functions Direct start Brew sto...

Page 2: ... by the push rod to remove the complete cover including lever and push rod squeeze both legs of the push rod strongly together see picture 2 so that the two pins will unhook out of the hinge position on the brew chamber To remove lever from lid cover take a screwdriver and bend carefully the two lips ribs in the lid cover outwards and push the lever with force out of the hinge To reassemble follow...

Page 3: ...he volume output by means of pushing the one cup and two cup user controls How to adjust the volume output 1 Make sure the boiler is filled properly otherwise perform fill procedure see DFU for instructions 2 Switch appliance on and wait until the unit is ready to brew 3 Make sure a pod holder is placed but without a Coffee POD Only adjusting with plain water 4 Place a cup on the drip tray cover a...

Page 4: ... Boiler_ empty_flag to factory default Restoring the Boiler_empty_flag to factory default Under some circumstances it might be necessary that the boiler of the Senseo is emptied This for instance during wintertime were the possibility exists that the boiler becomes frozen during transport For those occasions it is useful to restore the Boiler_ empty_flag to production default Bringing the Senseo b...

Page 5: ...assy White Red 13 4222 247 06814 Brew chamber seal 14 4222 240 05991 Ejector pin 15 4222 247 41922 Distribution disk 16 4222 259 52721 PCB assy LE Red LED 17 4213 247 05256 Foot 18 4222 259 59581 3 way valve 19 4222 259 52091 Boiler assy V7 0 230 V 20 4222 247 06591 Pressure hose 21 4222 247 05134 O ring NTC 22 4222 259 47301 NTC assy 23 4222 259 37244 Pump 230 V 50 Hz 24 4222 247 71141 Valve outl...

Page 6: ...HD7825 06 B 07 B 6 8 1 2 8 4 6 3 7 5 Exploded view ...

Page 7: ...HD7825 06 B 07 B 7 8 a 10 15 13 14 9 11 12 Exploded view ...

Page 8: ...HD7825 06 B 07 B 8 8 19 20 21 22 23 24 26 25 16 18 16 17 28 27 A 2x B 2x a b b y y z z 29 33 33 34 Exploded view ...