Job Information 

Type:

Job Name:

Cat. No.:

Notes:

Features

Illumination:

 Illumination 

is provided by two high-

performance 5.5 W, 6 VDC 

MR16-style halogen lamps. 

Lamps are held in an attractive 

molded swivel assembly, and 

are fully adjustable.

Housing: 

The high-abuse 

housing, backplate and 

electronics shell are molded 

from high-impact, F1 rated, 

GE Lexan

®

 polycarbonate. All 

injection molded components 

meet the UL 94 V-0, 5 VA 

flame retardant standard for 

emergency lighting products. 

All units are supplied standard 

with a UL damp location 

listing and tamperproof screw 

kit. Optional wet location 

listed products include a fully 

gasketed cover. Installation 

is simplified by the use of a 

snap-together backplate and 

housing. When installed with 

the supplied tamperproof 

screw kit, removal from 

mounting surface, or removal 

of outer protective cover is 

not possible under normal 

service conditions without the 

use of a torx T-15 bit. Utility 

supply is completed by use of a 

modular plug-in wiring harness. 

A convenient knockout is 

also made available in the top 

right section of product to 

accommodate 1/2” conduit 

(damp location listed units 

only).

Operating Temperature 

Range:

 Damp location

50°F (10°C) to 104°F (40°C)

Wet location

41°F (5°C) to 104°F (40°C) 

Wet location with heater

-4°F (-20°C) to 104°F (40°C)

Electronics: 

120/277 VAC 

dual voltage input with surge-

protected, solid-state, fully 

automatic, voltage regulated 

charger. Charging system is 

complete with low voltage 

disconnect, AC lockout, 

brownout protection and 

combination indicator lamp and 

illuminated test switch.

Electrical Specifications: 

0.05 A (120 VAC)

0.30 A (120 VAC) with heater 

option

0.02 A (277 VAC)

0.13 A (277 VAC) with heater 

option

Battery

Maintenance free, sealed 

lead calcium battery has an 

expected service life of 5 

years. Upon utility power 

failure or brownout, the unit 

shall automatically provide 

emergency battery power and 

maintain the stated illumination 

level and output wattage for a 

minimum period of 90 minutes.

Code Compliance

UL 924, UL damp location, 

and optional UL wet location 

listed. NFPA 101, NEC, BOCA, 

OSHA and IBC illumination 

standards. Meets ADA 

specifications for wall mounted 

lighting fixtures.

Warranty

Three year full electronics 

warranty. One year full plus 

four year prorated lead calcium 

battery warranty.