Philips Energy Advantage PL-L 25W Lamps
1
D
D
A
B
C
Philips Energy Advantage PL-L 25W Lamps
Ordering, Electrical and Technical Data
Color
Rated Average Life (Hrs.)
1
Approx.
Product
Ordering
Nom
Pack.
Temp.
MOL
3-hr
12-hr
Initial
Design
Lumen
Number
Code
Watts
Base
Qty.
(Kelvin)
(In.)
Start
2
Start
3
Lumens
4
Lumens
5
CRI
Maint.
209130
PL-L 40W/830/XEW/4P/IS 25W
25
2G11
25
3000K
22½
20,000
24,000
2600
2470
82
95%
209148
PL-L 40W/835/XEW/4P/IS 25W
25
2G11
25
3500K
22½
20,000
24,000
2600
2470
82
95%
209155
PL-L 40W/841/XEW/4P/IS 25W
25
2G11
25
4100K
22½
20,000
24,000
2600
2470
82
95%
© 2008 Philips Lighting Company. All rights reserved.
Printed in USA 06/08
P-5886-A
www. philips.com
Philips Lighting Company
200 Franklin Square Drive
P.O. Box 6800
Somerset, NJ 08875-6800
1-800-555-0050
A Division of Philips Electronics North America Corporation
Philips Lighting
281 Hillmount Road
Markham, Ontario
Canada L6C 2S3
1-800-555-0050
A Division of Philips Electronics Ltd.
1) Rated average life is the length of operation (in hours) at which point an average of 50% of a large sample of lamps will still be operational and 50% will not.
2) Average life under specified test conditions with lamps turned off and restarted no more frequently than once every 3 operating hours. Lamp life is appreciably longer if lamps are started less frequently.
3) Average life under engineering data with lamps turned off and restarted once every 12 operating hours.
4) Approximate initial lumens.The lamp lumen output is based upon lamp performance after 100 hours of operating life, when the output is measured during operation on a reference ballast under standard laboratory
conditions. For expected lamp lumen output, commercial ballast manufacturers can advise the appropriate ballast factor for each of their ballasts when they are informed of the designated lamp.The ballast factor is a
multiplier applied to the designated lamp lumen output.
5) Design lumens are the approximate lamp lumen output at 40% of the lamp’s rated average life.This output is based upon measurements obtained during lamp operation on a reference ballast under
standard laboratory conditions.
Above specifications are subject to change without notice.
Printed on chlorine free paper from Sappi Fine Paper mills, who are accredited with EMAS environmental certification.
Sappi claims that the pulp used in the manufacture of Magno Dull paper is derived from environmentally certified forests.
Rated Average Life in Hours
Rated Average Life in Hours
BASED ON 3 HOURS PER START
2
20,000
BASED ON 12 HOURS PER START
3
24,000
Instant Start Ballast
0
5,000
10,000
15,000
20,000
25,000
Rated Average Life
Philips Energy Advantage PL-L 25W Lamps
Dimensions
A––––––––––––––––––––––––21.3"/540mm
B ––––––––––––––––––––––––22.2"/572mm
C ––––––––––––––––––––––22.5"/571.5mm
D –––––––––––––––––––––––––1.5"/38mm
D1 ––––––––––––––––––––––––0.7"/18mm