background image

12-24 V

RJ45

Ethernet

DyNet RS485

GND

AUX

< 20 m

+

-

ETHERNET SUPPLY IN

12/24 VDC

SERVICE

DYNET

RJ12

PDEG

SHD

GND

D +

D -

+

 V

AU

X

RS-485 DyNet 

RJ12

+

-

GND

AUX

< 20 m

RJ45

Ethernet

ETHERNET SUPPLY IN

12/24 VDC

SERVICE

RJ12

DYNET

PDEG

SHD

GND

D +

D -

+

 V

AU

X

12-24 V

≤ 

2 A

Philips Dynalite
www.lighting.philips.com/dynalite

© 2018 Philips Lighting. All rights reserved.

2

A

3

A

3

B

2

B

RS-485 DyNet Port

-

+

SHLD

GND

D +

D -

+ V

AUX

RJ45

Ethernet

µP

RJ12

12 V   

         

100 mA

24 V   

        

50 mA

SELV/Class 2

RS-485 DyNet Port

-

+

SHLD

GND

D +

D -

+ V

AUX

RJ45

Ethernet

µP

RJ12

12 V   

         

300 mA

24 V   

        

250 mA

12 V   

         

200 mA

24 V   

        

200 mA

SELV/Class 2

5

  

IEC Overvoltage Category III

  

IEC Overvoltage Category III

 

Federal Communications Commission (FCC) Compliance Notice: Radio Frequency Notice

 – This equipment has been tested and found to comply with the 

limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a 
residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, 
may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this 
equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged 
to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the 
equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an 
experienced radio/TV technician for help. Any modifications not approved by the manufacturer of this device could void the user’s authority to operate this device.

 Installation of a home and building automation and control system shall comply with HD 60364-4-41. The temperature limits and current-carrying capacities for 

the communication wires specified in HD 384.5.523 shall not be exceeded.

 This Class B digital apparatus complies with Canadian ICES-003: CAN ICES-3(B)/NMB-3(B). Cet appareil numerique de la classe B est conforme a la norme NMB-

003 du Canada: CAN ICES-3(B)/NMB-3(B).

 Do not connect inputs to mains.

DyNet RS-485

Ethernet

4

Reviews: