background image

DU-PH-0062-60 Rev A 7/16/07 GCX Corp Page 1 of 7 

Installation Guide

 

 

Philips MP2/MP5 Roll Stand 

 
 

The purpose of this guide is to: 
1.  Describe assembly of Roll Stand (pages 2 – 3). 
2.  Describe attachment of Fixed Tilt Mounts (page 4). 
3.  Describe mounting MP5 on Roll Stand (page 5). 
4.  Describe mounting MP2 on Roll Stand (page 6). 
5.  Describe cable management – MP2 only (page 7). 
 
 

 
 

 

WARNING:

 USE OF THIS ROLL STAND FOR INSTRUMENTS OTHER THAN THOSE DESCRIBED IN 

THIS DOCUMENT MAY RESULT IN INJURY DUE TO TIPPING OF THE ROLL STAND. THE CUSTOMER 

SHOULD VERIFY THE STABILITY OF ANY DEVIATION FROM THE CONFIGURATIONS SHOWN. 

 

 

Parts Reference 

The following parts and hardware are included with this installation kit (hardware not shown): 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
Tools Required:  

Phillips screwdriver (not provided), 1/2'' [13mm] wrench (not provided). 

Item # 

Description 

Qty 

1 Post, 

40'' 

2 Base, 

21'' 

5/16-18 x 1'' Hex Head Cap Screw (HHCS) 

5/16 Flat Washer 

5/16 Split Lock Washer 

6 Utility 

Basket 

7 Basket 

Clip 

#8-32 x 7/8'' Pan Head Machine Screw (PHMS) 

#8-32 Hex Nut 

10 Handle 

11 

#10-32 x 9/16'' PHMS 

12 

Fixed Tilt Mount, MP5 

 

13 

Fixed Tilt Mount, MP2 

14 

M4 x 14mm PHMS 

15 

#10-32 x 3/4''  Flat Head Machine Screw (FHMS) 

16 

Power Supply Mount 

17 

M4 x 12mm PHMS 

18 

M6 x 10mm FHMS 

19 

M6 x 8mm PHMS 

20 

Cable Clip (not shown – see page 7) 

21 

Screw Cover, Adhesive-backed Lexan 

10

12 

6

13

16

Summary of Contents for IntelliVue MP2

Page 1: ...HE CONFIGURATIONS SHOWN Parts Reference The following parts and hardware are included with this installation kit hardware not shown Tools Required Phillips screwdriver not provided 1 2 13mm wrench not provided Item Description Qty 1 Post 40 1 2 Base 21 1 3 5 16 18 x 1 Hex Head Cap Screw HHCS 1 4 5 16 Flat Washer 1 5 5 16 Split Lock Washer 1 6 Utility Basket 1 7 Basket Clip 2 8 8 32 x 7 8 Pan Head ...

Page 2: ...enter of Base and lay assembly on its side for access to bottom of base not shown 2 Using a 1 2 13mm wrench fasten Post to Base with one 1 5 16 18 x 1 HHCS with 5 16 split lock washer and 5 16 flat washer as shown below Return Roll Stand to upright position 5 16 Flat Washer 5 16 Lock Washer 5 16 18 x 1 HHCS ...

Page 3: ...nd of Roll Stand Post below right and move Basket to mounting position Do not tighten screws at this time Basket may require re alignment after the Fixed Tilt Mount is attached 3 Position the Handle below the top of the Roll Stand Post opposite the Basket Fasten Handle to Post with two 2 10 32 x 9 16 PHMS as shown but do not tighten at this time Handle may require re alignment after the Fixed Tilt...

Page 4: ...nt must be oriented toward the intended front of the roll stand as shown below 2 Remove backing from Lexan Screw Cover and place on top of screw heads as shown below Procedure is same for MP2 Mount shown or MP5 Mount 3 Not shown Align Basket and Handle with the Fixed Tilt Mount orientation and tighten mounting screws as required to secure Basket and Handle on the Post 10 32 x 3 4 FHMS 3 MP5 Fixed ...

Page 5: ...ollow on this page Mounting MP5 on Philips Table Top Mount Requires Philips supplied Table Top Mount 1 Fasten the Philips supplied table top mount to the Mounting Adapter with three 3 M6 x 10mm FHMS as shown below left Mount the monitor in accordance with Philips mounting instructions Mounting MP5 with Non Table Top Mounting Adapter 1 Using a Phillips screwdriver fasten monitor to Fixed Tilt Mount...

Page 6: ...MS as shown below Mount monitor on docking station according to manufacturer s instructions Mounting the Power Supply 1 Fasten Clamping Block to power supply with two 2 M4 x 12 mm PHMS as shown below 2 Fasten power supply to Post with rear Clamping Block and two 2 10 32 x 9 16 PHMS as shown below M4 x 14 mm PHMS 2 M4 x 12 mm PHMS 2 Clamping Block Clamping Block 10 32 x 9 16 PHMS 2 ...

Page 7: ...ducts 1 The mounting assembly may be cleaned with most mild non abrasive solutions commonly used in the hospital environment e g diluted bleach ammonia or alcohol solutions 2 The surface finish will be permanently damaged by strong chemicals and solvents such as acetone and trichloroethylene 3 Do not use steel wool or other abrasive material to clean the mounting assembly 4 Damage caused by the us...

Reviews: