GC6259

PARTS LIST & EXPLODED VIEW - STAND

27

38

22

29

31

21

32

25

26

30

23

A

A

A

A

28

24

5-5

Pos

Service code

Description

21
22
23
24

25

26

4239 021 20000
4239 021 20270
4239 015 55310
4239 015 55280

4239 000 09150
4239 000 09260
4239 021 20040

Safety cap assy
Complete tray
Tray rubber foot
Boiler rubber foot

Intermediate supply cable (Europe)
Intermediate supply cable (Italy)
Boiler assy welded

Pos

Service code

Description

27
28
29
30

31
32
38

4239 010 08870
4239 017 08810
4239 021 20260
4239 026 16030

4239 015 55350
4239 015 55300
4239 017 09151

Electrovalve
Main switch
Superior stand
Inferior stand

Back support rubber
Filling hole gasket
Tefl on ring

Summary of Contents for Provapor GC6259

Page 1: ...fety Information This product meets the requirements regarding interference suppression on radio and TV After the product has been repaired it should function properly and has to meet the safety requirements as officially laid down at this moment TECHNICAL INFORMATION Voltage 220 240 V Frequency 50 60 Hz Power consumption Iron 800 W Boiler 1200 W Pressure 3 0 bar Dimension F box 41 x 38 x 20 cm We...

Page 2: ...CE INTERMEDIATE CABLE 7 SWIVEL 8 THERMOSTAT BUSH 9 disassemble DIAL 1 remove screw A remove connection remove hose disassemble BACKPLATE 2 disassemble INLAY 3 IRON LAMP 4 MICRO SWITCH 5 remove screw B 3x disassemble IRON HANDLE 6 REPLACE IRON SKIRT 10 SOLEPLATE UNIT 11 disassemble DIAL 1 remove screw A remove connection remove hose disassemble BACKPLATE 2 disassemble INLAY 3 IRON LAMP 4 MICRO SWIT...

Page 3: ... 12 4239 021 20720 4239 026 16310 4239 026 16320 4239 017 08940 4239 017 08950 4239 021 20730 4239 021 20700 4239 026 15580 4239 015 98410 4239 026 16340 4239 021 20710 4239 026 16350 Dial Backplate Inlay Iron Lamp Micro switch Iron Handle Intermediate cable micro switch Swivel Thermostat bush Iron skirt Soleplate unit Electrovalve trigger ...

Page 4: ...e careful of the sharp edges of the stainless steel tray assy a thick glove when removing the tray assy To avoid damage to the sealings and components of the boiler NEVER clean the boiler with vinegar descaling agent or other chemicals Apply loctite to the screws on the boiler heating element upon any unscrewing screwing operation The boiler is required to be rinsed after every 10 times usage ALWA...

Page 5: ...4239 021 20040 Safety cap assy Complete tray Tray rubber foot Boiler rubber foot Intermediate supply cable Europe Intermediate supply cable Italy Boiler assy welded Pos Service code Description 27 28 29 30 31 32 38 4239 010 08870 4239 017 08810 4239 021 20260 4239 026 16030 4239 015 55350 4239 015 55300 4239 017 09151 Electrovalve Main switch Superior stand Inferior stand Back support rubber Filli...

Reviews: