background image

English

3

The Camera series (LTC0500/60 and LTC0600/60) are provided with a correct polarized
mains power plug for 120V supply mains.The Camera can accept ‘nominal’ voltage
anywhere from 100-240V and can operate on either a 50 or 60Hz system.
If the Camera will be connected to an other mains voltage than 120Vac, use the PROPER
mains power connector for that mains voltage.
In case of using a mains voltage of 240V use a correct adapter plug with the following
specifications: NEMA plug type 2-15P, 2 pole 2 wire, 15 Amps-250V, or contact qualified
Service personnel. See also item Important Safeguards.

1)  Read Instructions - All the safety and operating instructions should be read before the

unit is operated.

2)  Retain Instructions - The safety and operating instructions should be retained for

future reference.

3)  Heed Warnings - All warnings on the unit and in the operating instructions should be

adhered to.

4)  Follow Instructions - All operating and use instructions should be followed.
5)  Cleaning - Unplug the unit from the outlet before cleaning. Do not use liquid cleaners

or aerosol cleaners. Use a damp cloth for cleaning.

6)  Attachments - Do not use attachments not recommended by the product

manufacturer as they may cause hazards.

7)  Water and Moisture - Do not use this unit near water - for example, near a bath tub,

wash bowl, kitchen sink, or laundry tub, in a wet basement, near a swimming pool, in an
unprotected outdoor installation, or any area which is classified as a wet location.

8)  Accessories - Do not place this unit on an unstable stand, tripod, bracket, or mount.

The unit may fall, causing serious injury to a person and serious damage to the unit.
Use only with a stand, tripod, bracket, or mount recommended by the manufacturer, or
sold with the product. Any mounting of the unit should follow the manufacturer’s
instructions, and should use a mounting accessory recommended by the manufacturer.
An appliance and cart combination should be moved with care. Quick stops, excessive
force, and uneven surfaces may cause the appliance and cart combination to overturn.

FCC Statement

2

This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received including interference that may

cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules.These limits are designed to provide
reasonable protection against harmful interference in a residential installation.

This equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

WARNING
YOU ARE CAUTIONED THAT CHANGES OR MODIFICATIONS NOT EXPRESSLY
APPROVED BY THE PART RESPONSIBLE FOR THE COMPLIANCE COULD VOID YOUR
AUTHORITY TO  OPERATE THE  EQUIPMENT.

This label may appear on the product.

The lightning flash with an arrowhead symbol, within an equilateral triangle, is
intended to alert the user to the presence of uninsulated ‘dangerous voltage’
within the product’s enclosure that may be of sufficient magnitude to constitute a
risk of electric shock to persons.

The exclamation point within an equilateral triangle is intended to alert the user
to presence of important operating and maintenance (servicing) instructions in
the literature accompanying the appliance.

WARNING

TO PREVENT FIRE OR SHOCK HAZARD, DO

NOT EXPOSE THIS UNIT TO RAIN OR

MOISTURE.

Important Safeguards

Summary of Contents for LTC0500

Page 1: ...ite Camera Installation manual Installationsanleitung Manuel d installation Manuale d installazione Installatiehandleiding Manual de instalación LTC0500 Subject to changes without notice Philips I C 1999 3122 165 21862 ...

Page 2: ...________________________________________ 12 7 4 Synchronisation connection Sync ____________________________ 12 7 5 Remote control connection RS 232 __________________________ 12 8 Mounting the camera________________________________________ 13 9 Operating controls and features ______________________________ 13 9 1 How to set up your camera ________________________________ 13 9 2 Function set up __...

Page 3: ...s may cause the appliance and cart combination to overturn FCC Statement 2 This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the li...

Page 4: ...f any kind into this unit through openings as they may touch dangerous voltage points or short out parts that could result in a fire or electric shock Never spill liquid of any kind on the unit 16 Servicing Do not attempt to service this unit yourself as opening or removing covers may expose you to dangerous voltage or other hazards Refer all servicing to qualified service personnel 17 Damage Requ...

Page 5: ...External V lock H V lock Software OSD On Screen Display text is available for camera ID and set up feedback RS 232 communication Automatic image quality enhancement Auto Light Control ALC Electronic Light Control ELC allows the use of manual lenses for indoor use Non Linear Processing NLP Auto Black and Back Light Compensation BLC provide superb dynamic contrast handling for the best picture resul...

Page 6: ...ng the LVL button again or twice if the OSD menu has disappeared Use buttons for adjusting desired video level OSD indication on the right displays video level 2 1 4 3 VIDEO IRIS 4 1 2 3 2 1 4 3 DC IRIS 4 1 2 3 1 Damping coil 2 Damping coil 3 Drive coil 40 mA max 4 Drive coil Ground 5 Mounting the lens The camera supports Manual Iris Video Iris and DC Iris lenses The use of Video or DC Iris lenses...

Page 7: ...era input terminal The supply connection is polarity independent Voltage range rated 11 36 V DC Power dissipation 8 W Start up current 1 A 24 V AC 12 V DC 1 2 Video Sync Balance RS232 Video Sync Balance RS232 1 2 Mains voltage models LTC0500 50 CCIR LTC0500 60 EIA Low voltage models LTC0500 10 CCIR LTC0500 20 EIA 6 Back focus adjustment The back focus screw is an endless screw that turns the back ...

Page 8: ... from an external source sync input BNC The camera automatically configures for the applied external synchronisation For adjustment see chapter 9 7 5 REMOTE CONTROL CONNECTION RS 232 The camera can be set up using an optional Windows based PC software tool This product can be ordered separately Functions available with this software tool are AGC manual Automatic Electronic Light Control ELC Dynami...

Page 9: ...00 000 The auto setting automatically optimizes the shutter time according to the light conditions 9 2 5 Linelock setting Use this button to select between internal synchronisation and linelock The camera will switch to external lock when an external lock source is connected see 9 2 6 9 2 8 When DC is supplied the camera selects internal synchronisation 9 2 6 Linelock Phase This function is active...

Page 10: ... drive level 1 V p p 2 Selection by PC software LTC0650 00 16 10 Specifications 9 2 7 H Phase This function is active when the camera operates with external synchronisation H V Use the H phase setting to adjust Horizontal timing differences when cameras are H V synchronised Input standard CVBS synchronisation signals 9 2 8 ext V Phase This function is active when the camera operates with external ...

Page 11: ...and power cable with polarized US plug Power supply input terminals are isolated from video output terminals ENVIRONMENTAL Temperature range Operating 10 to 55 ºC 14 to 131 F Storage 40 to 70 ºC 40 to 158 F Operating Humidity 5 to 93 non condensing Electro Magnetic Compatibility Emission EN 50081 1 FCC Part 15 Class B Immunity EN 50130 4 Safety LTC 0500 10 and 50 EN 60950 LTC 0500 20 and 60 UL 650...

Reviews: