background image

DU-PH-0062-60 Rev A 7/16/07 GCX Corp Page 2 of 7 

Assembling the Roll Stand 

1.  Insert bottom end of Post in center of Base and lay assembly on its side for access to bottom of base (not shown).  

 

2.  Using a 1/2'' [13mm] wrench, fasten Post to Base with one (1) 5/16-18 x 1'' HHCS, with 5/16 split lock washer, and 

5/16'' flat washer as shown below. Return Roll Stand to upright position. 

 

 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5/16 Flat Washer 

5/16 Lock Washer 

5/16-18 x 1'' HHCS 

Summary of Contents for IntelliVue MP2

Page 1: ...HE CONFIGURATIONS SHOWN Parts Reference The following parts and hardware are included with this installation kit hardware not shown Tools Required Phillips screwdriver not provided 1 2 13mm wrench not provided Item Description Qty 1 Post 40 1 2 Base 21 1 3 5 16 18 x 1 Hex Head Cap Screw HHCS 1 4 5 16 Flat Washer 1 5 5 16 Split Lock Washer 1 6 Utility Basket 1 7 Basket Clip 2 8 8 32 x 7 8 Pan Head ...

Page 2: ...enter of Base and lay assembly on its side for access to bottom of base not shown 2 Using a 1 2 13mm wrench fasten Post to Base with one 1 5 16 18 x 1 HHCS with 5 16 split lock washer and 5 16 flat washer as shown below Return Roll Stand to upright position 5 16 Flat Washer 5 16 Lock Washer 5 16 18 x 1 HHCS ...

Page 3: ...nd of Roll Stand Post below right and move Basket to mounting position Do not tighten screws at this time Basket may require re alignment after the Fixed Tilt Mount is attached 3 Position the Handle below the top of the Roll Stand Post opposite the Basket Fasten Handle to Post with two 2 10 32 x 9 16 PHMS as shown but do not tighten at this time Handle may require re alignment after the Fixed Tilt...

Page 4: ...nt must be oriented toward the intended front of the roll stand as shown below 2 Remove backing from Lexan Screw Cover and place on top of screw heads as shown below Procedure is same for MP2 Mount shown or MP5 Mount 3 Not shown Align Basket and Handle with the Fixed Tilt Mount orientation and tighten mounting screws as required to secure Basket and Handle on the Post 10 32 x 3 4 FHMS 3 MP5 Fixed ...

Page 5: ...ollow on this page Mounting MP5 on Philips Table Top Mount Requires Philips supplied Table Top Mount 1 Fasten the Philips supplied table top mount to the Mounting Adapter with three 3 M6 x 10mm FHMS as shown below left Mount the monitor in accordance with Philips mounting instructions Mounting MP5 with Non Table Top Mounting Adapter 1 Using a Phillips screwdriver fasten monitor to Fixed Tilt Mount...

Page 6: ...MS as shown below Mount monitor on docking station according to manufacturer s instructions Mounting the Power Supply 1 Fasten Clamping Block to power supply with two 2 M4 x 12 mm PHMS as shown below 2 Fasten power supply to Post with rear Clamping Block and two 2 10 32 x 9 16 PHMS as shown below M4 x 14 mm PHMS 2 M4 x 12 mm PHMS 2 Clamping Block Clamping Block 10 32 x 9 16 PHMS 2 ...

Page 7: ...ducts 1 The mounting assembly may be cleaned with most mild non abrasive solutions commonly used in the hospital environment e g diluted bleach ammonia or alcohol solutions 2 The surface finish will be permanently damaged by strong chemicals and solvents such as acetone and trichloroethylene 3 Do not use steel wool or other abrasive material to clean the mounting assembly 4 Damage caused by the us...

Reviews: