INSTALLATION INSTRUCTION 83
DP 6000 DIGITAL PAGING SYSTEM
Page 3/29
February 1997
RECEIVER MODULE
PCB Connector
Antenna
Fig.3
TRANSMITTER MODULE
Solder spot
Aerial wire
connection
Antenna
securing
PCB connector
Fig.4
Recall
Alarm
18
23
23
20
21
23
22
23
memory stack (0-9)
2.1 MOUNTING
To open the transceiver a special TORX(TM) type screw
driver (TX8) should be used.
Mount the HF receiver and transmitter as follows:
1. Open the transceiver by removing the 4 panel mounting
screws located at the rear side of the transceiver ( Fig.2
(23)).
2. With reference to Figs. 5 and 6 mount the receiver
module, using the modules PCB connector (Fig. 3).
3. With reference to Figs 5 and 6 mount the transmitter
module (Fig.4) using the modules PCB connector. Fit the
antenna attachment screw (ensure that the hole in the
attachment screw is in the correct position to allow the
back-panel screw to enter).
4. Mount the securing brackets using the two securing screws
(Fig.6).
5. For IP64, smear a small amount of acid free vaseline on the
rear panel sealing ring.
6. Close the back-panel using the five box screws.
7. Screw the antenna in to its mounting.
Fig.2