GC2510

3-5

REPAIR INSTRUCTIONS

-  Due to the high wattage of the iron, only the specified cord set must be used.

-  Should damage be observed on the 

CORDSET 20

, it must be replaced.  

Continued usage is not allowed.

-  After the product has been repaired, it should function properly and has to meet the safety requirements & legal regulations as 

laid down & officially established at this moment.

-  The following tests are common checks that are conducted on a repaired product before it is returned to the consumer.

1. 

Soleplate temperature

Check that soleplate temperature is within IEC requirement.

Measure the temperature of the soleplate after the iron has reached steady state i.e connected to the mains for at least 15 minutes. 
The table below shows the temperature requirement.

Marking

Soleplate temperature (Deg C)

Material, for example

Test-
point

==

Minimum Maximum N Tolerance

 (1 

dot)

  70

120

  95 ± 25

Acetate, elastane, polyamide, polyproylene

••

 (2 

dots)

100

160

130 ± 30

Cupro, polyester, silk, triacetate, viscose, wool

•••

 (3 dots)

140

210

175 ± 35

Cotton, linen

2. 

Leakage current

Check that leakage current is within IEC requirement.

Measure leakage current between LIVE/NEUTRAL & EARTH.
IEC requirement is that at 230 V supply, the EARTH leakage current must be less than 0.75 mA.

3. 

Water leakage / Functionality

Check that there is no water leakage from any part of the product during operation.

Check that the functionality of the product (product dependent) eg. steaming, variable steam, SOS, ASO etc is working properly.

4. 

Loose part

Check that there are no loose parts eg. extra screw in the product that can cause short-circuit or product malfunction.

Summary of Contents for PowerLife GC2510

Page 1: ... should function properly and has to meet the safety requirements and legal regulations as officially laid down at this moment TECHNICAL INFORMATION Voltage 110 V 220 240 V Frequency 50 60 Hz Power 1300 W 1830 2150 W Dimension F box 303 L x 120 W x 152 H mm Product weight 1 2 kg Water Advice Suitable for tap water use Advice to mix with equal portion of distilled water or use only distilled water ...

Page 2: ... catch of INLAY 15 Disassemble INLAY 15 SOS KNOB 13 SPRAY KNOB 14 PUMP ASSY SOS 11 PUMP ASSY SPRAY 10 TANK SEAL 9 THERMOSTAT DIAL PRINTED 19 Disassemble SOS KNOB 13 Disassemble SPRAY KNOB 14 Disassemble PUMP ASSY SOS 11 Disassemble PUMP ASSY SPRAY 10 Disassemble TANK SEAL 9 Disassemble THERMOSTAT DIAL PRINTED 19 WATERTANK ASSY 7 PILOT LAMP COVER 5 THERMOSTAT BUSH 4 COVER 3 RYTON RING 2 DOSING SOS ...

Page 3: ... minutes The table below shows the temperature requirement Marking Soleplate temperature Deg C Material for example Test point Minimum Maximum Nominal Tolerance 1 dot 70 120 95 25 Acetate elastane polyamide polyproylene 2 dots 100 160 130 30 Cupro polyester silk triacetate viscose wool 3 dots 140 210 175 35 Cotton linen 2 Leakage current Check that leakage current is within IEC requirement Measure...

Page 4: ...0 4239 021 35560 4239 021 33970 4239 000 08850 4239 000 08380 4239 000 08660 4239 000 08550 4239 021 34740 4239 021 38700 4239 026 23990 4239 026 25260 Soleplate assy 230 V Ceralon Soleplate m a 110 V Ryton ring Cover non Drip Stop Thermostat bush Pilot lamp cover Lamp assy Water tank assy Water tank assy 110 V Plastic rattle spring Tank seal Pump assy Spray 1 2 cc Pump assy SOS Dosing SOS seal SO...

Page 5: ...GC2510 5 5 EXPLODEDVIEW 20 5 19 17 18 22 6 4 1 3 13 14 8 7 2 12 9 15 27 21 16 11 10 B1 E1 E2 E3 A D1 D2 C1 C2 B2 ...

Reviews: