Specifications

Finish: Chassis exterior

–white baked polyester enamel. Cavity- white baked

polyester enamel minimum 86% reflectance. Rust preventative undercoating

Frame: 

Extruded aluminum with soft white polyester powder coat finish.

Lens: 

One-piece vacuum formed white acrylic containing 25% DR with 

decorative trim.

Electrical:

Thermally protected class “P” ballast C.B.M. approved, no PCB.  If

KO is within 3” of ballast, use wire suitable for at least 90°.

Labels: 

I.B.E.W./UL and ULc Listed.

Belmont Spill Frame  

BESF2X2

Page 2 of 2       

Architectural Surface Fluorescent

15-1/2" Wide, 26" Length, 4 Lamp T8 or 2 Lamp TT5

      Ordering  Information

Length

Shielding

Chassis

Finish

Lamp

Ballast

10THD

2'

BESF2X2

BE2B417UNVHI

Black

4-T8

2 - 2 Lamp

HI

2'

BESF2X2

BE2W417UNVHI

White

4-T8

2 - 2 Lamp

HI

2'

BESF2X2

BE2B417UNVH4

Black

4-T8

1 - 4 Lamp Elec.

H4

2'

BESF2X2

BE2W417UNVH4

White

4-T8

1 - 4 Lamp Elec.

H4

TT5

2'

BESF2X2

BE2B2FTUNVIB

Black

2-TT5

1 - 2 Lamp Elec.

IB

2'

BESF2X2

BE2W2FTUNVIB

White

2-TT5

1 - 2 Lamp Elec.

IB

NOTE:

Chassis and shielding shown are stock items.

Chassis
Model No. BE2W417UNVH4

with shielding BESF2X2

Chassis
Model No. BE2W2FTUNVIB

with shielding BESF2X2

BE

Options:

Add appropriate suffix to catalog no.,

ie: (GLR)  

Consult factory for additional options.

Belmont

Architectural

Fluorescent

2

Fixture Width:

= 15 1/2¨ wide

Body Finish:

= White

= Black

Lamp:

(By Others)

17 

= T8 17W

FT 

= TT5 40W

(Nominal 24")

Lamp

Quantity

= 4 Lamp T8

= 2 Lamp TT5

UNV

Ballast Type:

<

10THD

2 - 2 Lamp Elec. T8

HI †

(17 Watt)

1 - 4 Lamp Elec. T8

H4 †

(17 Watt)

2 - Lamp Elect. TT5

IB †

(40 Watt)

†Instant Start (

UNV

)

Voltage:

UNV

=120-277

Chassis Code:

NOTE:

Chassis and shielding are packed in separate cartons. 

When ordering, enter as separate line items.

LER = FP - 48.0      IW - 54.3      BF - 0.88
Comparative yearly lighting energy cost per

1000 lumens = $5.00

Report Number: G2007088
Lamp: (4) F17T8
Luminaire: 2X2 Belmont Spill Frame
Ballast: ICN-4P32-SC
Report is based on 1375 Lumens per lamp.

Efficiency: 53.9%

CIE Type - Direct
Plane:

0-Deg

90-Deg

Spacing Criteria:

1.2

1.2

Shielding Angles:

90

90

Plane:

0-Deg

90-Deg

Luminous Length:

25.200

15.000

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG.

45-DEG.

90-DEG.

45

3459.

3415.

3363.

55

3184.

3131.

3082.

65

2785.

2754.

2711.

75

2129.

2243.

2290.

85

1148.

1890.

1933.

LUMINANCE DATA IN CANDELA/SQ. METER

COEFFICIENTS OF UTILIZATION –

ZONAL CAVITY METHOD. EFFECTIVE 
FLOOR CAVITY REFLECTANCE 0.20

0

RC

80

50

30

RW 70 50 30 50 30 10 50 30 10

0

1 58 55 53 51 49 48 49 47 46

0

2 53 48 44 45 42 39 43 40 38

0

3 48 42 38 39 36 33 38 35 32

0

4 44 37 33 35 31 28 33 30 27

0

5 40 33 28 31 27 24 30 26 24

0

6 37 30 25 28 24 21 27 24 21

0

7 35 27 22 26 22 19 25 21 18

0

8 32 25 20 23 20 17 23 19 16

0

9 30 23 18 22 18 15 21 17 15

10 28 21 17 20 16 14 19 16 13

0.0

45.0

90.0

FLUX

0

1000

1000

1000

5

993

994

994

95

15

952

955

956

270

25

877

883

886

407

35

773

779

784

488

45

645

653

659

503

55

497

506

515

452

65

337

350

361

346

75

175

199

218

210

85

47

90

105

93

90

25

55

72

CANDELA DISTRIBUTION

ZONE

LUMENS % LAMP

% FIXT

0

0-

0

30

771

14.0

26.9

0

0-

0

40

1258

22.9

43.9

0

0-

0

60

2214

40.3

77.3

0

0-

0

90

2863

53.9

100.0

90-180

000

0

0.0

00

0.0

0

0-180

2863

53.9

100.0

ZONAL LUMEN SUMMARY

LER = FP - 47.6      IW - 64.75      BF - 0.88
Comparative yearly lighting energy cost per

1000 lumens = $5.04

Report Number: G2008136
Lamp: (2) TT5 40W
Luminaire: 2X2 Belmont Spill Frame
Ballast: ICN-2TTP40-SC
Report is based on 3300 Lumens per lamp.

Efficiency: 53.1%

CIE Type - Direct
Plane:

0-Deg

90-Deg

Spacing Criteria:

1.3

1.3

Shielding Angles:

90

90

Plane:

0-Deg

90-Deg

Luminous Length:

25.200

15.000

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG.

45-DEG.

90-DEG.

45

4996.

5053.

5098.

55

4807.

4893.

4956.

65

4477.

4636.

4753.

75

3898.

4348.

4677.

85

3292.

5813.

6687.

LUMINANCE DATA IN CANDELA/SQ. METER

0.0

45.0

90.0

FLUX

0

1188

1188

1188

5

1182

1182

1184

113

15

1137

1141

1142

322

25

1053

1059

1062

488

35

936

943

948

590

45

788

797

804

615

55

615

626

634

559

65

422

437

448

432

75

225

251

270

265

85

64

113

130

118

90

30

69

87

CANDELA DISTRIBUTION

ZONE

LUMENS % LAMP

% FIXT

0

0-

0

30

923

14.0

26.3

0

0-

0

40

1513

22.9

43.2

0

0-

0

60

2688

40.7

76.7

0

0-

0

90

3503

53.1

100.0

90-180

000

0

0.0

00

0.0

0

0-180

3503

53.1

100.0

ZONAL LUMEN SUMMARY

For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 a Philips Group

Section 3A/Folio H10-11 Rev. A

Job Information  

Type:

Lightolier is a Philips group brand

COEFFICIENTS OF UTILIZATION –

ZONAL CAVITY METHOD. EFFECTIVE 
FLOOR CAVITY REFLECTANCE 0.20

0

RC

80

50

30

RW 70 50 30 50 30 10 50 30 10

0

1 57 55 52 51 49 48 49 48 46

0

2 52 47 44 44 42 39 43 40 38

0

3 47 42 37 39 36 33 38 35 32

0

4 43 37 32 35 31 28 33 30 27

0

5 40 33 28 31 27 24 30 26 24

0

6 37 29 25 28 24 21 27 23 21

0

7 34 27 22 25 21 18 25 21 18

0

8 32 24 20 23 19 16 23 19 16

0

9 30 22 18 21 18 15 21 17 15

10 28 21 16 20 16 13 19 16 13

Reviews: