Need Help? Call us at 1.800.54.AVENT or visit www.aventamerica.com
Manual Pumping with ISIS
™
ISIS Manual Pump Parts Guide
15
Cleaning the ISIS Manual Pump
15
Assembling the ISIS Manual Pump
16
Using the ISIS Manual Pump
17
What’s Inside:
Electric Pumping
(Single and Double)
ISIS iQ DUO Pump Parts Guide
1-2
Warnings and Cautions
3
Disassembling ISIS iQ DUO
5
Cleaning and Sanitizing ISIS iQ DUO
6
Preparing to Pump
7-8
Assembling Pump Bodies
of ISIS iQ DUO
9-10
Connecting the Electronics
of ISIS iQ DUO
11-12
Pumping with ISIS iQ DUO
13-14
Keeping Parts Clean and
Compact for Travel
18
Storing Your Expressed Breast Milk 19-20
Troubleshooting Guide
21
Technical Specifications
22
4
Please take a few minutes to read
through this entire instruction leaflet
before using your ISIS iQ DUO
™
for the
first time.
PLEASE SAVE THESE INSTRUCTIONS.
Congratulations!
Soon you will discover what makes this ISIS iQ Breast Pump so uniquely yours. ISIS iQ is designed with
an electronic memory that learns and continues your gentle pumping rhythm. It gives you complete
control over your comfort, which means that pumping with ISIS iQ always feels natural and exactly
right for you.
Intelligent and intuitive...
It’s your iQ.
Let-down Massage Cushion
™
has petals that
flex in and out to gently massage the area
around your breast. This is intended to help
stimulate a fast, natural milk flow.
One-Touch Memory Control
is right at your
fingertips. You can stop, start or adjust the
speed and suction level without removing
your hand from the pump.
Electronic Memory
learns from you. Just
begin a comfortable pumping rhythm, press
a button and ISIS iQ automates it.
Pump, Store, Feed Convenience
from
the AVENT Natural Feeding System. AVENT
products work together, so you never have
to transfer milk between containers.
Ultra Comfortable, Quiet and Effective
making it easier for you to continue giving
your baby the benefits of breast milk.
When using electrical products, especially when children are present,
basic safety precautions should always be followed.
READ ALL INSTRUCTIONS BEFORE USING THIS PRODUCT.
WARNING – To reduce the risk of fire, electrocution, or other personal injury:
• ISIS iQ DUO
™
is intended for repeated use by a single user only.
• Always unplug the breast pump motor from the electrical outlet immediately after use.
• Do not use while bathing.
• Do not place or store the product where it can be pulled or fall into water.
• Do not place or drop the pump motor, control handle, electric adaptor or wall plug cord into water or other liquid.
• Do not reach for a product that has fallen into water. Unplug from electrical outlet immediately.
• Close supervision is necessary when this product is used near children or persons with disabilities.
• Do not allow children or pets to play with the pump motor, tubing, power supply or accessories as these
parts may pose a choking or strangulation danger.
• There are no serviceable parts inside the ISIS iQ DUO. Do not attempt to open, service or repair the
ISIS iQ DUO yourself.
• Before each use inspect the product, including mains cord, for signs of damage. Never operate this
product if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged,
or has been submerged in water.
• Only use attachments recommended by AVENT.
• Do not use outdoors with the AC adaptor, where aerosol spray products are being used, or where oxygen
is being administered.
• Equipment not suitable for use in the presence of flammable anesthetic mixture with air, or with oxygen
or nitrous oxide.
• Only use the electric adaptor supplied with the product.
• Ensure the unit is not exposed to extreme heat or placed in direct sunlight.
• This product is a personal care item and should not be shared between mothers.
• Do not attempt to remove the pump body from your breast while under vacuum. Turn the unit off and
break the seal between your breast and the pump funnel with your finger, then remove the pump from
your breast.
• Never use while pregnant, as pumping can induce labor.
• Never use when sleepy or drowsy.
CAUTION – To reduce the risks of injury, device malfunction or failure:
• Do not leave product unattended when plugged into an electrical outlet.
• Never drop or insert any object into any opening or tubing.
• Do not shorten the tubing.
• Make sure the voltage of the electrical adaptor is compatible with the power source.
• First plug the adaptor into the breast pump motor. Then, attach the wall plug cord into the adaptor.
Lastly, insert plug into the wall socket.
• Although compliant with applicable EMC directives, this equipment may still be susceptible to
excessive emissions and/or may interfere with other more sensitive material.
• Wash and sanitize the appropriate pump components before each use.
• Do not continue pumping for more than five minutes at a time if no result is achieved.
• Do not use antibacterial cleaners or detergents when cleaning breast pump parts.
• Never put the control handle or breast pump motor in water or sterilizer, as you can cause permanent
damage to the pump.
• If the pressure generated is uncomfortable or causing pain, turn the unit off, break the seal between
the breast and the pump body with your finger and remove the pump from your breast.
3
Warnings and Cautions