Parts list stand
pos
description
service code
HI980
HI984
30
30.1
31
32
cap + safety valve
Sealing
tray
cover stand
4822 462 10895
4822 466 11489
4822 418 10243
4822 442 00789
x
x
x
x
x
x
x
x
33
34
35
36
rubber distance piece
rubber buffer
housing stand
boiler complete HI980
4822 325 71999
4822 466 11398
4822 441 11914
4822 218 11596
x
x
x
x
x
x
x
-
37
38
39
boiler complete HI984
steam hose ( black ) HI984 “Y - Y”
steam hose ( red ) HI980
“Z - Y”
cordset Euro, colour black
4822 218 11597
4822 530 10378
4822 530 10379
4822 321 11291
-
-
x
x
x
x
-
x
40
41
cordset Italy, colour black
cordset UK, colour black
switch(es) boiler
manometer
4822 321 11292
4822 321 11293
4822 276 13848
4822 349 11023
x
x
x
-
x
x
x
x
42
43
44
45
steam control valve
sealing of filling opening
clamping bracket hose
rubber foot
4822 360 10278
4822 532 12773
4822 401 11686
4822 462 10896
-
x
x
x
x
x
x
x
46
pilot light
4822 134 10077
x
x
PARTS LIST + DISASSEMBLY ADVICE STAND
ADJUSTMENT AND CONTROLS
Pressostat 101
The pressostat ( 101 ) fixed to the boiler has already been adjusted.
The adjustment has been secured by glue.
To avoid dangerous situations, NEVER try to adjust or
readjust the pressostat.
IMPORTANT
− When the thermal fuse ( 104 ) is open, the boiler has been
subjected to too high temperatures.
In that case, the complete boiler must be replaced for
safety reasons.
− To avoid leakage of the sealings and damage to the components in
and on the boiler :
Never clean the boiler with vinegar, a descaling agent or
other chemicals
.
−
When the safety valve, located in the cap ( 30 ), has been
activated, the COMPLETE PRODUCT has to be replaced.
−
THE COMPLETE BOILER HAS TO BE REPLACED WHEN:
*
the pressostat ( 101 ) doesn’t function properly.
*
the electrovalve ( 103 ) fails or the sieve is soiled with
scale.
*
the thermal fuse ( 104 ), boiler thermostat ( 105 ) or hand
- resettable thermostat ( 106 ) are open, because the
boiler has been subjected to too high temperatures.
−
When replacing the sealing of filling opening of the boiler
( 43 ), always add silicone pasta suitable for general
purposes.
−
When the water hardness is higher than 17° DH / 21°
Clarke, it’s advised to use distilled water.
−
Due to standardisation, only tube 37 “Y - Y” has been
incorporated into the service manual.
Components with numbers from 100 and higher cannot be ordered separarely
BOILER COMPLETE
The boiler complete
consists of:
boiler body
pressostat 101
sieve + electro valve 103
boiler thermostat 105
hand-resettable thermostat 106
fuse 104
sealing of the filling opening 43
pilot light( s ) boiler 46
cap + safety valve 30
electrical wiring
DISASSEMBLY ADVICE
STAND
to open the
STAND
remove
CAP 30
remove
INLAY 31
remove
SCREW K 6x
remove
COVER 32