5
3
REPLACE
HANDLE 6 + 7
remove
SCREW B
remove
SCREW C
remove
SCREW D
remove
SCREW E
REPLACE SWIVEL 8
REPLACE HOSE 9
REPLACE
PILOT LAMIP 10
disassemble
HANDLE
PARTS 6+7
remove
SCREW F 2 x
remove
CONNECTING
WIRES
remove
CLAMP( S )
REPLACE
CORK GRIP 11
disassemble
HANDLE
PARTS 6+7
remove
SCREW G
remove
SCREW H
REPLACE COVER 16
REPLACE
SOLE PLATE 18
REPLACE
THERMOSTAT 19
REPLACE
INSULATING PLATE 20
remove
DIAL 1
remove
RING 2
remove
HANDLE
PARTS 6+7
remove
HOSE
remove
SLEEVE
remove
CORK GRIP
remove
SCREW I
remove
BRACKET 21
turn
conductor B through
180 degrees
remove
PLATE 17
THERMOSTAT 19 ONLY
cut
CONDUCTOR A
at location P
remove
SCREW J
ASSEMBLY
REQUIREMENTS
THERMOSTAT 19
Instead of metal conductor A,
the new thermostat has a wire
with AMP clamp.
After fixing screw J, connect the
AMP clamp to tag Q.
After assembling cover 16
ALWAYS turn conductor B
through 180 degrees.
ADVICE IRON
ADJUSTMENT AND CONTROLS
Thermostat 19
Thermostat ( 19 ) supplied as a spare part or fitted to the sole plate
( 18 ) has already been adjusted by the supplier and secured by glue.
To avoid disfunction of the iron, NEVER readjust the
thermostat.
PCS 88 247