background image

SET

UP

 

OPTIONS

 

For

 

best

 

result

 

set

 

each

 

desirable

 

option

 

in

 

the

 

order

 

listed

 

below.

 

 

PHIL

IPS

WARRANTY

 

STATEMENT

 

The

 

Philips

 

OccuSwitch™

 

Wireless

 

products,

 

when

 

properly

 

installed

 

and

 

under

 

normal

 

conditions

 

of

 

use

 

(without

 

over

load,

 

abuse

 

or

 

alteration),

 

is

 

warranted

 

to

 

you,

 

the

 

original

 

user,

 

for

 

a

 

period

 

of

 

two

 

(2)

 

years

 

from

 

the

 

date

 

of

 

original

 

purchase,

 

to

 

be

 

free

 

from

 

defects

 

in

 

materials

 

and

 

workman

ship.

 

If

 

during

 

the

 

warranty

 

period

 

you

 

believe

 

the

 

purchased

 

product

 

or

 

any

 

part

 

thereof

 

has

 

such

 

a

 

defect,

 

you

 

must

 

return

 

the

 

product

 

(or

 

part)

 

at

 

your

 

cost

 

during

 

such

 

period,

 

with

 

proof

 

of

 

purchase

 

(or

 

if

 

installed

 

by

 

a

 

third

 

party

 

a

 

written

 

explanation

 

of

 

installation

 

transaction

 

with

 

proof

 

of

 

date),

 

to

 

Philips

 

Lighting

 

Electronics

 

N.A

 

(

1

800

372

3331

 

/

 

www.philips.com/advance

),

 

for

 

repair

 

or

 

replacement

 

(or

 

to

 

an

 

authorized

 

Philips

 

Lighting

 

Electronics

 

N.A.

 

supplier

 

which

 

agrees

 

in

 

advance

 

to

 

handle

 

the

 

return

 

and

 

replacement

 

by

 

factory

 

authorization).

 

If

 

the

 

product

 

or

 

part

 

is

 

found

 

by

 

Philips

 

to

 

have

 

been

 

defective

 

in

 

material

 

or

 

workmanship

 

it

 

will

 

be

 

repaired

 

or

 

replaced

 

(as

 

deemed

 

necessary

 

by

 

Philips

 

Lighting

 

Electronics

 

N.A.),

 

and

 

the

 

replacement

 

will

 

be

 

returned

 

to

 

you

 

free

 

of

 

charge.

 

The

 

original

 

user

 

is

 

solely

 

responsible

 

for

 

any

 

costs

 

associated

 

with

 

removal

 

and

 

re

installation

 

of

 

the

 

prod

uct

 

and

 

shipping

 

to

 

Philips

 

Lighting

 

Electronics

 

N.A.

 

or

 

its

 

authorized

 

supplier.

 

 

Troubleshooting

 

System

 

The

 

lights

 

turn

 

off

 

too

 

quickly:

  

The

 

system

 

has

 

a

 

smart

 

timer

 

that

 

adjust

 

the

 

off

 

delay

 

time

 

automati

cally.

  

To

 

change,

 

set

 

sensor’s

 

minimum

 

timeout

 

dial

 

to

 

a

 

higher

 

value.

 

The

 

system

 

is

 

set

 

to

 

Manual

 

ON,

 

but

 

lights

 

turn

 

on

 

automatically:

  

When

 

entering

 

the

 

area

 

within

 

5

 

min

utes

 

after

 

lights

 

turning

 

off,

 

the

 

system

 

assumes

 

that

 

turning

 

off

 

was

 

undesired

 

and

 

turn

 

ON

 

the

 

lights.

 

The

 

system

 

shows

 

that

 

a

 

linked

 

device

 

is

 

missing:

  

When

 

a

 

device

 

is

 

missing,

 

use

 

the

 

ACTION

  

#1

 

menu

 

to

 

show

 

all

 

linked

 

devices.

  

If

 

a

 

sensor

 

does

 

not

 

show

 

as

 

linked,

 

its

 

battery

 

may

 

need

 

to

 

be

 

replaced.

  

If

 

this

 

does

 

not

 

resolve

 

the

 

error,

 

reset

 

all

 

devices

 

and

 

link

 

them

 

again.

 

The

 

lights

 

immediately

 

turn

 

ON

 

after

 

being

 

turned

 

off

 

The

 

sensor

 

may

 

be

 

placed

 

too

 

close

 

to

 

a

 

(heat

 

generat

ing)

 

light

 

source.

 

Move

 

the

 

sensor

 

to

 

a

 

better

 

location.

 

Reset

 

the

 

device

 

to

 

factory

 

defaults

 

To

 

reset

 

the

 

device

 

to

 

its

 

factory

 

default

 

configuration:

 

Press

 

and

 

hold

 

the

 

link

 

button

 

on

 

the

 

device

 

for

 

more

 

than

 

10

 

seconds.

 

Release

 

the

 

button

 

when

 

the

 

red

,

 

yellow

 

and

 

green

 

LED

s

 

light

 

briefly.

 

Maintenance

 

Routine

 

lamp

 

replacement

 

To

 

safely

 

do

 

a

 

routine

 

lamp

 

replacement,

 

on

 

all

 

switches,

 

firmly

 

press

 

the

 

OFF

side

 

until

 

the

 

rocker

 

clicks

 

into

 

the

 

position

 

where

 

a

 

yellow

 

band

 

with

 

“OFF”

 

becomes

 

visible.

 

The

 

load

 

is

 

now

 

temporarily

 

separated

 

from

 

the

 

line

 

voltage

 

by

 

an

 

air

 

gap

 

switch,

 

so

 

you

 

can

 

safely

 

replace

 

the

 

lamp.

 

  

WARNING

:

  

If

 

the

 

air

 

gap

 

function

 

is

 

not

 

used,

 

the

 

power

 

may

 

be

 

switched

 

ON

 

unintentionally

 

by

 

the

 

sensor

 

while

 

replac

ing

 

the

 

lamp.

 

This

 

could

 

result

 

in

 

serious

 

injury

 

or

 

death.

 

  

WARNING

:

  

For

 

any

 

procedure

 

other

 

than

 

lamp

 

replacement,

 

power

 

must

 

be

 

disconnected

 

at

 

the

 

main

 

electric

 

panel.

 

Use

 

approved

 

LOCK

OUT/TAG

OUT

 

proce

dures

 

to

 

insure

 

that

 

the

 

circuit

 

is

 

not

 

acti

vated

 

accidently.

  

Working

 

with

 

power

 

ON

 

is

 

unsafe

 

and

 

can

 

result

 

in

 

serious

 

injury

 

or

 

death.

 

Replacing

 

the

 

sensor

 

battery

 

CAUTION:

 

You

 

must

 

have

 

read

 

the

 

SAFETY

 

section

 

before

 

replacing

 

the

 

battery.

 

To

 

replace

 

the

 

battery

 

of

 

the

 

sensor:

 

1.

 

Rotate

 

the

 

sensor

 

counterclockwise

 

to

 

remove

 

from

 

mounting

 

plate.

 

2.

 

In

 

a

 

safe

 

and

 

dry

 

place,

 

remove

 

the

 

old

 

battery

 

and

 

insert

 

the

 

new

 

battery.

 

CAUTION:

 

Use

 

only

 

high

quality

 

AA

 

size

 

3.6

 

V

 

DC

 

lithium

thionyl

 

chlo

ride

 

batteries

 

with

 

the

 

sensor.

  

Using

 

improperly

 

rated

 

batteries

 

may

 

damage

 

the

 

sensor.

 

3.

 

Place

 

the

 

sensor

 

back

 

on

 

the

 

mounting

 

plate

 

and

 

rotate

 

clock

wise

 

to

 

fix

 

it.

 

4.

 

Dispose

 

of

 

used

 

battery

 

properly.

 

DO

 

NOT

 

throw

 

in

 

trash.

 

Keep

 

away

 

from

 

children.

 

Do

 

not

 

disassemble

 

and

 

do

 

not

 

dispose

 

of

 

in

 

fire.

 

 

4

 

CONFIGURE,

 

TEST

 

&

 

FINISH

 

Configure

 

When

 

all

 

sensors

 

and

 

wall

 

devices

 

are

 

linked,

 

you

 

can

 

change

 

the

 

operation

 

settings.

 

This

 

is

 

done

 

at

 

any

 

wall

 

device;

 

the

 

settings

 

are

 

automatically

 

sent

 

to

 

the

 

other

 

devices

 

in

 

the

 

rooms

 

network.

 

You

 

can

 

select

 

the

 

fol

lowing

 

options

 

in

 

the

 

Configuration

 

and

 

Action

 

menus.

 

(Config

 

#4)

 

Set

 

High

 

End

 

Level

 

‐ 

If

 

you

 

want

 

to

 

limit

 

the

 

maxi

mum

 

output

 

from

 

a

 

dimmer

 

set

 

the

 

desired

 

high

 

end

 

level

 

and

 

run

 

through

 

Configuration

 

Menu

 

(Yellow)

 

#4.

 

After

 

successfully

 

installing

 

and

 

linking

 

the

 

sensors

 

and

 

wall

 

devices

 

you

 

can

 

change

 

settings

 

to

 

customize

 

the

 

system

 

to

 

the

 

needs

 

of

 

the

 

user.

  

Configuration

 

and

 

set

up

 

To

 

dim

 

up,

 

press

 

and

 

hold

 

the

 

ON

 

button

  

To

 

dim

 

down

 

,

 

press

 

and

 

hold

 

the

 

OFF

 

button

  

Menu

 

operations

 

use

 

CONFIG

 

and

 

LINK/ACTION

 

but

tons

 

as

  

described

 

in

 

the

 

Configuration

 

(YELLOW)

 

and

 

Action/RED

 

menus

 

below.

 

CONFIGURATION

 

(Yellow)

 

Menu

 

for

 

both

 

Wall

 

Devices

  ‐ 

Press

 

CONFIG

 

button

 

(Long

 

to

 

enter)

 

(Short

 

for

 

next

 

item)

 

Item

 

Description

 

Action

 

Store

  

Setting

 

Start

 

Yellow

 

Spike

 

(…/…)

 

Exist

 

Long

 

Press

 

CONFIG

 

to

 

exit

 

 

N/A

 

1

 

Yellow

 

Blinks

 

(…1…)

 

Manual

 

ON/

 

Auto

 

OFF

 

(Title

 

24)

 

Long

 

CONFIG

 

=

 

Manual

 

ON

 

Long

 

ACTION

 

=

 

Auto

 

ON

 

 

Automatic

 

2

 

Yellow

 

Blinks

 

(…1..1…)

 

Multi

Way

 

Configuration

 

Long

 

CONFIG

 

to

 

create

 

multi

way

 

group

 

Long

 

CONFIG

 

3

 

Yellow

 

Blinks

 

(…1..1..1…)

 

Dimmer

 

Response

 

Curve

 

(Dimmer

 

Only)

 

Long

 

CONFIG

 

to

 

change

 

response

 

curve

 

Long

 

CONFIG

 

4

 

Yellow

 

Blinks

 

(…1..1..1..1…)

 

Set

 

High

 

End

 

Level

 

(Task

 

Tuning)

 

(Dimmer

 

Only)

 

Long

 

CONFIG

 

=

 

Sets

 

maximum

 

dim

 

level

 

Long

 

ACTION

 

=

 

Return

 

to

 

100%

 

Automatic

 

Indicator

 

ACTION

 

(Red)

 

Menu

 

for

 

Sensors

 

and

 

Wall

 

Devices

‐ 

Press

 

LINK/ACTION

 

button

 

(Long

 

to

 

enter)

 

(Short

 

for

 

next

 

item)

 

Item

 

Indicator

 

Description

 

Wall

 

Switch

 

Wall

  

Dimmer

 

Multi

Sensor

 

Occ.

 

Sensor

 

Action

 

Results

 

Start

 

Red

 

Spike

 

(…/…)

 

Exit

 

X

 

X

 

X

 

X

 

Long

  

LINK/ACTION

 

to

 

exit

 

  

1

 

Red

 

Blinks

 

(…1…)

 

Show

 

Linked

 

Device

 

X

 

X

 

X

 

X

 

Long

  

LINK/ACTION

 

to

 

start

 

 

Automatic

 

2

 

Red

 

Blinks

 

(…1..1…)

 

Test

 

Sensor

 

Coverage

 

X

 

X

 

X

 

X

 

Long

 

LINK/ACTION

  

to

 

Start

 

Short

 

LINK/ACTION

 

on

 

sensor

 

to

 

Finish

 

 

3

 

Red

 

Blinks

 

(…1..1..1…)

 

Calibrate

 

Daylight

 

dimming

 

set

point

 

(<

 

1

 

min.

 

process)

 

N/A

 

X

 

X

 

X

 

Long

 

LINK/ACTION

  

to

 

Start

 

Automatic

 

4

 

Red

 

Blinks

 

(…1..1..1..1…)

 

Daylight

 

Hold

 

Back

 

X

 

N/A

 

X

 

X

 

Long

 

LINK/ACTION

 

to

 

Start

 

Automatic

 

5

 

Red

 

Blinks

 

(…1..1..1..1..1…)

 

Channel

 

Change

 

X

 

X

 

X

 

X

 

Long

 

LINK/ACTION

 

to

 

Start

 

 

Automatic

 

SET

UP

 

hint

 

Use

 

a

 

small

 

screw

 

drive

 

or

 

similar

 

device

 

to

 

push

 

the

 

Menu

 

buttons.

 

Short

 

button

 

press

 

:

  

<

 

1

 

second

 

Long

 

button

  

press:

  

>

 

2

 

seconds

 

Test

 

sensor

 

coverage

 

Once

 

all

 

devices

 

are

 

installed,

 

linked

 

and

 

configured,

 

you

 

can

 

test

 

the

 

installation

 

to

 

ensure

 

that:

 

The

 

sensor

 

detects

 

motion

 

in

 

the

 

workspace.

 

Test

 

to

 

make

 

sure

 

sensor

 

does

 

not

 

pick

 

up

 

motion

 

from

 

adja

cent

 

areas,

 

e.g.

 

the

 

hallway.

  

This

 

can

 

be

 

done

 

at

 

any

time,

 

see

 

ACTION

 

Menu

 

for

 

steps.

 

(Config

 

#2)

 

Multi

Way

 

Configuration

 ‐ 

Several

 

switches

 

and

 

dimmers

 

can

 

be

 

put

 

in

 

a

 

group

 

that

 

control

 

each

 

oth

ers

 

load

 

when

 

operated

 

manually.

  

You

 

can

 

create

 

several

 

independent

 

control

 

groups

 

linked

 

to

 

the

 

ceiling

 

sensors.

    

1.

 

Use

 

CONFIG

 

menu

 

item

 

2

 ‐ 

All

 

wall

 

devices

 

will

 

start

 

to

 

blink:

 

GREEN

 

is

 

included,

 

RED

 

is

 

excluded.

 

2.

 

Tap

 

the

 

ON

 

button

 

to

 

include,

 

OFF

 

bottom,

 

to

 

exclude.

   

3.

 

 

Long

  

CONFIG

 

button

 

press

 

will

 

save

 

the

 

settings.

 

4.

 

Repeat

 

from

 

step

 

1

 

on

 

different

 

wall

 

devices

 

to

 

form

 

more

 

groups.

 

(Config

 

#3)

 

Dimmer

 

Response

 

Curve

 

‐ 

If

 

the

 

Daylight

 

dimming

 

response

 

is

 

too

 

aggressive

 

the

 

Dimmer

 

can

 

be

 

set

 

to

 

respond

 

less

 

to

 

daylight.

  

If

 

the

 

response

 

is

 

too

 

low

 

the

 

dimmer

 

can

 

be

 

set

 

to

 

react

 

more

 

to

 

additional

 

day

light.

 

Dimmer

 

Response

 

Curve

 

1

 

Blink

 ‐ 

Top

 

LED

 

50%

 

2

 

Blink

 ‐ 

2nd

 

LED

 

20%

 

3

 

Blink

 ‐ 

3rd

 

LED

 

10%

 

4

 

Blink

 ‐ 

4th

 

LED

 

(default)

 

Straight

 

Line

 

5

 

Blink

 ‐ 

5th

 

LED

 

+10%

 

6

 

Blink

 ‐ 

6th

 

LED

 

+20%

 

7

 

Blink

 ‐ 

Bottom

 

LED

 

+50%

 

(Action

 

#3)

 

Daylight

 

Calibration

  

(FIRST

 

TIME)

 ‐

 

Only

 

one

 

sensor

 

can

 

be

 

linked

 

to

 

one

 

Switch

 

(Hold

back)

 

or

 

one

 

Dimmer

 

(continuous

 

dimming)

 

for

 

Daylight

 

Regulation.

  

The

 

first

 

time

 

the

 

daylight

 

Action

 

Menu

 

is

 

activate

 

the

 

system

 

unlocks

 

and

 

links

 

the

 

senor

 

to

 

the

 

wall

 

device

 

for

 

Daylight

 

regulation.

 

This

 

can

 

be

 

done

 

from

 

the

 

floor

 

before

 

mounting

 

the

 

sensor.

   

Next

 

time

 ‐ 

After

 

the

 

first

 

activation

 

and

 

calibration

 

the

 

daylight

 

menu

 

can

 

be

 

run

 

from

 

the

 

wall

 

device

 

to

 

recalibrate

 

the

 

daylight

 

settings.

   

Calibration

 

process

 ‐ 

When

 

the

 

sensor

 

and

 

the

 

wall

 

device

 

enter

 

calibration

  

mode

 

the

  

Tip:

 

It

 

is

 

important

 

that

 

the

 

daylight

 

is

 

constant

 

and

 

is

 

not

 

too

 

bright

 

(no

 

need

 

to

 

calibrate

 

in

 

the

 

dark).

 

1.

 

Use

 

dimmer

 

to

 

dim

 

to

 

the

 

required

 

light

 

level

 

using

 

light

 

meter

 

on

 

the

 

work

 

surface.

 

2.

 

Go

 

into

 

action

 

menu

 

on

 

the

 

sensor

 

to

 

select

 

Calibration

 

daylight

 

regulation

 

set

point

 

menu

 

item.

 

(Yellow

 

LED

 

starts

 

Blinking)

 

3.

 

Clear

 

the

 

area

 

under

 

the

 

light

 

sensor

 

(walk

 

away).

 

4.

 

Automatic

 

Configuration

 

will

 

start

 

in

 

about

 

a

 

minute.

  

All

 

dimmers

 

in

 

the

 

system

 

go

 

to

 

100%,

 

then

 

switch

 

off.

 

The

 

green

 

LED

 

on

 

the

 

device

 

turns

 

on.

 

Sensor

 

confirms

 

new

 

setpoint

 

using

 

green

 

LED.

 

The

 

system

 

enters

 

automatic

 

light

 

regulation

 

mode.

 

Note:

 

This

 

process

 

can

 

be

 

repeated

 

anytime

 

after

 

the

 

first

 

time

 

from

 

the

 

wall

 

device

 

without

 

touching

 

the

 

(Config

 

#1)

  

Manual

 

ON

 

/

 

AUTO

 

OFF

 

(Title

 

24

 

mode)

 ‐ 

This

 

is

 

a

 

popular

 

setting

 

for

 

maximum

 

energy

 

savings.

  

It

 

force

 

the

 

occupant

 

to

 

manual

 

activate

 

the

 

lights

 

when

 

they

 

enter

 

the

 

space

 

and

 

automatically

 

turn

 

OFF

 

the

 

light

 

when

 

they

 

leave.

  

This

 

save

 

energy

 

by

 

keep

 

the

 

lights

 

OFF

 

until

 

they

 

are

 

actually

 

needed.

 

Finish

 

OccuSwitch

 

Sensors

 

and

 

Wall

 

Devices

 

do

 

not

 

need

 

any

 

regular

 

maintenance.

  

You

 

may

 

find

 

as

 

people

 

change

 

space

 

and

 

future

 

is

 

re

arranged

 

that

 

you

 

need

 

to

 

re

calibrate

 

the

 

daylight

 

functions.

  

This

 

can

 

easily

 

be

 

done

 

at

 

floor

 

level

 

from

 

the

 

wall

 

device.

 

(Action

 

#5)

 

Channel

 

Changing

 

‐ 

In

 

some

 

building

 

environments

 

the

 

radio

 

signal

 

used

 

for

 

OccuSwitch

 

Wireless

 

may

 

encounter

 

interference

 

from

 

another

 

radio

 

device.

  

Channel

 

changing

  

activate

 

the

 

system

 

automatic

 

radio

 

analysis

 

function

 

toe

 

reset

 

the

 

channel.

  

Use

 

this

 

func

tion

 

if

 

you

 

are

 

having

 

communications

 

issues.

 

Manual

 

Mode

 ‐ 

Manual

 

mode

 

is

 

entered

 

when

 

the

 

rock

 

switch

 

is

 

pressed

 

and

 

the

 

Yellow

 

LED

 

comes

 

On.

  

After

 

sensors

 

are

 

linked,

 

the

 

system

 

will

 

return

 

to

 

auto

 

mode

 

when

 

the

 

room

 

if

 

vacant

 

and

 

the

 

delay

 

timer

 

expire.

  

To

 

return

 

to

 

Auto

 

Mode

 

Hold

 

down

 

the

 

On

 

rocker

 

until

 

the

 

Yellow

 

LED

 

goes

 

out.

  

One

 

to

 

One

 

SET

UP

 

Combined

 

Device

 

SET

UP

 

LED

 

response

 

Signals

 

Spike

 ‐ 

Very

 

short

 

blinks

 

Blink

 

 ‐ 

LED

 

switching

 

On

 

and

 

Off

 

(Action

 

#4)

 

Daylight

 

Hold

Back

 

‐ 

Similar

 

to

 

Daylight

 

calibration

 

but

 

results

 

is

 

to

 

set

 

the

 

level

 

at

 

which

 

the

 

light

 

will

 

not

 

turn

 

ON

 

automatically

 

(Hold

Back

 

level)

 

Reviews: