background image

Published by Philips Consumer Lifestyle 

Printed in the Netherlands 

© Copyright reserved 

Subject to modification

Service Manual

Philips Consumer Lifestyle

PerfectCare Viva Steam Generator

RI7035/34

Product information

Fast & powerful crease removal

Continuous steam output:  85 g/min

OptimalTEMP technology

Power: 2400 W

Safe rest

Soleplate: SteamGlide Plus

Steam boost:  150 g

Steam tip

Variable steam settings

Vertical steam

Turbo steam

Pressure:  Max 3.5 bar pump pressure

Easy to use

Cord storage:  Cord clip

Heat up time:  2 min

Hose length:  1.6 m

Hose storage:  Hose storage compartment

Open handle

Power cord length:  1.8 m

Refi ll any time

Safe for all fabrics:  Even for delicates like silks

Storage solution:  Carry lock

Water tank capacity:  1700 ml

Filling and emptying water:  Extra large fi lling hole

Sustainability

Energy saving mode

User manual:  100% recycled paper

Calc management

Calc clean reminder

Calc clean solution:  Smart Calc Clean

Suitable for tap water

Safety Information

This product meets the requirements regarding

interference suppression on radio and TV.

After the product has been repaired, it should function

properly and has to meet the safety requirements and

legal regulations as officially laid down at this moment.

Technical information

Voltage :  220 - 240 V

Weight and dimensions

Packaging dimensions (WxHxL)  :  42.7 x 23.8 x 33.5 cm

Product dimensions (WxHxL) 

:  32.2 x 19.4 x 23.6 cm

Weight of iron

:  1.24 kg

Weight of iron + base

:  4.1 kg

Accessories

Calc clean container

Version 

8

CSW-07-081-18218

Summary of Contents for PerfectCare Viva RI7035/34

Page 1: ...rics Even for delicates like silks Storage solution Carry lock Water tank capacity 1700 ml Filling and emptying water Extra large filling hole Sustainability Energy saving mode User manual 100 recycled paper Calc management Calc clean reminder Calc clean solution Smart Calc Clean Suitable for tap water Safety Information This product meets the requirements regarding interference suppression on rad...

Page 2: ...OUSING 4 DOSING HEAD 2 COVER RUBBER CAP RUBBER BUNG COVER 3 CHASSIS 8 IRON BOTTOM CAP SOLEPLATE ASSY 1 Remove Screw A1 Remove INLAY 10 Remove Screw B1 Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove IRON PCBA 6 Screw C1 C2 C3 TRIGGER SPRING SCREW CAP TRIGGER 9 Screw D1 IRON BOTTOM CAP RUBBER CAP DECO PLATE ...

Page 3: ...OTTOM HOSE GUIDE ASSY 12 STAND TOP ASSY 21 FILLING DOOR BUTTON FRAME ASSY 24 HOSECORD CLAMP HOSECORD 7 PCBA 25 PUMP ASSY 14 Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove TRAY CAP Screw A1 A2 TRAY RUBBER Screw B1 B2 TRAY Screw C1 C2 LOCK ASSY Screw D1 D10 STAND BOTTOM CAP 13 STAND BOTTOM HOSE GUIDE ...

Page 4: ...3 14 15 16 4239 021 98544 4239 026 63841 4239 021 83081 4239 015 61103 4239 015 61092 Stand Bottom Hose Guide Assy Stand bottom cap Pump Jiayin Mounted Assy Tube pump inlet Tube pump outlet Purple JYPC302 17 21 4239 010 13341 4239 021 98301 Hose clip Stand top Assy HE Purple 23 24 25 26 36 2422 070 98635 4239 021 83101 4239 021 90574 4239 021 85092 4239 021 83153 Mainscord BR 16A 1M82 Power button...

Page 5: ...RI7035 34 5 10 C1 D1 G1 E1 A1 F2 F1 H2 H1 J1 J2 E2 C2 C3 B1 11 3 5 9 10 8 4 1 6 Exploded view Iron 36 7 CSW 07 081 18218 Iron Bottom Cap ...

Page 6: ...RI7035 34 6 10 C1 C2 E1 E2 G1 F2 F1 A1 B1 A2 B2 D2 D3 D5 D6 D4 D10 D8 D9 D7 D1 25 7 16 13 12 Tray Cap Filling Door Tray 21 24 14 15 Front Lock Assy Exploded view Stand CSW 07 081 18218 ...

Page 7: ... 0 5W 2001 NOPOP 100nF 275V MKP 10 2004 330µF 10V RE 20 2003 100µF 63V RE 20 2005 330µF 10V RE 20 3005 10k 0805 5 3006 100k 0805 5 3008 0R 1206 3010 100k 0805 5 3009 4k7 1206 5 3007 10k 0805 5 3004 22R MF 5 0 5W 7002 PBSS8110T 7003 BC846B 7004 BC856B 7001 BSS84 3013 47k 1206 5 8006 BAS16 4001 201N 1A H C 24VDC 3014 100k 0805 5 3012 47k 0805 5 3027 1k 0805 5 3011 47k 0805 5 Iron LED STAND IRON Powe...

Page 8: ... Deg C Materials for example Test point Minimum Maximum 120 143 All fabric types 2 Leakage current Check that leakage current is within IEC requirement Measure leakage current between LIVE NEUTRAL EARTH IEC requirement is that at 230 V supply the EARTH leakage current must be less than 0 75 mA 3 Water leakage Functionality Check that there is no water leakage from any part of product during operat...

Page 9: ...8 Pump Cleaning restrictor Service center to perform pump restrictor cleaning via following step if observe pump not pumping water 1 De assemble water tube of pump 2 Clean restrictor via sharp object 3 Re assemble stand CSW 07 081 18218 ...

Page 10: ...RI7035 34 10 10 History record CSW 07 081 18218 ...